Loading...
HomeMy WebLinkAboutENVELOPE LEAKAGE TEST REPORTFORM Project Nar, Street: City, State, Design Loc Cond. Floo Envelt Regressi C: _ 7 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Express Hayden ST LUCIE LEFT R38 6FLEX 71NF ST LUCIE , FL, FL, ST_LUCIE_CO INTL 2601 sq.ft. Leakage Test Results Data: n: C;--io nrll'&Ar riff Onini Tact nnta R: Builder Name: Permit Office: Permit Number: Jurisdiction: Cond. Volume: 21691 cu ft. HOUSE PRESSURE I FLOW: E Pa cfm 2 Pa cfm 3 Pa cfm r 4 Pa cfm i 5 Pa cfm g Pa cfm Leakage Characteristics Required ACH(50) from FORM R405-2017 : Tested ACH(50) ` : *Tested leakage must be less than or equal to the required ACH(50) shown on Form R405-2017 for this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation system. R402.4.1: Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate nes 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals), Testing shall be conducted by either indiv i uals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved t11 rd party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be pei ormed at any time after creation of all penetrations of the building thermal envelope. Dunn testing: p y weatherstripping 1 Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstri m or other infiltration control measures; 2! Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3Interior doors, if installed at the time of the test, shall be open; 4 Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; Heating and cooling systems, if installed at the time of the test, shall be turned off; and Supply and return registers, if installed at the time of the test, shall be fully open. I hereby ertify that the above envelope leakage performa',l ce results demonstrate compliance with Flori a Energy Code requirements in accordan a with Section R402.4.1.2. SIGNATURE: PRINTED NAME: DATE: Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. BUILDING OFFICIAL: DATE: 01 fro ttitrt��`'�• E2"N�� . � so Q [ N. t9 >ui M 51111248 10:42 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1