Loading...
HomeMy WebLinkAboutGAS TANK PLANSm y m m -' 7,nDIVERSIFIED SERVICES zn mac O C n DIVERSIFIED LEADER IN THE GAS INDUSTRY -0W m m cam g0 M 3 o cL Project Name: o®0 _+ c Z Varga z c CO 12351 Cessna Terrace WoS PSL, FL a— m � m n Date Drawn: 500 gallon LP tank n ~ < 08/08/18 below ground m z rt' z m Revision Dates 25' of 3/4" PE lopsi I-M-4 generator r800- TABLES: 396000 402.4 (25) 402.4 (28) 402.4 (32) NFPA58 16.1(n) 2nd stage reg 0 *LP Gas *11"wc del pres based on a 10 psi system *BTU ext=396000 *BTU int=0 *longest int run=NA *longest ext run=25' *shut off valves installed within 6' of each appliance *make up air by others if required THIS VESSEL IS DESIGNED FOR THE STORAGE �F— TT- QUEFfED-P-ETF�-OLEUM-GAS-ONL1' TOP VIEW 14 GA. COLLAR SLOTTTED HOLE W/ 2 1/2' X 3 1/2° SLOT CENTERED OVER OFFSIDE RELIEF VALVE HASP INGE HASP, a•IINr._rq 9 Or= U-U-I I -UM HIV T UNSPECIFIED WELD DETAILS 14GAF&DHEAD 16 O.D.- WITH 1" SF— I II II I R.S. c7'' I I I-ffLOAT GAUGE I I II I II I 3/16 3l16 V TMP' ________l1______ __ 3116 G, 'Optional)/ I - TYp 3/1fi L.S. 1 J 1114 0 11K SIDE ELEVATION 3/4 DIAM.' HOLES (4) PLACES NOTE; TANK MUST BE INSTALLED LEVEL, WITH ALL LEGS IN SAME PLANE TO ASSURE EVEN DISTRIBUTION OF LOAD AND OPTIMIZE a SLOT FITTING LAYOUT LCEIVED ® 2018 ounty, Pormj4ing OPTIONAL -- DOME BRACKET FOR UG GREEN ONLY —� ALONG. WELD SEAM May vary long seam END VIEW loc. to miss leg weld CERTIFIED BY; QUALITY STEEL CORPORATION CLEVEUWO, MS-FREMONT. OH- WEST JORDAN, LIT MAXALLOW.WORKPREss. 250 PSI AT 400 -F. SME M.O.M.T. -20 -F. AT 250 PSI E YEARBUILT w. U RT4 SE NO. LENGTH Ll20 IN. OUTSIDE OLkF_3_7_._51 IN HEAD THK, IN. SHELL THK IN. GRONDTYPERE IQ5 SURFACEAREA 100 SO. FT. CONTAINER ASSEMBLY HEADD.R. HEM. FOR LP GAS WATER CAPACHY 500 GALLONS THIS CONTAINER SHALL NOT CONTAIN A PRODUCT HAVING A VAPOR PRESSURE IN EXCESS OF 215 PSI AT 100°F. DIP TUBE LENGTH -BU' FULL AT 40°F. D.T= I 1051N. DATA PLATE DETAIL GENERAL NOTES: 1. LIFTING LUGS DESINGED FOR TOTAL LIFTING WEIGHT OF 1500#. TOTAL EMPTY WEIGHT IS 950#. . ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED . COMPLETE TANK DRIED TO REMOVE ALL MOISTURE . ALL WEIGHTS AND CAPACITIES ARE APPROXIMATE . EXTERIOR OF TANK TO BE GRIT BLASTED . PAINT PER SHOP ORDER VACUUM PURGE TANK I9. DIMENSION ARE SUBJECT TO CHANGE WITHOUT NOTICE. (NON -PRESSURE RETAINING COMPONENTS ONLY) 1O.THREADS OF ALL FITTINGS TO BE COATED WITH COMPOUND SUITABLE FOR USE WITH LP GAS 11. FLOAT GAUGE TO BE INSTALLED WITH FLOAT ARM 45° OFF LONGITUDINAL CENTERLINE OF TANK. 100 250 2340 ACCURACY OF GAUGE DEVICE. PART NO: O 105002X FITTINGS COUPLINGS SA-105 MARK QTY. SIZE TYPE REGO SERVICE MARK QTY. DESCRIPTION DWG. NO. REV. BY: - DESCRIPTION DATE TANK FLANGES SA-105 or SA-181-70 A 1 1 XH FLG. 0U66U4GT RELIEF VALVE 1 1 SHELL- 0218' X 63' X 116 11116' - SA414G 14 CDH ADDED HINGE& HASP AT SHELL 12/12/D1 ADAPTOR SA-105 B 1 1 XH FLG. �uL007579T LOATGAUGE 2 2 HEADS-37-I.D.XO.165'-HEMI:SA414C t5 CDH ADDED NOTE AT LEG DESCRIPTION 316/02 C 1 1-1/4 XH FLG. FILLVALVE 3 2 LIFTING LUGS D- 63 16 CDH REVISED MDMT PRESSURE T0250 PSI 6I23102 500W.G.ABOVE/UNDERGROUND E 1 314 XH FLG. PT007556RSlO.5 MULTI VALVE 4 2 TANK LEGS 0-3 17 CDH CORRECTED RELIEF VLV. MODEL NOS. 11/5103 PROPANE TANK -TYPE IQ5 (FORMERLY AWT-9A) F 1 314 D0759OUT CHEK-LOK 5 1 DOME D-5 18 - AGUG STANDARD TOP VIEW WITH HINGE AND HASP FOR NON-UG GREEN TANKS I I I I OPTIONAL BOTTOM DRAIN I.D. I I I I I I I 40 I I BOTTOM VIEW MARK QTY. SIZE HOLE DIA NOTE: SEE TANK DRAWING FOR REVISION BLOCK A 1 1 113/16 B 1 1 113/16 c 1 1-1/4 z 1/1s E 1 3/4 19/16 F 1 3/4 SEE DETAIL G (OPT) 1 1 1/4 21116 TOP VIEW WITH DOME BRACKETS FOR UG GREEN TANKS 500 W.G.ABO\ PROPANE TANK -TYPE QUALITY STET FITTII 01f03/00 WRAC 4" - 1/2" PE tubing sleeve 1/8" steel cable 1/8" galy, cable cl AK4 steel auger anchor 4" grade - ade DIVERSIFIED SERVICES DIVERSIFIED LEADER IN THE GAS INDUSTRY Project Name: Undergorund LP Storage Typical anchoring standard Date Drawn: 05/14/18 Revision Dates Notes: When necessasry to prevent flotation, or when required, underground LP tanks shall be anchored using 4"-AK4 auger anchors and 1/8" steel cable. Cable shall be inserted in 1/2" PE tubing to protect the tank from direct contact with the cable. Locatee cable approximately 14" inward of the welded seam on. both ends.Use 4 1/8" galvanized cable clamps to secure to the anchor. 38-146 For SI Central AC compressor (source of ignition) 1 It = 0.3048 M. PETROLEUl&1 GAS CODE Window air conditioner (source of ignit Intake to direct - vent appliance= 10 It (min) o (Note 1) - 1VIo ft (min) � (Note 1) / 10 It (min) 10 ft (min) (Note 1) (Note 2) Crawl space opening, window, or exhaust fan 10 ft (min) / 2000 t (Note 2) / galWc. Nearest line of adjoining property that can be / built upon Notes: (1) The relief valve, filling connection, and fixed maximum liquid level gauge vent connection at the container must be at least 10 ft from any exterior (1) The � relief vale openings Into direct -vent appliances, or mechanical ventilation air intakes. Refer to 5.3.4.4. (2) No Part of an underground container can be less than 10 ft from an important building or line of adjoining property that can be built upon. Refer li 6.3.2.3. IGUBEI I.1(c) Underground ASME Containers. (Figure for illustrative purposes only, code compliance required.) This c but iv jurisd code. Cal, An of NI Chap condi sion; fees; i all of with; provil BE dirtio; SE ment file m (juris adop mex J Sample Ordinance Adopting NFPA 58 c is not a Bart of the requirements of this IWA document :ded for informational purposes only. following sample ordinance is provided to assist a n in the adoption of this code and is not part of this IANGE NO. finance of the fjurisdirtionl adopting the 2017 edition 58, Liquefied Petroleum Gas Code, documents listed in of that code; prescribing regulations governing s hazardous to In and property from fire or explo- viding for the issuance of permits and risdlecd on of and aling Ordinance No. of the (j ordinances and parts of ordinances in conflict there- viding a penalty; providing a sever -ability clause; and for publication; and providing an effective date. ORDAINED BY THE [govenaing body] OF THE Uurii- ION 1 That the Liquefied Petroleum Gas Code and docu- iopted by Chapter 2, three (3) copies of which are on are open to inspection by the public in the office of the ions keeper of records] of the &urisdictionl, are hereby and incorporated into this ordinance as fully as if set out at length herein, and from the date on which this ordi- nance shall take effect, the provisions thereof shall be control- ling within the limits of the owr.isdirtion]. The same are hereby adopted as the code of the fj-u7isdiction] for the purpose of prescribing regulations governing conditions hazardous to life and property from fire or explosion and providing for issuance of permits and collection of fees. SECTION -2 Any person who shall violate any provision of this code or standard hereby adopted or fail to comply there- with; or who shall violate or fail to comply with any order made thereunder; or who shall build in violation of any detailed state- ment of specifications or plans submitted and approved there- under; or failed to operate in accordance with any certificate or permit issued thereunder; and from which no appeal has been taken; or who shall fail to comply with such an order as affirmed or modified by or by a court,of competent jurisdic? tion, within the time Fixed herein, shall severally for each anti every such violation and noncompliance, respectively, be guilty of a misdemeanor, punishable by a fine of not less than $ nor more than or by imprisonment for not less than days nor more than days or by both such fine± and imprisonment. The imposition of one penalty for any viola- tion shall not excuse the violation or permit it to continue; afci all such persons shall be required to correct or remedy_iL4c 3 violations or defects within a reasonable time; and wheu'fib; otherwise specified the application of the above penalty sh. 2017 E