HomeMy WebLinkAboutREVIEW-COMMENTSr
PlanoDevelopmentServices REVIEW COMMENTS
Buildinode, Regulation Division luJ(jvU�'f
Virginia Avenue y
ierce, FL. 3498.2
Phone:(?2-2172 Fax:(772)462-6443'a ]1Ca L^�
Page 1
PROPS Y INFORMATION
Address: 3755 Eleven Mile Rd Owner(s):
David Lloyd / Lynda Lloyd
City / Stalle / Zip: Fort Pierce, FI 34945
Parcel #: 2328-343-0000-00017 Jurisdiction: SAINT LUCIE COUNTY
Zoning: AG-2.5 Lot#: Block:
I
APPLICATION INFORMATION
Permit Nu ber: 1808-0637 Stories: Automatic Sprinkler System? No
Permit Ty e. BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
Contractgt Name: Charles D Kerns Fax Number: 772-209-7700
Business Name: Kerns Construction & Property Management Corp
Business Addr: 2701 Industrial Avenue 2 Email: Kerns02@Att.Net
City / Stage / Zip: Fort Pierce, FI 34946
Review T
'e
Status Reviewed By Date Started Date Completed
Date Released
ADDRESSING
ASSIGNMENT
COMPLETE Lori Bender 10/16/2018
10/16/2018
Comment:
DOCUMEN
S MISSING
PENDING Karen Nielsen 8/24/2618
8/24/2I
18
Comment:
ROOFING SUB
8/27/2I,18
Comment:
GENERAL CONTRACTOR ON HOLD, WILL NEED TO UPDATE LICENSE.
8/27/2Q18
Comment:
MECHANICAL SUB CONTRACTOR ON HOLD.
9/4/2
18
Comment:
VEG PERMIT FILED UNDER (L) FOR LLOYD. NO FEE.
ENVIRON
ENTAL REVIEW
COMPLETE Lynn Swartzel 8/28/2018 8/31/2018
8/31/2018
Comment:
FRONT CO
NTER REVIEW
COMPLETE Karen Nielsen 8/24/2018 8/24/2018
8/24/2018
Comment:
PERMIT ON
HOLD
COMPLETE Lydia Galbraith 8/27/2018 10110/2018
10/10/2018
Comment:
PLANS EYJ
I MINER REVIEW
INCOMPLETE Joseph Fersch 10/17/2018
Comment:
PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE
10/17/
18
SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING
CORRECTED
DOCUMENTS.
10/17/
18
Comment:
PLEASE SHOW ON THE SURVEY FLOOD LINES. 107 FBC 2017 6TH EDITION
& Development Services
Cgde:Regt tWtlon Division
0 Virginia Avenue
Pierce, FL: 34982
62=2172 Faxs(772)462-6443
REVIEW COMMENTS
2
10/17/ 018 Comment: PLEASE SHOW ON THE SURVEY THE FINISHED FLOOR ELEVATION.
Comment: PLEASE PROVIDE PER 2017 FBC 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED WITH
THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
10/18/ 018 AND LOCATION OF NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, DISTANCES FROM
LOT LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED GRADES AND, AS
APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE
DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE SURVEY
Comment: PLEASE REVISE PRODUCT APPROVAL TO REFLECT THE CURRENT FOR 17234 R1 CHAPTER 1, SECTION
10/24/I
018
107 SUBSECTION 107.1 OF THE 2017 FLORIDA BUILDING CODE
Comment: PLEASE REVISE PRODUCT APPROVAL TO REFLECT THE CURRENT FOR 1354 R1 ON RECORDS COULD BE
10124/
018
FOUND CHAPTER 1, SECTION 107 SUBSECTION 107.1 OF THE 2014 FLORIDA BUILDING CODE
Comment: PLEASE REVISE PRODUCT APPROVAL TO REFLECT THE CURRENT FOR 1654 R8 CHAPTER 1, SECTION
10/24/:018
107 SUBSECTION 107.1 OF THE 2017 FLORIDA BUILDING CODE
Comment: PLEASE REVISE PRODUCT APPROVAL TO REFLECT THE CURRENT FOR 10674 R12 CHAPTER 1, SECTION
10/241
018
107 SUBSECTION 107.1 OF THE 2017 FLORIDA BUILDING CODE
Comment: PLEASE REVISE PRODUCT APPROVAL TO REFLECT THE CURRENT FOR 5259 R26 CHAPTER 1, SECTION
10/24/
018
107 SUBSECTION 107.1 OF THE 2017 FLORIDA BUILDING CODE
Comment: PLEASE REVISE PRODUCT APPROVAL TO REFLECT THE CURRENT FOR 16703 R9 NO RECORD CHAPTER
10/241
018
1, SECTION 107 SUBSECTION 107.1 OF THE 2017 FLORIDA BUILDING CODE
Comment: PLEASE ADD THE TOTAL CUBIC VALUM TO THE AREA SECTION 107 SUBSECTION 107.1 OF THE 2017
10/24/
018
FLORIDA BUILDING CODE.
Comment: PLEASE PROVIDE DETAIL FOR THE FRONT PORCH ROOF ATTACHMENT TO RESIDENCE. SECTION 107
10/24/
018
SUBSECTION 107.2.1 OF THE 2017 FLORIDA BUILDING CODE
Comment: PLEASE PROVIDE THE SOIL DENSITY PERCENTAGE REQUIRED SECTION 107 SUBSECTION 107.1 OF THE
10/24/
018
2017 FLORIDA BUILDING CODE.
10/241
1018
Comment: PLEASE SHOW COMPLIANCE WITH R302.7 UNDER -STAIR PROTECTION FLORIDA BUILDING CODE —
RESIDENTIAL, 6TH EDITION (2017)
10/244
018
Comment: PLEASE SHOW COMPLIANCE WITH R302.9 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR
WALL AND CEILING FINISHES FLORIDA BUILDING CODE — RESIDENTIAL, 6TH EDITION (2017)
Comment: PLEASE SHOW COMPLIANCE WITH R302.9.2 SMOKE -DEVELOPED INDEX. FLORIDA BUILDING CODE —
10/24/
1018
RESIDENTIAL, 6TH EDITION (2017)
10/241
018
Comment: PLEASE SHOW COMPLIANCE WITH R302.10 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR
INSULATION. FLORIDA BUILDING CODE — RESIDENTIAL, 6TH EDITION (2017)
Comment: PLEASE SHOW COMPLIANCE WITH R302.11 FIREBLOCKING. 1, 1.1, 3,4 FLORIDA BUILDING CODE —
10/24/
018
RESIDENTIAL, 6TH EDITION (2017)
10/24/
018
Comment: PLEASE SHOW COMPLIANCE WITH R302.11.1 FIREBLOCKING MATERIALS — FLORIDA BUILDING CODE —
RESIDENTIAL, 6TH EDITION (2017)
10/241
018
Comment: PLEASE SHOW DIMENSIONS BATHROOMS COMPLING WITH R307.1 SPACE REQUIRED. SHOW FLORIDA
BUILDING CODE — RESIDENTIAL, 6TH EDITION (2017)
Comment: PLEASE SHOW COMPLIANCE WITH R309.4 AUTOMATIC GARAGE DOOR OPENERS. AUTOMATIC GARAGE
10/24/
018
DOOR OPENERS, IF PROVIDED, SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 325. FLORIDA
BUILDING CODE — RESIDENTIAL, 6TH EDITION (2017)
Comment: PLEASE INDICATE R310.2.2 WINDOW SILL HEIGHT. WHERE A WINDOW IS PROVIDED AS THE EMERGENCY
10/24/
018
ESCAPE AND RESCUE OPENING, IT SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES (1118 MM)
ABOVE THE FLOOR FLORIDA BUILDING CODE — RESIDENTIAL, 6TH EDITION (2017)
10/24/'
018
Comment: WINDOW J MASTER BEDROOM DOES NOT COMPLY WITH R310.2.1 MINIMUM OPENING AREA. FLORIDA
BUILDING CODE — RESIDENTIAL, 6TH EDITION (2017)
10/24/
018
Comment: PLEAE PROVIDE COMPLETE DETAIL FOR THE STAIRS. FLORIDA BUILDING CODE — RESIDENTIAL, 6TH
EDITION (2017)
10/24/
018
Comment: PLEAE PROVIDE COMPLETE DETAIL FOR THE STAIRS. FLORIDA BUILDING CODE — RESIDENTIAL, 6TH
EDITION (2017)
10/24/
018
Comment: PLEASE SHOW COMPLIANCE WITH R311.5.1 ATTACHMENT R311.7 STAIRWAYS R311.7.1 WIDTH. R311.7.2
HEADROOM R311.7.6 R311.7.8 HANDRAILS. R311.7.8.1 HEIGHT. R311.7.8.2 CONTINUITY.
10/245
018
Comment: PLEASE SHOW COMPLIANCE WITH SECTION R314 SMOKE ALARMS R314.3 LOCATION. 42.OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. HALLWAY TO BEDROOMS
Comment: PLEASE SHOW COMPLETE COMPLIANCE WITH R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA.
10/24/
018
TABLE R301.2 (1)PROVIDE ALL APICAL INFORMATION
97
aie- iar� -
ig & Development Services
8 Code.Regulation Division
300 Virginia Avenue
)rt Pierce, FL. 349,82
>)462-2172 Faxa(772)462-6443
Page 3
10/241 018 Comment:
10/24/ 018 Comment:
10/24/2018 Comment:
10/24! 018 Comment:
10/24 Li 8 Comment:
101241 018
10/241 018
10124/ 018
ZONING R VIE'
018
�18
318
318
18
REVIEW COMMENTS
PLEASE SHOW COMPLETE COMPLIANCE WITH FILL SECTION R403 OR IN ACCORDANCE WITH ACI 332.
PLEASE SHOW COMPLETE COMPLIANCE WITH SECTION R506 CONCRETE FLOORS (ON GROUND)
R506.2.1 FILL.
PLEASE SHOW COMPLIANCE WITH WITH R403.1.7 FOOTINGS ON OR ADJACENT TO SLOPES.
PLEASE SHOW COMPLIANCE WITH R506.2.4.2 R506.2.4.2 CONTRACTION JOINTS. # 2. CONCRETE SLABS
ON GROUND CONTAINING 6 x 6 WELDED WIRE REINFORCEMENT FABRIC
PLEASE IDENIFY MATERIALS TO BE USED - SECTION R702 INTERIOR COVERING R702.4.2 BACKER
BOARDS.
Comment:
PLEASE SHOW COMPLIANCE WITH R703.4 FLASHING. # 1 PLEASE IDENIFY MATERIALS TO BE USED
Comment: PLEASE INDICATE R802.7.2 ENGINEERED WOOD PRODUCTS.
Comment: PLEASE SHOW COMPLIANCE WITH R903.2 FLASHING R903.2.1 LOCATIONS. PLEASE IDENIFY MATERIALS
TO BE USED
INCOMPLETE Lydia Galbraith 8/2712018
Comment: THE SURVEY IS INCOMPLETE. PLEASE INDICATE:
- THE ROAD AND ELEVATION OF THE CROWN OF THE ROAD (11 MILE RD)
- PROPOSED FINISHED FLOOR ELEVATION. MIN. ELEVATION IS REQUIRED TO BE 181, ABOVE CENTER LINE
OF THE ROAD.
- INDICATE THE TYPE OF SURFACE OF THE DRIVEWAY IN FRONT OF THE GARAGE. THEY ARE REQUIRED
TO PROVIDE 2 PAVED PARKING SPACES OF EACH 10'X18'. THE PARKING SPACES MAYBE ON THE
DRIVEWAY. PLEASE INDICATE ON THE SURVEY.
Comment: THE PROPOSED SFR ON THE SURVEY IS NOT MATCHING WITH THE FLOOR PLAN. PLEASE INDICATE THE
COVERED ENTRY PORCH,STEPS AND THE BAYWINDOWS ON THE SURVEY.STEPS NEED TO MEET
SETBACKS AS WELL.
Comment: PLEASE PROVIDE A COPY OF THE WELL PERMIT.
Comment: PLEASE PROVIDE 2 FLOOR PLANS AND 2 SURVEYS STAMPED FOR APPROVAL BY THE HEALTH DEP.
Comment: BASED ON SLC AERIALS AND PROPERTY APPR. RECORDS THERE ARE STRUCTURES ON THE PROPERTY.
HOWEVER, THE SURVEY DOESN'T INDICATE THE STRUCTURES. ARE THEY STILL THERE? IF SO WHAT
TYPE OF STRUCTURES? ARE THE STRUCTURES GOING TO BE ON THE PARCEL 1 AFTER THE NEW LOT
SPLIT?