Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGESoil Nuclear Gauge _Associates, Inc. Report Date: 12/14/2018 Test Method: ASTM D 6938 Port St. Lucie Branch Florida CA No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 *QNNE-0 BY Client: Kerns Construction 2701 Industrial Avenue 2 Fort Pierce, FL 34946 � alp .l 68 - �G37 Project: 113-18-64-5482 3803 11 Mile Road 3803 11 Mile Road Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min Comp. M Remark 1 11/8/18 18-203 A -- 11.5 110.5 9.9 108.6 12 98 95 Pass 2 11/8/18 18-203 A -- 11.5 110.5 7.7 109.1 12 99 95 Pass 3 11/8/18 18-203 A -- 11.5 110.5 10.0 108.5 12 98 95 Pass 4 11/8/18 18-203 A - 11.5 110.5 11.7 108.3 12 98 95 Pass 5 11/8/18 18-203 A -- 11.5 110.5 12.6 108.0 12 98 95 Pass 6 11/9/18 18-203 A -- 11.5 110.5 8.5 106.7 12 97 95 Pass 7 11/9/18 18-203 A - 11.5 110.5 9.1 105.8 12 96 95 Pass 8 11/9/18 18-203 1 A - 11.5 1 110.5 1 8.7 1 1 77.8 1 12 98 95 Pass e 'hest Information , Test# ITest Location 1 Building Pad Fill: Permit Number 1808-0637. Southeast Corner of Pad. 2 Building Pad Fill: Permit Number 1808-0637. Northeast Corner of Pad. 3 Building Pad Fill: Permit Number 1808-0637. Northwest Corner of Pad. 4 Building Pad Fill: Permit Number 1808-0637. Southwest Corner of Pad. 5 Building Pad Fill: Permit Number 1808-0637. Center of Pad. 6 Building Pad Fill: Permit Number 1808-0637. Final Lift of Building Pad. NW Corner of Pad 7 Building Pad Fill: Permit Number 1808-0637. Final Lift of Building Pad. SW Corner of Pad 8 Building Pad Fill: Permit Number 1808-0637. Final Lift of Building Pad. SE Corner of Pad Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician -1.0 Top of Fill Troxler / T-3430 / 21330 / Tech, Port St. Lucie -1.0 Top of Fill Troxler / T-3430 / 21330 / Tech, Port St. Lucie -1.0 Top of Fill Troxler / T-3430 / 21330 / Tech, Port St. Lucie -1.0 Top of Fill Troxier / T-3430 / 21330 / Tech, Port St. Lucie Top of Fill Troxler / T-3430 / 21330 / Tech, Port St. Lucie -1.0 Top of Pad CPN / MC-3 / M330907151 / Tech, Port St. Lucie -1.0 Top of Pad CPN / MC-3 / M330907151 / Tech, Port St. Lucie -1.0 Top of Pad CPN / MC-3 / M330907151 / Tech, Port St. Lucie Remarks Comments ` Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth.is noted as "Backscatter". Gauge calibration data on file with the testing agency. RECEIVED MAR 1 R ?PIQ Permitting Department St. Lucie,Counr. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED :r PENDING OUR WRITTEN APPROVAL. Soil Nuclear Gauge Associates, Ind. Report Date: 12/14/2018 Test Method: ASTM D 6938 Port St. Lucie Branch Florida CA No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 Client: Kerns Construction 2701 Industrial Avenue 2 Fort Pierce, FL 34946 Tesf, Results - Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture M) In Place Dry Density (pcf) 9 11/9/18 18-203 A -- 11.5 110.5 8.9 106.2 Tesst Information Test # Test Location Elevation Reference 9 Building Pad Fill: Permit Number 1808-0637. Final Lift of Building Pad. NE Corner of Pad -1.0 Top of Pad Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauae calibration data on file with the testina aaencv. a Project: 113-18-64-5482 3803 11 Mile Road 3803 11 Mile Road Fort Pierce, FL Probe Depth (in) 12 1 96 1 95 Gauge Make / Model / SN ! Calibrated Percent I Min Comp. Compaction M CPN / MC-3 / M330907151 / Remark Pass Field Technician Tech, Port St. Lucie This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Dec 17, 2018 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic_copies -- AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.