Loading...
HomeMy WebLinkAboutPLAN EXAMINER REVIEW FORMContractor Mechanical Building PIE HHo�ome��Adddr�r lieil�d;.IZ�L' Form RIPER 1.01 8Mar 10 County, Town, Municipality, Jurisdiction Header Information Florida Breeze ��10 REQUIRED ATTACHMENTS' ATTACHED t Manual J1 Form (and supporting worksheets): Yes Q No ❑ tense # CAC1814113 �QO� ��L1� or MARE Form' (and supporting worksheets): Yes ❑ No X1 OEM performance data (heating, cooling, blower): Yes QX No [I# Manual D Friction Rate Worksheet: Yes ❑ No ❑X Duct distribution system sketch: Yes No N ,s (Street or Lot#, Block, Subdivision) Winter (Design Conditions Outdaor temperature 42 OF Indoo temperature 70 OF Total eat loss 37018 Btu/h. Summ r Design Conditions Outd or temperature 95 OF Indoo temperature 75 OF Grains difference 53 p Gr @ 50 % Rh Sens I le heat gain 35726 Btu/h Late heat gain 7313 Btu/h Total heat gain 43039 Btu/h Equipmenl type Heat pump Furnace lHeat pump, Boiler, etc. Model R4H448(A,G)KC* Heating Lut capacity 45000 Btu/h Heat pur Ips - capacity at winter design outdoor conditions Auxiliary +heat output Capacity. Btu/h Building Construction Information Building Orientation (Front door faces) South North, East, West, South, Northeast, Northwest, Southeast; Southwest Number of bedrooms 5 Conditioned floor area 2605 Sq Ft ' Number of occupants . 6 Windows Roof Eave overhang depth' '� . Ft Internal shade Eave Blinds, drapes, etc Depth Window Number of skylights 0 Coolina EauiDment Data Equipment type Heat pump Air Conditioner, Heat pump, etc Model R4H448(A,G)KC` Sensible cooling capacity 39143 Btu/h Latent cooling capacity 8190 Btu/h Total cooling capacity 4733.3 Btu/h Design airfl w CFM Longest supply duct: External St tic Pressure (ESP) IWC Longest return duct: Componen I'Pressure Losses (CPL) IWC Total Effective Length (TEL) Available Italic Pressure (ASP) IWC Friction Rate: ASP = ESP - CPL Friction Rate = (ASP x 100) * TEL Printed Name Krist�rl Kelly Signature Blower Data Heating CFM 1839 CFM Cooling CFM 1839 CFM Ft Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, Ft Lined sheet metal, Other (specify) Ft Branch Duct: Duct board, Flex, Sheet metal, IWC Lined sheet metal, Other (specify) Date 1 /14/2019 ' The AHJ sh II have the discretion to accept Required Attachments printed from approved ACCA software vendors, see ast on page z or instructions. ' If abridged V,6rsion of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13`of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Softwsre Rhvac program. IAir Conditioning Contractors of America Manuel S (Residential Equipment Selection) Prolea Information Name: City: f -_ 7 Altitude: Altitude Adjustment: 1.00 if J..Load Calculations I toad Sensible Latent SHR ,0335726 7313 0.830 %000nny Lmign rnrormatron Outdoor Design Temp: 91 OF db Outdoor Design Temp:® OF db Indoor Design Temp: 75 OF db Heat Loss 1.. 1�ACCK Summer Winter ®%RH OF wb Airflow Calculations Design TD for Airflow 19 Design Sensible CFM 1709 Man l cturer: 1COMFORTMAKER. Fumaos Model #: AFUE:�, Coil of Fan -Coil Model A FXM4X48"AL Condenser Model 8: R4H448 A,G KC• SEER: 14.5 HSPF: 8.50 (A) &J'anufacturer's Cooling Performance Data Lower Entering Coil Temperature = 75 (F db) CFM Rated CFM C Rated RA Temperature Rated CFM Q Design RA Temperature 1400 Rated CFM Q Rated RA Temperature Return Air (F wb) 65 83 ® Outdoor Temperature = Total BTUH Sensible BTUH 45,860 32,9W 44,384 35,566 42,470 39,430 ® (F db) Latent BTUH SHR f 2,67fl 0.7225 8,818 0.8013 3,040 0.9284 (8) i I nufaeturees Cooling Performance Data Higher Return Air Outdoor Temperature = ® (F db) Entering Coil Temperature - 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent STUH SHR Rated CFM @ Rated RA Temperature 65 52,150 37,450 14,700 0.7181 Rated CFM Q Design RA Temperature 1900 ® 49,150 39,930 9,220 0.8124 Rated CFM a Rated RA Temperature l� 4a,65o 43,650 1,000 0.9n6 Maniclurers Cooling Performance Data (interpolated) I Design Return Air Outdoor Temperature = 95 (F db) -CFM (F wb) Total BTUH Sensible STUH Latent BTUH SHR 38,266 9,087 0.8084 Excess Latent Capacity calculation + 877 877 Capacity ® Design CFM / RA (F wb) 1709.4 ® 47,3351 39,143 8,190 0.827 Equipment Capacity as a. % of Design 109.9896 109.5896 111.99% Heat Pump Date Man ! cturees Fumaoe Data Capacity 47 OF db 48,280 Capacity 17 'Fdb 26,080 Input Output Balance Point -23.8 Supplemental Heat Required -15.87 Desired Calculated