Loading...
HomeMy WebLinkAboutREVIEW-COMMENTSr ��4 ' \ i III ,-� :Iw4e,c Play, ning & Development Services ����M� Bui1. ng&Code Regulation Division. BY REVIEW COMMENTS 2300 Virginia Avenue ` t. L ude �+�0?un. t% i Fort Pierce, P.L 34982' �I Phone772)462-2172 Fax:(772J462-6443 Page 1 PROPERTY INFORMATION I � Addres 257 - 259 Dixieland Dr. Owner(s): I Oleander Properties Dixieland Llc II City / S4' to /Zip: Fort Pierce, FI 34982 I i j Parcel # 2427-801-0087-000/9 Jurisdiction: SAINT LUCIE COUNTY II Zoning: RM-11 Lot#: 3 Block: 7 APPLIC TION INFORMATION II Permit NISI tuber: 1808-021.9 Stories: Automatic Sprinkler System? No Permit T e: MULTI -FAMILY RESIDENTIAL CONTR CTOR INFORMATION I Contract Name: Brian P Bean Fax Number: i Business ame: Southern City Development Inc it Business'' ddr: 6011 Buchanan Dr Email: Brian_Bean@Yahoo.Com I' City / Stat' / Zip: Fort Pierce, FI 34982 I REVIEW AND COMMENTS Review TvD Status Reviewed By Date Com leted Date Released I Date Started A , ADDRESSIN , ASSIGNMENT COMPLETE Lori Bender 9/14/2018 9/14/2018 9/14/2018 I i I Comment: I 'I DOCUMENT MISSING PENDING Karen Nielsen 8/8/2018 8/8/201 Comment: SENT TO ERD WITH VEG PERMIT 9/12/20 Comment: PLEASE SUBMIT A DRIVEWAY PERMIT APPLICATION FOR THE CONNECTION TO DIXIELAND DR. I ENVIRONME TAL REVIEW INCOMPLETE Lynn Swartzel 8/9/2018 9/25/20I Comment: PER MAYTE. PUT ON HOLD UNTIL WORK OUT ISSUES WITH CONSTRUCTABILITY REVIEW. FRONT COU ER REVIEW COMPLETE Karen Nielsen 8/8/2018 8/8/2018 81812018 Comment: I PERMIT ON H LD COMPLETE Lydia Galbraith 8/2212018 9/12/2018 9/12/2018 II Comment: PLANS EXAMI ER REVIEW INCOMPLETE William Durden 9/21/2018 I i Comment: CLASSIFICATION OF THE PROJECT SPECIFIES TOWNHOUSE ON PAGE A-121A. PLEASE SEE DEFINITION OF TOWNHOUSE. PLEASE RECLASSIFY. I 9/25/2018 [RB] TOWNHOUSE: A SINGLE-FAMILY DWELLING UNIT NOT EXCEEDING THREE STORIES IN HEIGHT CONSTRUCTED IN A GROUP OF TWO OR MORE ATTACHED UNITS WITH PROPERTY LINES SEPARATING SUCH UNITS IN WHICH EACH UNIT EXTENDS FROM FOUNDATION TO ROOF AND WITH AYARD OR PUBLIC I WAY ON NOT LESS THAN TWO SIDES. Comment: PLEASE SUBMIT THE ROOF UNDERLAYMENT MEETING THE REQUIREMENTS OF THE.GAF ROOFING 9/25/2018 PRODUCT APPROVAL NUMBER FL10124.1 -R20, LINE 6.1.1. I I i ling & Development Services ig & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 '72)462 2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 18 Comment: PLEASE REMOVE OR STRIKE THROUGH WITH DO NOT USE TO ANY REFERENCE'S TO THE 3 UNIT STRUCTURE. PLEASE SEE CHAPTER 1, SECTION 107, SUBSECTION 107.2.1. Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 18 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61 G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. 18 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2017 FLORIDA BUILDING CODE. Comment: - • THE TRUSS ENGINEERING MUST HAVE THE ORIGINAL SIGNATURE OF THE TRUSS MANUFACTURER'S ENGINEER. REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL IN CHARGE. PLEASE CORRECT 8 AND SUBMIT IN DUPLICATE. IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. AND CHAPTER 8 SECTION R802 SUBSECTION R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: SEE SOIL AND FOUNDATION NOTES ON PAGE S-001. PLEASE SUBMIT A COPY OF THE GEOTECHNICAL 8 REPORT SPECIFIED ON LINE SF-1. REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL. SEE SECTION 107.1 OF THE 2017 FLORIDA BUILDING CODE. 8 Comment: PLEASE PUT ON THE PLANS THE SOIL DENSITY OR SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE WITH R401 OF THE 2017 RESIDENTIAL BUILDING CODE. 8 Comment: ! PLEASE SHOW FLAME SPREAD INDEXAND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA RESIDENTIAL CODE. 8 Comment: • PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2017 FLORIDA RESIDENTIAL CODE. 8 Comment: • PLEASE ADD TO THE PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN CRIERIA WEATHERING AND TERMITE AREA IN ACCORDANCE WITH TABLE 301.2.(1) 8 Comment: • ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION 405.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE. Comment: 18 Comment: 18 Comment: 8 Comment: 8 Comment: 8 Comment: 8 Comment: 8 Comment: 8 Comment: 8 8 Comment: Comment: 8 • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES AND SIZES OF GLAZED OPENINGS ON PLANS. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA . BUILDING CODE ENERGY CONSERVATION 6TH EDITION. • LINE THREE ON THE ENERGY CALC'S ARE INCORRECT, STRUCTURE IS A MULTI -FAMILY UNIT. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. • LINE FOUR ON THE ENERGY CALC'S ARE INCORRECT, INCORRECT BED ROOM COUNT. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. • LINE SIX ON THE ENERGY CALC'S ARE INCORRECT, INCORRECT SQUARE FOOTAGE. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. • LINE TEN ON THE ENERGY CALC'S ARE INCORRECT, PLANS CALL OUT R-30. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. • LINE FOURTEEN ON THE ENERGY CALC'S ARE INCORRECT, WATER HEATER SIZE DOES NOT MATCH THE PLANS. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH EDITION. • SEE THE ROOF SECTION ON PAGE 2 OF THE ENERGY CALC'S FOR THE ROOF MATERIAL. ENERGY CALC'S AND PRODUCT APPROVAL AFFIDAVIT DO'NOT MATCH. PLEASE CORRECT. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. • SEE THE ATTIC SECTION ON PAGE 2 OF THE ENERGY CALC'S. ENERGY CALC'S AND PLANS DO NOT MATCH. PLANS SHOW A VENTED ATTIC. PLEASE CORRECT. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. UNABLE TO COMPLETE MY REVIEW OF THE ENERGY CALC'S DUE TO MULTIPLE DISCREPANCIES FROM THE PLANS TO THE ENERGY CALC'S. PLEASE REVISE AND SUBMIT FOR REVIEW. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. INCORRECT ADDRESS ON THE PLANS. PLEASE REVISE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. I 4 i \ 1 f I Pi, ning&Developmentservices. REVIEW COMMENTS Bulii Ing & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:' (772)462.2172 Fax:(772)462-6443 Page 3 ZONING REVIEW INCOMPLETE Lydia Galbraith 9122/2018 Comment: PLEASE PROVIDE 2 SIGNED AND SEALED BOUNDARY SURVEYS INCLUDING BUT NOT LIMITED TO THE EXISTING GRADE ELEVATION ON THE LOCATIONS OF CONSTRUCTION, THE ELEVATION OF THE CROWN 9/ 2018 OF THE ROAD AND LEGAL DESCRIPTION. SEE FOR COMPLETE BOUNDARY SURVEY REQUIREMENTS ST LUCIE COUNTY LAND DEV. CODE CHAPTER 11.02.09 (2-D). 9/ /2018 Comment: PLEASE INDICATE THE AREA OF CONSTRUCTION COVERED, UNDER THIS PERMIT ON THE PLANS Comment: PLEASE REMOVE PARCEL ID 2427-801-0090-000/3 FROM THE PLANS. THE LOTS 3, 4, 5 AND 6 HAVE BEEN 9/ 2018 COMBINED UNDER PARCEL ID 2427-801-0087-000/9. 9/ /2018 Comment: PLEASE CORRECT NOTE 1, NORTH AMERICAN VERTICAL DATUM IS NAVD AND NOT NGVD. 9/ 2018 Comment: PLEASE INDICATE THE DIMENSION OF THE STRUCTURES ON THE SITE PLAN. 9/ 2018 Comment: PLEASE NUMBER THE BUILDINGS ACCORDINGLY. Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW. THE PLANS 9/ 2018 EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.