Loading...
HomeMy WebLinkAboutREVIEW-COMMENTSi Pla. IngBDevelopment Services SCANNED REVIEW COMMENTS Build fig & Code Regulation Division. �� 2300 Virginia=Avenue Fort Pierce, FL. 34982 Phone: i II 72)462-2172 Fax:(772)462-6443 i City / St Parcel # Zoning:) / Zip: Permit umber: Permit pe: CONTR CTOR 1 Contract) r Name: Busines- Name: BusinesI Addr: City/Sta/Zip: 1f1 FRONT Page 1 3136 Brocksmith Rd Owner(s): Tabitha Smith Hester Fort Pierce, FI 34945 2329-502-0006-000/9 Jurisdiction: SAINT LUCIE COUNTY AG-5 Lot#: 6 Block: WATION 1808-0584 Stories: Automatic Sprinkler System? No BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) IMATION John A Groza Fax Number: 772-336-2272 Groza Builders Inc 511 Sw Port St Lucie Blvd Port St Lucie, FI 34953 Email: John@Grozabuilders.Com. g g g g g 8 Status Reviewed By Date Started Date Completed Date Released ASSIGNMENT COMPLETE Lori Bender 8/29/2018 8/29/2018 Comment: MISSING PENDING Deanna Givens 8/22/2018 I Comment: NOTICE OF COMMENCEMENT I Comment: 8-31-18 VEG PERMIT IN DRAWER UNDER (II) FOR HESTER NO FEE VEG PERMIT SENT TO ERD Comment: FILLED LANDS AFFIDAVIT Comment: PLUMBING SUB AGREEMENT Comment: HVAC SUB AGREEMENT Comment: ROOFING SUB AGREEMENT Comment: ELECTRICAL SUB AGREEMENT Comment: A COPY OF THE PAID UTILITY SERVICE RECEIPT FOR ELECTRIC SERVICE OR A LETTER FROM THE ELECTRICAL UTILITY PROVIDER THAT ELECTRIC WILL BE AVAILABLE TO THE LOCATION. TAL REVIEW COMPLETE Lynn Swartzel 8/27/2018 8/29/2018 8/29/2018 Comment: rER REVIEW COMPLETE Deanna Givens 8/22/2018 8/22/2018 8/2212018 Comment: t7-Gtii �O�t PLANS ling & Development Services ig & Code Regulation Division. 2300 Virginia Avenue Fort Pierce, FL.. 34982 '72)462-2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 MINER REVIEW INCOMPLETE William Durden 9/1/2018 Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING 118 THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 118 Comment: • THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW ENERGY CALULATIONS WITH ORIGINAL SIGNATURE PER 107.1 OF THE 2017 FLORIDA BUILDING CODE Comment: • SEE THE ROOF SECTION ON PAGE 3 OF THE ENERGY CALC'S FOR THE ROOF MATERIAL. ENERGY 18 CALC'S AND PRODUCT APPROVAL AFFIDAVIT DO NOT MATCH. PLEASE CORRECT. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 18 Comment: PLEASE SUBMIT THE CORRECTED PRODUCT REVIEW AFFIDAVIT REMOVING THE CITY OF FORT PIERCE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: TRUSS ENGINEERING NOT SIGNED BY THE MITEK. - THE TRUSS ENGINEERING MUST HAVE THE ORIGINAL SIGNATURE OF THE TRUSS MANUFACTURER'S ENGINEER. REVIEWED AND APPROVED BY THE DESIGN 18 PROFESSIONAL IN CHARGE. PLEASE CORRECT AND SUBMIT IN DUPLICATE. IN ACCORDANCE WITH 61G15- 30.005 OF THE FLORIDA ADMINISTRATIVE CODE. AND CHAPTER 8 SECTION R802 SUBSECTION R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. /IEW INCOMPLETE Lydia Galbraith 8/24/2018 18 Comment: PLEASE PROVIDE A COPY OF THE WELL PERMTI AND THE SEPTIC PERMIT FROM THE HEALTH DEP. 18 Comment: PLEASE PROVIDE 2 FLOOR PLANS AND 2 SURVEYS STAMPED FOR APPROVAL BY HEALTH DEP. Comment: THE SURVEY IS INCOMPLETE. PLEASE INDICATE THE FOLLOWING: - PROPOSED FINISHED FLOOR ELEVATION. BASED ON APPROVED SITE PLAN 24.8' OR 18" ABOVE CENTER LINE OF THE ROAD WHICHEVER IS GREATER 18 - CENTER LINE OF THE ROAD AND THE ELEVATION OF THE CENTER LINE. - DIMENSIONS OF CONCRETE DRIVEWAY, IN FRONT OF THE BUILDING. THE AREA WILL NEED TO BEAT LEAST 20' WIDE X 18' OR 10' X36' TO ACCOMODATE THE 2 REQUIRED PAVED PARKING SPACES. (ST LUCIE COUNTY LDC CHAPTER 7.06.02 AND ITE PARKING MANUAL) 18 Comment:. PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.