Loading...
HomeMy WebLinkAboutMULTI-WIDE TIE DOWN PLACEMENT SPECIFICATIONSI I ii ❑ ❑�S -v N NOTE: tHE FOUNDATION/PIER SYSTEM IS DESIGNED TO RESIST FLOOD ELEMENTS OF FLOTATION, COLLAPSE AND LATERAL MOVEMENT PER FEMA CRITERIA FOR EXPOSURE I'D" LOCATIONS. 3'-0.. TO VENT II L la TO T«- SCALE: 1/4 = I 0 a TO C56 BLOCK ,um !R3115111 A MINIMUM OF 4" OF CONCRETE FLATWORK BETWEEN MODULAR UNIT 4 PROPERTY LINE. (NOT TO EXCEED PROPERTY LINE.) -- --_.F -- - F . ----F- ---- - , I , , fl I fl , r -F— TO VENT OWN/PIER REQUIR E1'*o1ENT5 PER 3222.2. (1) 50. IN. FOR EACH Sa FT. OF ENCLOSED AREA. EACH VENT COVERS 221 50. FT. PER PRODUCT APPROVAL. 1081 Sia FT. / 221 ■ 5 VENTS Will T I -BEAM PART 05SO02 FRAME ATTACHMENT FOR FACTORY BRACKETS STRAP/SWIVEL CONNECTOR SOME HOMES MAY HAVE FACTORY BRACKETS WELDED TO THE I -BEAMS FACTORY FOR LONGITUDINAL ANCHORS. ATTACH THE STRAP/SWIVEL CONNECTOR TO $RA 4 eT THE FACTORY BRACKETS USING A J" GRADE 5 BOLT 4 NUT. ANCHORS/TIES MUST BE INSTALLED TO PROVIDE A 459 OR LOWER STRAP ANGLE. 4" 6'-2" 6'-2" 6'_2" =XfB ING 4" CONCRETE SLAB (3000 PSI) OVER 6" X 6" X 10/10 W.W.M, OR FIBRE MESH OVER 6 M L POLYETHYLENE VAPOR BARRIER OVER CLE N, POISONED, COMPACTED (TO 2500 PSF OR 851/6 DENSITY) FILL. m� 3'-ID" TO VENT STRUCTURAL NOTES: SOIL BEARING CAPACITY MIN. 2500 PSF ALL STRUCTURAL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE STRENGTH OF 2500 PSI AT 2S DAYS. ALL REINFORCING STEEL SHALL BE GRADE 60 MEETING ASTM SPECS A-615 MIN. CONC, PROTECTION FOR RE -BARS: FTGS: 3" BEAMS: 0i2" SLABS: I" LAP REINFORCING BARS 30 INCHES MINIMUM EX_POSIIRF "C" - 110 MPH 3 SEG Gill I I z� O� Q I Q LLI ZW ATTACHED W/ (2) fl0x3' GALV DECK SCREWE AT EACH BEARING POINT - UNIT Wt 360 LBS. 353 C/FT 2X6 SYP STRINGEF CONDENSING U41T (2) Yell' GALV LAG SCREWS SIMPSON LU25 AT STAIR STRINGERS TO 2X8 DECK JOIST SUPPORTS OR t• (2) gV GALV LAG SCREWS SIMPSON MSTC52 AT STRINGER TO POST SXI6 BLOCK 4 COURSE 4X4 PT POST W/ SIMPSON AB44 N � CONCRETE \ r v ��a m W C2) 0I4 SHEET METAL W SCREWS TO C0N0EN51WG; CI)Ya" X 24" LG. TAPCON PER BLOCK UNIT. 200 LB. SHEER - U N 4 (2) AT CONCRETE: IW LE.5. WORDING CAPACITY V - PROVIDE 3OX3ID ACCESS A/C TIE -DOWN DETAIL DOOR TO VENT 2 2X6 SYP DECK w��t�C JOISTS m Ib" OC NOTES: LENGTH VARIES AT COMPOSITE DECKING 2-GALV. BOLTS g/g"-11 X 2 V4" LG, ATTACHED W! C �WS GALV DECK SCREWS AT EACH BEARING POINT TENSION BOLT LABELED (A) FOR FRAME ATTACHMENT ONLY, TENSION BOLT LABELED lB) FORSIMPSON M?512 SIMP50N FACE MOUNT VERTICAL TENSION. 4 HANGER LU26 $ B-BOLT /- 5/8"-11 X 2-3/4" JOIST SUPPORT W/ 2X0 SYP DECK STRAP W Q UJ (2)" GALV LAG SCREWS N = 5*'x1" WEDGE ANCHOR (RED HEAD) I I LJ M I C52 ANCHOR BY: TIE DOWN ENGINEERING MAX UPLIFT PER 2X SYP - DEVICE IS 4,150 LBS TIE DOWN STRAP - PER SPECIFICATIONS 1-BEAM s all Xail X16"- CBS BLOCK PIERS 4" SLAB W/ RB SEE T E OiiA�l/ (� -8 GALV SCREWS _oNORETE J- { (2) EACH SIDE " WEDGE ANCHOR L 4X4 SYP POST ATTACHED TO GONG W/ 3" EMBEDMENT MIN W/ SIMPSON 4544 POST BASE DECK CONNECTION DETAIL DEC< FRA1„IIlilli SCALE: 1/2" = 1'-0" SCALE: 1/4" 1'-0" UNIT TO BE TIED DOWN PROVIDE (2) 05 X 24, !� DECK SCREWS TOE -NAILED AT EACH VERTICAL MEMBER OF KNEE WALL ` WALL COMPLIES WITH UNIT MANUFACTURER'S PERIMETER � WALL BLOCKING REQUIREMENT I HYDRO VENT SEE PLAN 2X4 P.T. SYP KNEE WALL W/ STUDS o 16" OC _JZW/Y4"x3" TAP -CONS 9 24" OG (BOTTOM PLATE) W/ r:" CDX PLYWOOD W/ 5/6" W/ VINYL LAP SIDING 4 TYPICAL ELEVATION l ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ (l D L } N.T.S. (FOR VISUAL PURPOSES ONLY) PIER REQUIREMENTS O _________________ r��'- -- __________________ -- _ --1,� ---- A < EXTERIOR FINISH -u L1 = -------- - ,t---------------- ' ���------------ -------- Eli- - f�- fE:;------ ---------- �' J -�= ■ I- 0 --, ® ED E CONCRETE HIG0NRB C NTE MICS2 ANCHOR 5/e"x"' WEDGE a'D X a"W W (SEE DETAIL) ANCHOR (RED HEAD) CAULKING PROVIDE Y)" MACHINE BOLT THRU I -BEAM 6' 0" W/ (2) TIE DOWN STRAPS SWIVEL CONNECTOR OR LESS WITH RADIUS CLIP (2) MICS2 ANCHORS AT CONCRETEAS /` fin` SECTION SHOWN J""t lam' (SEE E DOWN ENGINEERING FOR DETAILED INFORMATION) Q o- SCALE: 3/4i e I _IDii u r - ------- =---- ------- ��-- ---C -- WEND AGAINST FACE OF UNIT: ' ---- -rT- �,j l� - - tr- ---- EJ------------------- TS 2XI2 SYP STRINGER 2XI2 SYP STEP IXS SYP W/ DECK SCREWS Nil" X 3" GALV. HEX SCREWS 4-REQ'D. R NGLE APCONS _ TREAD . I" NOSE STAIR DETAIL N,T.S, PROVIDE (3) 010x3" DECK WS AT EACH 2X6 SYP DECK 2X6 SYP DECK FJOIST6)�ANLEDG2X6 5YP STRINGER JOISTS o 16" OC 2X COMPOSITE DECKING 2XS SYP - ATTACHED W/ STRINGER GALV DECK SCRR EWSW$ � '�, AT EACH BEARING POINT 4'-1 z_ E M n A' SEE STAIR DETAIL 4X4 $YP- POST RIPPED 4X4- SYP BLOCKING FOR 2X6 5YP ANGLED 9TRINC 91O 2X6 SYP ANGLED STRINGER TAI 6 - - - — - r 0 MID WOOD SCREW - o - — o _ -�� ❑ - ❑ r--, ❑ ❑ -,,625 x 46 10.2 SCE. FT. x 45 P.SF. = 459 L8. UPLIFT (3) PER SIDE r -,J - - — '�,-++ - - - - - - ,� — - - — - - -- - - ` , 144 THRI,I FRAME TO WGOD FRAMING ❑ ❑ "' ❑ ❑ " ❑ ❑ 45S - 360 LB, UNIT JS LBS. UPLIFT ASSUMING EQUAL LOAD DISTR, MIN IS" EMBENDMENT TAPCON WILL HOLD 160 S. AN 2 SCREWS WILL HOLD 200 S. _________________ _________ ___ __________ ________________ '_;" ------ --- LL LD LB D RE L LBXTRIOR DOOR _ - - --------- AT EACH OF THE 4 CORNERS. _.,�_______1��T_________________�_��_____---__-_---_-y. _____________________________ __ �F1___ ____________ .�._______ >rJ _____ (METAL FRAME) �_, , .o 4:9- THEREFORE STRAP, TAPCON AND SCREWS WILL HOLD UNIT IN PLACE. PROVIDE �" MACHINE BOLT THRU I -BEAM PROVIDE �" MACHINE BOLT THRU I - SEAM A 4" SLAB, 42" X 52" WEIGHS -I85 LBS. 0.1 W/ (2) TIE DOWN STRAPS SWIVEL CONNECTOR W/ (2) TIE DOWN STRAPS SWIVEL CONNE TOR OR L R LESS WITH RADIUS CLIP (2) MIC62 ANCHORS AT CONCRETE WITH RADIUS CLIP (2) MICS2 ANCHORS AT CONCRETE 6 -0 OR LESS AS SHOWN ASS OWN O (SEE TIE DOWN ENGINEERING_ FOR DETAILED INFORMATION) (SEE TIE DOWN ENGINEERING ER DETAILED INFORMIA ION) O --------------i'-�L----------------- ,----------------- �'--------------- ------------------��T---------------- ?��`-------► -_j -------- ALL LU 5ER &HALL 5E 6"1 PRE55URE TREATED _ _ __ _ _ ----------------- -- ---- ALL MATERIAL 5ELOW BLOOD MUST PE CONSTRICTED WITH FLOOD RESISTANT MATERIAL, IN ACCORDANCE WITH tYP Mlll tl-WIDE tIE-DOWN PLACE ENT E° SECTION R322 OF THE 2011 RESIDENTIAL BUILDING CODE. SCALE: 1/4" = 1' I ST. Lucie County, Permit-ti.„ " HAIL BRACKETS OR BALUSTERS SHALL NOT BE CONSIDERED TO BE OBSTRUCTIONS TO GRASPABILITY. SCANNED 50TTOM OF HANDRAIL SHALL CONTINtV gp BY TO SLOPE FOR A DISTANCE OF THE 1)EP�Tl=7�"por4m* OF ONE TREAD FROM BOTTOM RISER HANDRAIL HAS CIRCULAR CROSS-SECTION ROTE,W/ I1- XV TO 2" DIMENSION. GUARDRAIL SHALL COMPLY W/ FBC - 5TH ADDITION W■ ■'' 2-410 X I" NON -CORROSIVE N� 5M.S. e EACH PICKET POST -� I CONNECTION. PICKET TOP PLATE TO P057 < POST TO CHANNEL W/ _L4_LL 010 X W- ,, S.M.S. H,4ND SAIL DETA1L N.T.S. VINYL 2X2 RAIL POST MOMIN. ATTACHED TO VINYL EMBEDMENT. CASTERS 4-REQ'D, ay rt 1 Ya" S.S.S. MIN. I" EMBEDMENT. C 4-REQ'D. 2X6 SYP 2X6 SYP DECKING STRINGER MAILING 5 5E N.T.S. THIS SETUP HAS BEEN DESIGNED FOR A FLOOD ZONE INSTALLATION DESIGN CRITERIA PER FBC - 2011 6TI4 EDITION FREt,P REVISIONS BY PER BLDG. JB DEPART, S/5/I5 PER BLDG. JB A / H � o 0 � o N � Y rory �M y + o& V � r zw� O w mu �o� V S c W �0 W d� pill Ill W Z O 0�1 F, w Fi w �ry r ps Q - ' 03 m y, mw o� oLij Y z mL o in u z HE--,� 0 U L M w `4 O wopo U w U �33 Of wwLo w �`rCau�i U Y-� E P4 f� O W Iw1 I-� M W a � A w A 00 z 2� w Im R Z W Ell O Date: 07-11.201a Scale: I/4" - v-v Drawn: MM/BGM .IO b: 5 STAR LOWREY Sheet: .f Sheets ►E- J