Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEI A �...........• �_ I �a niDe oCo R �De artment RECEIVED' i�� ivion���F--- �vti/ 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462- 553 AUG 2 4 2018 Certification for Design Load Compliance @T, 6w.Gie G@unt , Permitting Project Name: Shiffer Residence Project Address: 3803 Eleven Mile Road, Fort Pierce, Florida 34986 Permit #: Occupancy Type: R3 Construction Type: INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Residential Code Fifth Edition with 20 18 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 132 mph X ASD LRFD End Zone Width: ft 5. Mean Roof Height 15 ft Roof Pitch: 6 :12 _ Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -25.62 / 14.76 Zone 2: -43.02/14.76 Zone 3:--sz74r14.76 Zone 4:-27.78125.62 Zone 5:-43.02/23.45 Garage: 7. Design Loads: Floor: 100 PSF Roof/Dead: 10 PSF Roof/Live: 40 Balcony: n/a PSF Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: J. Scott Baruch. AIA AR0014964 Signature, Date, and Seal Revised 07/25/2014 Print Name _ Cert # & Co. Cert Auth. J. Scott Baruch & Associates, Inc. 178 Beacon Lane, Jupiter, FL 33469 Company Name & Address