Design Certification for Wind Load Compliance `` By
dfication is to be completed by the project design architect or engineer. This Certification must be subLUM- Unty
ins for building permits involving the construction of new residence (single or multi- family), residential addition, any
structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior
Ins (provided that no structural walls, columns or other similar component is being effected) and certain other minor building
For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172.
-
Pro ec Name A-0li
b� '�°flC►� IA
'
Street 4ddress
94-AAe„1z w "t
Permit Number
F-L
'Occupancy Type
Construction T e
it
Ce ' ;cation Statement:
—1 certi that, to the best of my knowledge and belief, these plans and specifications have been designed to
compl ' with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie
Coun ' -I also certify that structural elements depicted on these plans provide adequate res' ance to the wind
loads d d forces specified by current code provisions.
Desi Parameters and Assumptions Used: (Please check or compw. ppr to box.)
1. Flo 'da Building Code 2004 Edition Atft 7- 04,
Incl ,sive of 2006 and 2007 revisions.
2. Burl ' g Design is (check one) Enclosed \\OEnclosed ✓ Open Building
3. Burl ing Height: �- • ca' 4. Wind Speed Used in Building Design: V95 3 second gust
5. Winj Exposure Classification (refer to exposure tables in Building Code identified in Line #1):
6. Aver'I�ge Wind Velocity Pressure on Exterior Faces of Structure AS -*1 PSF
7. Peak ind Velocity Pressure on Exterior Faces of Structure 1'54-1 PSF
I
8. Impo', tanee/Use Factor (obtain from Building Code):
I
9. Load Floor 2SO PSF RooVdead 'ZO PSF Roof/live 7-® PSF
iZ pk Pr-..,
10. Wer Shear Walls Considered for Structure Yes No
check one): ( ) (if No, attach explanation]
11. Is a I ontinuous Load Path Provided (check one): Yes ✓ No (if No, attach explanation
12. Are omponent and Cladding Detail Provided (check one): Yes No ✓(if No, attach explanation)
13. Mini um Soil Bearing Pressure: PSF
As with 'used by my seal, I hereby certify that the information included with this certification is true and
correct, t,l the best of my knowledge and belief.
j Name: d01'0*VW1A44*7"' Certification_ #: �'� [Seal Here]
Design ,,Firm: /4} j/�"-� Date:, SLCCDV Form # 020-00