Loading...
HomeMy WebLinkAbout24030475 DENSITY OF SOIL IN PLACE{ A. M. ENGINEERING AND Ift"G, INC. 3504 INDUSTRIAL 33RD STREET FT. PIERCE, FLORIDA 34946 LOCALOFFICE: (772) 461-7508 FAX: (772) 461-8880 { DENSITY OF SOIL IN PLACE Client: III James and Brenda Burnsed Report Date: 3/17/2003 Contrae'or: Client Technician: RA Site: 170 Boyd Road, Carboy Industrial Park Stem -wall Backfill Permit No.: 22090688 Test No. I ate sted Location Eleva- tion (ft) Field Test Results Proctor Max Dry Density (cf) Co m action Pass/ Fail HCP H2O % Dry Density (cf) Probe Depth In Place M Min Req'd M 9599 3,�17/03 Map Location 1 0-1 90+ 118.2 95+ 95 P 9600 1-2 90+1 118.2 95+ 95 P 9601 "" 2-3 90+ 118.2 - 95+ 95 P 9602 11" 3-4 90+ 118.2 95+ 95 P 9603 lilt 4-5 90+ 118.2 95+ 95 P 9604 I lilt 5-6 50 9.4 1 115.5 12 118.2 97.7 95 P 9605 Map Location 2 0-1 90+ 118.2 95+ 95 P 9606 lilt 1-2 90+ 118.2 95+ 95 P 9607 2-3 90+ 118.2 95+ 1 95 P 9608 lilt 3-4 90+ 1 118.2 95+ 95 P 9609 I lilt 4 - 5 90+ 1.18.2 95+ 95 P 9610 "" 5-6 50 8.6 114.6 12 118.2 97.0 95 P 9611 Map Location 3 0-1 90+ 1 118.2 95+ 95 P 9612 lilt 1-2 90+ 118.2 95+ 1 95 P 9613 2-3 90+ 118.2 95+ 95 P 9614 lilt 3-4 90+ 118.2 95+ 95 P 9615 lilt 4-5 90+ 118.2 95+ 95 P 9616 I lilt 5-6 50 8.9 115.1 12 118.2 97.4 95 P 9617 i Map Location 4 0-1 90+ 118.2 95+ 1 95 P 9618 lilt 1-2 90+ 118.2 95+ 95 P 9619 lilt 2-3 90+ 118.2 95+ • 95 P 9620 3-4 90+ 118.2 95+ 95 P 9621 I�I�' lilt 4-5 90+ 118.2 95+ 95 P 9622 lilt 5-6 40 7.4 113.4 12 118.2 95.9 95 P JRemarks: -All alelations are above stripped. surface. • The fieldensity tests were performed in general compliance with ASTM D 2922, Density of Soil in Place by Nuclear Methods. The Hal I Cone Penetrometer.(HCP) test, in conjunction with information about the soil type, is empirically correlated to the relative ensity of the subsurface soils. ! The labo atory Proctor maximum dry density accordance with_ASTM D 1551.' ' Distribution: I. , eviewed by:r - �I CLEO Client -' A. M: ENGINEERING AND TESTING, INC. SLC Bl Dept. - 1 R E 712�4- 2 30]'I Rebecca Grant-Ascoli, P. E. St, Lucie County Public Works Florida Registration No. 51863' i Burnsed(9599-' 22)170 Boyd Road.xls i I! A. M. LONNEERING AND TEAWINC. W04 INDUSTRIAL Vw STREET FORT PIERCE, FioltIDA 34946 (772) 461-7508 OFFICE - (772) 461-8880 FAX i 0Z