BLOWER DOOR T95T FORM
SCANNED House infiiteaVon Test Cwtreicati®n
BY - Prescriptive and Performance -Method
Lurie C MY .
. I t Permit #:
S'
(3 o $ - 0 2(1 ,
Address:
c ,nstruc'tion- New. Consteucti n — Complete � . � Existing -:-After AddRion
H'FUse Infiitration Test Result SLC Climate Zone 2 q
C, m (50) ;_ 1 0 b - 'rest Date:
V fume = i 3 26 2 _
A- H (50) = CFM (50) x 601 Volume T � >6 lidechanical Verrt'ilation required less than 3 ACH
P 'lssing results PB ust be & ACH (50) or less (�J} Pass ( ) Fail
PAGE 02/02
1✓f3 irnerg°� .
Tip building or dwelling unit shaIt' be tested and verffled as having an air leakage rate of not exceeding 7 air changes per
ho in.Cllmate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
bl•o er door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Sec Ion 553.993(5) or (7),, Florida Statutes or individuals licensed asset forth in Section 489.105 (3)(f), (g) or (1) or an
app, oved third party. A written report of the results o•fthe test shall be signed by the party conducting the test and
pro 'lided•to the code official_ Testing shall be performed at any time after creation of. all penetrations of the building
the al envelope.
Wh
FSC� i2msdde�o4ia f
the air infiltration rate of a dwelling unit is less Than 3 air changes per hour when tested with a blower door at a
Ares' fire of 0.2' inch w.•c_ (50 Pa) in accordance with Section R402.4,.1.2 of the Florida Building Code, Energy Conservation
the lweliing unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Com any Name• Pro"DUGt.Sefvices Address: 1915 trio Vista Drive, Pt.'Pieroe, Fl. 34949
l her Ilby certify that the above House infiltration results demonstrate compliance with FBC Energy Conservation
requilliements in accordance with $action R402.4.1.2'Climate Zone 2.
re:
Name: Martin Klein .
cation #: 5061633
1
10 10/2019 12:42 77246AF?56 BEAN DRYWALL,INC. PAGE 01/02
Plannin
�: • '•J . •� • - , � g & i�eveilOprne�tt services .
Buildl!i, & c�
Regulation $ de �ltlP5it3rt
2300 Virginle Ave, prn 2.01
FOrt MUM FL 34982
Pliona' 772-462-2165 Fair: 772-462-644.70
J
SLOWER DOOR.TI ES 7 FORM
Hawse OnflitrratIO' s Test Certi leaf oa n '
PreSC Ptive and Pedorrmailce Method
Address;
;° �,� � a�se� sida�I���rra���a�� �- ����Ue>y� ' � � ��tastai~dg-._,A�ec• Ad�ii�Bcat�
I"' use Infiltration Test € esults
PA (50) = q.o 9 Sf.0 t:Jisxiaie Xont 2
F(-I (5O) = CFM (50) it 601 VolumeMechanicOl VenYllc7dan required less t'haan 3,!+Ct-1 ;
sshIg aestaits must be & ACJJ (sD) of ISss . t✓) pass � ) Fail
building or dvdellin$ unit shall be tested and verified as having an air rea!<age rate or not exceeding 7 air changes per
ho r in Climate Zone 1, 2 and 3 air changes per hour In Climate zones 3 through 8. Testing shalt be conducted with a
bl %der door at a pressure of 0,2 inches w. g. (5o pascals). Testing shall be conducted by either individuals as defined in
Se �fon 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) pr (1) or an
ap droved third party. A written report of the results of the test shall be signed by the party conducting the test and
pr ided to* the code official, Testingshall b@ performed at any time after creation of all penetrations of the building
the, Mal envelope.
513Ir Residentiar
wh re the air infiltration rate of a dwelling unit is less than 3 air changes pel• hour when tested with a blower'door at a
pre sure of 0.2 inch w. e. (50 Pa) In accordance with Section R402.4.1.2 of the Florida Code, Energy Conservation
the welling unit shaii be provided with; whole -house mechanical ventilafian in accordance with Section M1507.3.
Cortpa.ny Name: Pro -Duct Service
Address: '1915 Rio Vista Drive, [=t. fierce, FL 3d949
i he'eby-certifyrthat the above House Infiltration results demonstrate compliance with FSC Energy Conservation
reqt 'srements in accordance with �§ectlR�402.2 Climate Zone 2.
Sign ture:•
Prrn red Name: '1 ar tin Klein
Lice; se/Certification #; 5ti6� G3$