45--unlast Metal
Value Engineered Meta/ Roofing rM
Vtkf
RIt
.26 04.-'24" R001= P:ANE.L;.01!_ER 15132" PLYWO.O.D
FLORID U ACOPY
423.7
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBIUTY OF THE
Product Evaluation Report CONTRACTOR OR RECORD
26GA 5 V CRIMP Roof Ponel over 15/32" Plywood
Florida Product Approval #21423.7
Florida Building Code 2017 6th ed SCANNED
Per Rule 61G20-3 Method: 1-0 BY
�t. Category: Roofing Subcategory: Metal Roofing Compliance Method: �1,7de C®untv
Rule 61620-3
HVHZ
Product Manufacturer:
Sunlast Metal
2120 SW Poma Drive
Palm City, Florida 34990
Engineer Evaluator
Diane G. Marotta, P.E. FL reg # 82591
- 1915 NE 45"' ST. #107
Fort Lauderdale, FL 33308
9.54-776-8004 -
Validator:
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
,rh 1 d 8- 0 Z4
vr(►2k� (�X1L
LUCIE COUNTY BUILDING DIV ION
IEWED FOR CIANCEIEWJD —r'
g'AND`Pl5RMt7`'(9UST BE KE )Og
OR NO INSPECTIONS) W L MADE
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Diane G- Marotta, P.E.
FL reg # 82591
seal
ipliance Statement: The product as described in this report has demonstrated compliance with the
orida Building Code 2017, Sections 1504.3.2, 1507.1.1,1507.4.3,1518.9, 1523.6.5.2.4
duct Description: 26GA 5 V Crimp Metal Panel, 24" Width, Roof panels, 5/8" Rib height, 12" O.C.
el THRU FASTENED into 15/32" APA Plywood decking. Non-structural Application.
R USE IN HVHZ.
26GA metal conforming to Florida Building Code 2017 Section 1507.4.3 Yield Strength: 55KSI
Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3
Dimensions: Panel Width: 24" width
aver: Wood-Zac XG fastener w/Neoprene washer or equivalent #10 Hex Head. Corrosion Resistant per Florida Building
2017 Section 1506.7
6" minimum penetration through plywood
)sion Resistance: Per Florida Building Code 2017, Section 1506.6,1507.4.4
2" APA plywood, plywood supports at maximum 24' O.C. Design of plywood and plywood supports are outside the scope
is evaluation. Must be designed in accordance w/ Florida Building Code 2017.
Uplift Pressures: Uplift Design Pressure: with Safety Factor of 2
T
BLE A
R
of Areas Field Perimeter/Corner
ax Design Pressure-78.5psf-189.25psf
F
Istener Spacing 16" o.c. 8" o.c.
F
stener Size #10 # 10
Optional.Rigid Insulation board, 3" max thickness compliant with FBC 2017 section 1508.2
Assurance: In accordance with FBC 2011 and Rule # 61620-3: Keystone Certification,
QUA 1824
References:
hitectural Testing Inc (TST 1527) # F0755.01-450-18 TAS 125-2003
hitectural Testing Inc (TST 1527) #0412-1017-05 TAS 125-2003
hitectural Testing Inc. (TST 1527)# SFMS-001-02-01 TAS 100-1995 , B8944.01-450-18 TAS 125
Construction Material Tech nologies(TST5878) AKZC-001-02-01/05 TAS 110-2000
RI Construction Material Tech nolog ies(TST5878)AKZC-001-02-01/05 ASTM B 117-2002
KZO Nobel Coatings, Inc. Lab Form ASTM G 153
Compliance: The product described herein demonstrated compliance with The Florida Building Code (FBC) 2017 Section
3.2. The product evaluation is limited to compliance with the structural wind load requirements of the FBC 2017, as
to Rule 61G20-3.
imum Slope Range 2/12 Minimum Slope per Florida Building Code 2017, and in accordance with Manufacturers
mmendations.
31lation: Install per manufacturer's recommended details in compliance with FBC 2017 and RAS 133.
erlayment: Per Manufacturer's installation guidelines per Florida Building Code 2017 Chapter 1507, Chart 1507.1.1
Page 2 of 4
Ro4 Panel Fire Classification: No classification.
Sheor Diaphragm: values are outside the scope of this report.
Des gn Procedure: Based on the dimensions of the structure, applicable wind loads are determined using Chapter 16 of the
Flor IdIa Building Code 2017 -roof cladding wind loads. Component wind loads for roof cladding are compared to the allowable
pre!$ure listed above. Design professional shall select the applicable erection details to reference in drawings for correct
fast ner attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be
co liant with Florida Building Code 2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
Req fired wind loads shall be determined per project per FBC 2017 and any rational analysis computation shall be prepared by a
licet sed design professional.
Cer ificate of Independence: Diane G. Marotta, P.E. does not have nor will acquire financial interest in any company
ma ufacturing or distributing products under this evaluation. Diane G. Marotta, P.E. is not owned or operated or controlled by
any company manufacturing or distributing product under this report.
PRODUCT EVALUATION REPORT
Page 3 of 4
C.,unlast
Metal
Value Engineered Meta/ Roofina rM
KEY IOVEST :SERIES V RIM
INSTALL DETAILS
Fastener: # 10 HexHead w/neoprene washer per Evaluation Report Specification
TYPICAL ASSEMBLY PROFILE VIEW
vvenap
Page 4 of 4
Florida Building Code Online--
BCIS Home I log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts i Publications I FBC Staff Io BCIS Site Map I Links I Search'
C
'' Product Approval
re USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail d `AN NED
BY
FL # FL16027-112 ��. Z��9� (�®���
Application Type Revision `�
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Tri-Built Materials Group, LLC
Address/Phone/Email PO Box 70
Rutherford, NJ 07070
(800) 516-'1485
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.ruizOtribuiltmg.com/
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East, Rutherford, NJ 07073
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
Quality Assurance. Representative
Address/Phone/Email
Category
Subcategory
C Richard Schurman
9050 Louisiana Street
Merrillville, IN 46410
rich.schurman@alliedbuiiding.com
Roofing
Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
10/06/2018
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received .
Certificate of Independence
FL16027 R2_C0l_2017_01__Nieminen.pdf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
FM 4470
2012
FM 4474
2011
Equivalence of Product Standards
1/2
I
j https:L
i
Florida Building Code Online
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
09/25/2017
Date Validated
09/30/2017
Date Pending FBC Approval
10/08/2017
Date Approved
12/12/2017
Summary of Products
FL #
Model, Number or Name..
Description
16027.1
TRI-BUILT Modified Bitumen. Roof
SBS and APP modified bitumen roof systems
Systems'
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16027 R2_II_2017 09_FINAL Al ER TRI-
Approved for use outside HVHZ: Yes
BUILT_MODBIT FL16027-R2.pdf
Impact Resistant: N/A -
Verified By: Robert Nleminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The Design Pressure noted in this application
Evaluation Reports
refers to one system. Refer to ER Appendix for all systems and
FL16027 R2_QE_ZQ127_09 FINAL EB_TR
max. design pressures. 2.) Refer to ER Section 5 for Limits of
BUILT_MODBIT FL16027-R2.pdf
Use.
Created by Independent Third party: Yes
Ek ide;ct
Contact Us :: 2601 Blair Stone Road. Tatlahm= FL 32399 phone: 850-481- 824
The State of Florida Is an AA/EEO employer. Qpy(Lght 2007-2013 State of Florida, : Priyaa Statement :: Accessibility Statement ,:Refund statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However emaif addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please dick UM.
Product Approval Accepts:
Credit Card
. Safe.
a
212
TRINITY I ERD
IAPF'EnDIX3:;ATTACHMENT.
REQUIREMENTSFpRi11lINDUPtIFi;SE515TANCE i' "•
.:•;
.' ..' -
Table
Deck
Application
Type
Description
page
1A-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
IA-2
Wood
New; Reroof (Tear -Off) or Recover
A-2 '
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New, Reroof (Tear -off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation; Bonded Roof Cover
5
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
ID
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
6
3E-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
7
1E-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
g
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
g
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9 .
2B
Steel or Structural concrete
New, Reroof (Tear -Off) -or Recover
C
Mech. Attached. Insulation, Bonded Roof Cover
9
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
10
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
11-14
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
14
4A
LWIC
New or Reroof (Tear -Off)
A-1
Sonded.fnsulation, Bonded Roof Cover
15-16
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded insulation, Bonded Roof Cover
16
4C
LWIC
New or Reroof (Tear -Off)
E
Non -insulated, Mech. Attached Base Sheet, Bonded Roof Cover
1749
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
20
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
21
Sc
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
22
SE
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
22
6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 23
6B Gypsum New, Reroof (Tear -Of" or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 24
6C Gypsum New, Rerbof (Tear -Off) or Recover C Mech. Attached insulation, Bonded Roof Cover 24
6D Gypsum New, Reroof (Tear -off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 24
7A Various Recover 'A-1 Bonded insulation, Bonded Roof Cover 25-26
75 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover -26
The following notes apply to the systems outlined herein -
I. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement- �r
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published Installation instructions.
3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements of F.A.C. Rule 63G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover.
Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-112 for FL16027-R2
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2027
Prepared by: Robert Nfemfnen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1495 Appendix 1, Page i of 26
TRINITY 3 ERD
Minimum 200 psi, minimum 2-inch thick lightweight Insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5. Preliminary Insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ HA (HA):
Full coverage at 25-30 Ibs/square.
➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS):
Continuous 0.75 to 1-Inch wide ribbons,12-Inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA):
Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c.
➢ OMG 01yBond 500 (06500):
Continuous 0.75 to 1-inch wide ribbons, 22-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green maybe used where 01yBond 500 Is referenced.
➢ 01yBond Classic (OB Classic):
Full coverage at 1 gal/square.
➢ ICP Adhesive & Sealants CR-20:
Continuous 2.5-3.5-Inch wide ribbons,l2-inch o.c.
➢ Note. When multiple layers(s) of insulation and/orcoverboard are Installed In ribbon -applied adhesive, adhesive ribbons shall be staggered from layer-to-loyer a distance of one-half the ribbon spacing.
Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MOP listings in the tables; rather if MOP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below maybe used as a drop -In for the
equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA):
MOP -157.5 psf (Min. 0.5-inch thick)
➢ OMG 01yBond 500 (OB500):
MOP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond SOD (08500);
MOP -187.5 psf (Min. 0.5-Inch thick ISO 95+ GL)
➢ OMG 01yBond 500 (OB500):
MOP -315.0 psf (Min.0.5-inch thick ENRGY 3)
➢ OMG 01yBond SOD (011500):
MOP -487.5 psf (Min. 0.5-Inch thick ACFoam 11)
➢ ICP Adhesive & Sealants CR-20:
MOP -117.5 psf (Min.1.0-inch thick)
B. Bonded polyisocyanurate insulation boards shall be maximum 4 x4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone I design pressure determined in accordance with FBC
Chapter 10, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDi, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the IlmitationS set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet I-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast In accordance with TBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC Is not referenced, the minimum design mix shall be 300 psi. in all cases, the minimum top -coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-112 for FL16027-R2
Certificate of Authorization #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 2 of 26
TRINI?Y 1 ERD
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
Reference
Layer
Material
Application
BP -AA
(Base and Ply sheets, Asphalt -Applied)
Base Ply
FBC Approved ASTM D4601, Type II
HA at 20-40 Ibs/square
Ply
FBC Approved ASTM D2178, Type IV or VI
SBS-AA
(SBS, Asphalt -Applied)
Cap Ply -
TrlBulit SBS Granular
HA at 20-40 Ibs/square
SBS-TA
(SBS, Torch -Applied)
Cap Ply
TriBuilt SBS Granular
Torch -Applied
SBS-SA
(SBS, Self -Adhering)
Base Ply
TriBUllt SA SBS Base
Self -Adhering
Cap Ply
TriBuilt SA SBS Cap
APP-TA
(APP, Torch -Applied)
Base Ply or Ply
TriBuilt APP Smooth
Torch Applied
Cap Ply
TriBuilt APP Smooth, TriBuilt APP Granular
APP-SA
(APP, Self -Adhering)
Cap PI y
TrlBuilt SA APP Ca p -
Self -Adhering
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MOP listings below vs. those in Table 3A
applies:
VAPDR:BARRIER OPnoNs; STRUCi',UaAL Cb,NCRETE DECK, ADHERED INSULATION PER TABLE 3A „ +' •:-.` •' ` •;
Option #
Primer
Vapor Barrier
Insulation Adhesive
MDP (psf)
Type
Attach
VB-1.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Inta-Stik or CR-20,12-inch o.c.
-60.0
VB-2.
ASTM D41
TrlBullt SA SBS Cap
Self -Adhering _
Insta-Stik,12-inch o.c.
-75.0
VB-3.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Millennium One Step Foamable Adhesive,12-inch o.c.
-157.5
VB-4..
ASTM D41
TrlBullt SA SBS Cap
Self -Adhering
CR-20,12-inch o.c.
-270.0
VB-5.
ASTM D41
TdBullt SA SBS Base
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20,12-inch o.c.
-290.0
17. -Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL16027-R2
Certificate of Authorization #9503 eH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1495 Appendix 1, Page 3 of 26
TRINITY a ERD
. t :.TABLE 1E 2 ,WOOD DECKS NEW CpNSiR11CTfON,,REROOF (TeaR-OFF)'oR Ri:coveR
„SYSTEM;TYPE, E ;NON INSULATED,_MECHANICALLY;ATTAGHED BASE SHEET,:BONDED,ROOF COVER
System
Deck (Note 1)
Base Sheet
Roof Cover (Note 15)
MDP
Base
fastener:
Attach
Base Ply
Cap Ply
No.
(Psf)
Min.19/32-Inch
Polygiass Elastobase, Polyglass Elastobase
Poly, Polygiass G2 Base, CertainTeed
OMG Flat Bottom Plates (square) with
12-Inch o.c in 4-Inch lap and 12-Inch
(Optional) One or
5B5-AA, 585-
W-1
plywood at max.
Glasbase, Firestone MB Base, JM Perma-
Roofgrip #14, Dekfast Hex with Dekiast #14
o.c. in two, equally spaced, staggered
more BP -AA or
TA, APP-TA
-52.5
24inch spans
Ply 28, Tamko Glass Base or GAFGIAS #75
or TruFast MP-3 with TruFast HD
center rows
APP-TA
W-2
Min.19/32-Inch
plywood at max.
Polyglass Elastobase or Polyglass
Dekfast Hex with Dekfast #14 or TruFast MP-
12-Inch o.c. in 4-Inch lap and 12-Inch
One or more SBS-
SBS-SA, APP-
Elastobase Poly with poly top surface
3 with TruFast HD
o.c. in two, equally spaced, staggered
: SA
SA, SBS TA or
-52.5*
24-inch spans
center rows
APP-TA
W-3
Min.19/32-inch
at
Polygiass Elastobase or
OMG Flat Bottom Plates (square) with
12-Inch o.c. in 4-inch lap and 12-inch
(Optional) One or
SBS-AA, SBS-.
plywood max.
Elastobase PolyPolygiass
Roofgrip #12
o.c. In two, equally spaced, staggered
more BP -AA or
TA, APP-TA
-60.0
24-inch spans
center rows
APP-TA
W-4
Min.19/32-Inch
at max.
Polygiass Elastobase or Polygiass
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-Inch lap and 12-inch
in
One or more SBS-
SBS-SA, APP-
plywood
Elastobase Poly with poly top surface
Roofgrip #12
o.c. two, equally spaced, staggered
SA
SA, SBS-TA or
-60.0*
24-inch spans
center rows
APP TA .
Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-112 for FL16027-R2
Certificate.of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (8W) 516-1485 Appendix 1, Page 8 of 26