HomeMy WebLinkAboutNOA ROOF SYSTEM FOR CONCRETE DECKWANNE® BY MIAMIDADE JI DING CODE COMPLIANCE OFFICE (BCCO) tODUCT CONTROL DIVISION NOTICE OF ACCEPT GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MUNI I, FLORIDA 33130.1563 (305) 375-2901 FAX (305) 375-2908 This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). s NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for lity assurance purposes. If this product or material fails to perform'in the accepted manner, the manufacturer incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such iuct or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is ,mind by BCCO that this product or material fails to meet the requirements of the applicable building code. product is approved as described herein, and has been designed to comply with the High Velocity Hurricane e of the Florida Building Code. GAF Conventional Built -Up -Roof System for Concrete Decks. dEWAL of this NOA shall be considered after a renewal application has been filed and there has been no ge in the applicable building code negatively affecting the performance of this product. t IINATION of this NOA will occur after the expiration date or if there has been a revision or change in the rials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any act, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply any section of this NOA shall be cause for termination and removal of NOA. )VERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall done in its entirety. IFECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #00-0403.02 and consists of pages 1 through 28. The submitted documentation was reviewed by Frank Zuloaga, RRC. NOA No: 03-0430.14 19 Expiration Date: 11/06/08 Approval Date:10/31/03 Page 1 of 28 ROOFING SYSTEM APPROVAL CategM: Roofing Sub-C_ ategM: BUR Deck Tvne: Concrete Maximum Design Pressure -457.5 psf Fire Classification: See General Limitation #1 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Descriution GAF Asphalt Concrete 5, 55 gallons ASTM D 41 Asphalt concrete primer used to promote Primer (MatdxTM 307 adhesion of asphalt in built-up roofing. Primer) GAP Mineral Shield® 60 lb. & 100 lb ASTM D 1863 Granules for surfacing of exposed asphalt, Granules bags cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. GAF WeatherCoat® 5 gallons ASTM 1227 Surface coating for smooth surfaced roofs. Emulsion (MatrixTM Fibered 305 Emulsion) GAF Premium Fibered 1, 5 gallons ASTM D 2824 Fibered aluminum coating. Aluminum Roof Coating (MatrixTM System Pro Aluminum Roof Coating Fibered 301) GAF Jetblak All 1, 5 gallons ASTM D 3019 Refined asphalt blended with a mineral Weather Plastic ASTM D 3409 stabilizer and fibers. Permits adhesion to wet Cement (MatrixTm and dry surfaces. Standard Wet/Dry Roof Cement 204) GAF Aluminum 5 gallons Mineral colloidial bituminous emulsion with Emulsion reflective aluminum flakes. GAF Aluminum Roof 5 gallons ASTM D2824, Non-fbered. aluminum pigmented, asphalt Paint (MatrixTM Type I roof coating. System Pro Aluminum Roof Coating Fibered 302) GAF Built -Up 1001b. cartons, ASTM D312, Interply mopping and surfacing asphalt Roofing Asphalt bulk Tpyes I, II, III and IVi GAFGLASO #75 39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat Wide base sheet. NOA No: 03-0430.14 Expiration Date:.11/06/08 Approval Date:10/31/03 Page 2 of 28 Test Product Product Dimensions Specification Descriution GAFGLAS #80 39.37" (1 meter) ASTM D4601 Asphalt impregnated and coated, fiberglass U1tima7 Base Sheet Wide base sheet. GAFGLAS F1exP1yTM 39.37" (1 meter) ASTM D 2178 Type VI asphalt impregnated glass felt with 6 Wide asphalt coating. GAFGLAS Ply 40 39.37" (1 meter) ASTM D 2178 Type IV asphalt impregnated glass felt with Wide asphalt coating. GAFGLAS® Mineral 39.37" (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet Wide surfaced with mineral granules. GAFGLAS® 39.37" (1 meter) ASTM D3672 Fiberglass base sheet coated on both sides STRATAVENT® Wide ASTM D 4897 with asphalt. Surfaced on the bottom side Eliminator Perforated with mineral granules embedded in asphaltic coating with factory perforations: GAFGLAS® Flashing various Asphalt coated glass fiber mat flashing sheet available in three- sizes. GAFGLASO 39.37" (1 meter) ASTM D3672 Fiberglass base sheet coated on both sides STRATAVENT® Wide ASTM D 4897 with asphalt. Surfaced on the bottom side Eliminator Perforated with mineral granules embedded in asphaltic Nailable coating. RUBEROID MOP 39.37" (1 meter) ASTM D5147 Non -woven polyester mat coated with Smooth Wide ASTM D6298 polymer modified asphalt. Does not have a factory applied surfacing. RUBEROID 1 sq. roll ASTM D5147 Woven fiberglass mat coated with polymer ULTRACLAD® SBS 101 lb. modified asphalt and surfaced with aluminum, copper or stainless steel foil. RUBEROIDMOD 60 lb. kegs SEBS modified asphalt Asphalt, Asphalt L & Asphalt P RUBEROIDO 39.37" (1 meter) ASTM D4601 Premium glass fiber reinforced SBS-modified Modified Base Sheet Wide. Type II, Type base sheet: G2 BUR Ruberoid® Mop 39.37" (1 meter) ASTM D 6222 Non -woven polyester mat coated with Granule Wide ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. Ruberoid® Torch 39.37" (1 meter) ASTM D 5147 Heavy duty, polyester reinforced, asphalt Smooth Wide modified bitumen membrane. Ruberoid® Torch Plus 39.37" (1 meter) , ASTM D 6222 Heavy duty, polyester reinforced, asphalt (Granule) Wide ASTM D 5147 modified bitumen membrane. Ruberoid® Torch 39.37" (1 meter) ASTM D 6222 Asphalt impregnated, coated felt, surfaced Granule Wide ASTM D 5147 with mineral' granules. Ruberoid® Torch FR 39.37" (1 meter) ASTM D 6222 Heavy duty;.polyester reinforced, coated with Wide ASTM D 5147 fire retardant asphalt modified bitumen membrane, granule surface. NOA No: 03-0430.14 ffs.X{ Expiration Date: 11/06/08 Approval Date:10/31/03 Page 3 of 28 Test Product Product Dimensions Specification Description Ruberoid® Mop Plus 39.37" (1 meter) ASTM D 6164 Non -woven polyester mat coated with (Granule) Wide ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. Ruberoid® Mop FR 39.37" (1 meter) ASTM D 6164 Non -woven polyester mat coated with fire - Wide ASTM D 5147 retardant, polymer modified asphalt surfaced with mineral granules. Ruberoid® 20 39.37" (1 meter) ASTM D 6163 SBS modified asphalt base sheet reinforce Wide ASTM D 5147 with a glass fiber mat. Ruberoid® 30 39.37" (1 meter) ASTM D 6163 Non woven fiberglass mat coated with Wide ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. Ruberoid® 30 FR 39.3T' (1 meter) ASTM D 6163 Non woven fiberglass mat coated with fire Wide ASTM D 5147 retardant, polymer modified asphalt and surfaced with mineral granules. Ruberoid® Mop 170 39.3T' (1 meter) ASTM D 6164 Non -woven polyester mat coated with fire FR Wide ASTM D 5147 retardant polymer modified asphalt surfaced with mineral granules. Vent Stacks (metal PA 100(A) One way valve vent used to relieve built-up and plastic) ASTM D 1929 pressure within theroof system. GAF Vent ASTM D 635 Stacks are available in metal or plastic. APPROVED INSULATIONS: TABLE 2 Product Name Product Description GAFTEMP Isotherm RA, RN & Polyisocyanurate foam insulation Composite GAFTEMP® Composite A & N Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. (BMCA)GAFIEWO Fiberboard Fiberboard insulation. EnergyGuard Perlite Perlite insulation board. EnergyGuard Recover Board EnergyGuard High Density Fiberboard PYROX White Line ACFoam I, Il & Composite ISO 95+ Perlite recover board High density wood fiberboard insulation. Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Manufacturer (With Current NOA) GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. Apache Products Co. Apache Products. Co. Atlas Energy Products Firestone Building Products, Inc. C. NOA No: 03.0430.14 Expiration Date: 11/06/08 Approval Date:10/31/03 Page 4 of 28 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Wood Fiber Wood fiber insulation board generic High Density Wood Fiberboard Wood fiber insulation board generic Perlite Insulation Perlite insulation board generic Pelite/Urethane Composite Perlite / urethane composite board generic insulation Type X Gypsum Fire resistant rated gypsum generic Dens Deck Water resistant gypsum board G P Gypsum Corp. ENRGY 2 & ENRGY 2 PLUS, Polyisocyanurate foam insulation Johns Manville U1traGard Gold FiberGlass Roof Insulation Glass fiber/Mineral fiber insulation Johns Manville ISORoc Polyisocyanurate foam / rockwool Johns Manville composite insulation Stmctodek Wood fiber insulation board Masonite. Paroc Base Board, Paroc Cap Rockwool insulation. Partek, Inc. Board Multi -Max, FA Polyisocyanurate roof insulation RMax, Inc. APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. GAFTITE® (Drill-Tec®) Insulation fastener for GAF Materials Corp. #14 Heavy Duty Roofing_ steel, wood & concrete Fastener decks. 2. GAFTITE® (Drill-Tec®) Pre -assembled GAFTITE GAF. Materials Corp. ASAP Fasteners and metal and plastic plates. 3. GAFTITE® (Drill-Tec®) Base sheet fastening GAF Materials Corp. Base Sheet Fastener and assembly. Plate 4. Galvalume Plates (Drill- Round galvalume stress 3" and 3/i' GAF Materials Corp. Tee® Metal) plates. S. Polypropylene Plates Round polypropylene 3" and 31/2" GAF Materials Corp. (Drill-Tec® Plastic) stress plates. 6. Dekfast Fasteners #14 & Insulation fastener for Construction Fasteners #15 wood, steel and concrete Inc. decks NOA No: 03.0430.14 is Expiration Date: 11/06/08 Approval Date:10/31/03 Page 5 of 28 APPROVED FASTENERS: Fastener Product Number Name 7. Dekfast Hex Plate 8. Dekfast Lock Plate 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. #14 Roofgrip Fasteners Hextra Plus Metal Plate TABLE 3 Product Manufacturer Description Dimensions (With Current NOA) Galvalume hex stress 2 7/8" x Construction Fasteners plate. 3 1/4" Inc. Polypropylene locking 3" x 31/4" ' Construction Fasteners plate. Inc. Insulation fastener for ITW Buildex Corp. wood and steel. Pre -assembled Insulation ITW Buildex Corp. fastener and 3" metal plate Galvalume stress plate. 3" round JTW Buildex Corp. 3" square Gearlok Plastic Plate Polypropylene round plate 3.2" ITW Buildex Corp. Olympic Fastener #14 Insulation fastener Olympic Manufacturing Group, Inc. Fluted Nail (Con-Tite) Insulation fastener Olympic Manufacturing Group, -Inc. Olympic Fastener ASAP Pre -assembled Insulation Olympic Manufacturing fastener and plate Group, Inc. Olympic Polypropylene Polypropylene plastic 3.25" round Olympic Manufacturing plate Group, Inc. Olympic G-2 3" round galvalume AZ,55 3.5" round Olympic Manufacturing steel plate Group, Inc. Olympic Standard 3" round galvalume AZ50 3" round Olympic Manufacturing steel plate Group, Inc. Rawl Drive Insulation fastener for Powers Fasteners, Inc. concrete decks Rawl Plate 3" round galvalume AZ55 3" round Powers Fasteners, Inc. steel plate HD Insul-Fixx Fastener Insulation fastener for SFS/Stadler concrete decks Insul Fixx S Plate 3." round galvalume AZ50 3" round SFS/Stadler steel plate Insul-Fixx P Plate 3" round polyethylene 3" round SFS/Stadler stress plate Tru-Fast Fasteners Insulation fastener for Tru-Fast concrete decks NOA No: 03-0430.14 Expiration Date: 11/06/08 Approval Date:10/31/03 Page 6 of 28 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 25. Tru-Fast MP-3 Galvalume AZ50 steel 3.23" round Tru Fast plate 26. Tru Fast Plastic Plate Polyethylene plastic plate. 3.04" round Tru Fast EVIDENCE SUBMITTED: Test AQencv Test Identifier Description Date Factory Mutual Research Corp. FMRC 1996 Current Insulation 01.01.96 Attachment Requirements Factory Mutual Research Corp. J.I.2B8A4.AM Wind Uplift 07.02.97 J.I.3B9Q1.AM FMRC 44704 01.08.98 J.I.ODOA8.AM 07.09.99 Factory Mutual Research Corp. J.L OD1A8.AM Wind Uplift 07.29.94 J.I.OY9Q5.AM FMRC 4470 - PA 114 04.01.98 a NOA No: 03-0430.14 Y Expiration Date: 11/06/08 Approval Date:10/31/03 Page 7 of 28 Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type D(1): Anchor sheet adhered with approved asphalt; all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe Pyrox, White Line, ISORoc, UltraGuard Gold, ENRGY 2, GAFTEMP® Isotherm R, GAFTEMP Isotherm RA, GAFTEMP Isotherm RN, ENRGY 2 Plus, GAFTEMP Composite, GAFTEMP Composite A, GAFTEMP Composite N, Iso 95 + Minimum 1" thick N/A N/A High Density Wood Fiber, EnergyGuard High Density Fiberboard Perlite, EnergyGuard PERLITE, EnergyGuard Recover Board Minimum Vz" thick N/A N/A Paroc Minimum -/4" thick N/A- N/A Wood Fiber, EnergyGuard Fiberboard Minimum 1" thick N/A N/A Fiberglas Minimum 15/16" thick N/A N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of base sheet. All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires eithera ply of GAFGLAS STRATAVENTO EliminatorTM Perforated laid dry or a layer of Eq. ergyGuard PERLITE or wood fiber overlay board on all isocyanurate applications. Anchor Sheet: (Optional) Install one ply of GAFGLASO #75, GAFGLAS #80 Ultima a Base Sheet, GAFGLAS® PLY 4®, GAFGLAS F1exply'm 6 GAFGLAS® STRATAVENT@ Eliminator Perforated, RUBEROID Modified Base Sheet or RUBEROID® 20 directly to primed deck adhere with any approved mopping asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS #80 UltimaTM, GAFGLASO PLY 4®, GAFGLAS F1exPlyTM GAFGLAS® STRATAVENT® Eliminator Perforated, RUBEROID Modified Base Sheet or RUBEROID® 20 directly to the insulated substrate. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No: 03-0430.14 Expiration Date: 11/06/08 Approval Date:10/31/03 Page 22 of 28 Ply Sheet: Two or more plies of GAFGLAS® Ply 40 or GAFGLAS F1exPly 6 ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Surfacing: (Required if no cap sheet is used) Install one of the following: ' 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. GAF Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. or GAF WeatherCoae Emulsion at 3 gal./sq. Maximum Design Pressure: -90 psf (See General Limitation #9.) NOA No- 03-0430.14 { Expiration Date: 11/06/08 Approval Date:10/31/03 Page 23 of 28 CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant. •%rip NOA No: 03-0430.14 Expiration Date: 11/06/08 Approval Date:10/31/03 Page 27 of 28 GENERAL LDaTATIONS: 1. +01 3. 4. 5 7. 8. 9. 10. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20401bs./sq., or mechanically attached using the fastening pattern of the top layer All standard panel sizes are acceptable for mechanical attachment. When applied in approved. asphalt, panel size shall be 4' x 4' maximum An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not'acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt, application of either system shall be at a minimum rate of 121bs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. insulation attachment shall not be acceptable. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system Should the fastener resistance be less than that equired, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulatioi -and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (Whpn this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) All attachment and sizing of perimeter na.ilers, metal profile, and/oX flashing termination designs shall conform with Roofmg Application Standard RAS 111 and applicable wind load requirements. The maximum designed pressure limitation.listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No: 03-0430.14 Expiration Date: 11/06/08 Approval Date:10/31/03 Page 28 of 28