Loading...
HomeMy WebLinkAboutNOAMM I� DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL.DIVISION NOTICE OF ACCEPTANCE I Curries Division of AADG, Inc. 150212`s Street NW Mason City, IA 50401 SCANNED BY St. Lucie GooMy MIAMI-DADE COUNTY, FLOPMA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 WAN% FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 1 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Curries Steel Store Front System APPROVAL DOCUMENT: Drawing No. RD0254, titled "Curries Steel Store Front System", sheets 1 through 12 of 12, prepared by manufacturer, dated 11/20/03 and last revised on 09/24/04, signed and sealed by Richard Boyette, P. E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and . following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its -entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA, consists of this page, evidence sheet E-1, as well as, approval document mentioned above. The submitted documentation was reviewed by Herminio F. Gonzalez, P.E., Director, BCCO NOA No 04-0622.05 Expiration Date: November 04, 2009 / Approval Date: November 04, 2004 ` Page 1 Curries Division of AADG. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. RD0254, titled "Curries Steel Store Front System", sheets 1 through 12 of 12, prepared by manufacturer, dated 11/20/03 and last revised on 09/24/04, signed and sealed by Richard Boyette, P. E. B. TESTS 1. Test -reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC; TAS 203-94 6) Forced Entry Test, per FBC 24113.2.1 and TAS 202-94 along with marked -up drawings and installation diagram of steel storefront system, prepared by Architectural Testing, Test Reports No. ATI-0244412.01, dated September 25,2003, signed & sealed by Joseph A. Reed, P. E C. CALCULATIONS 1. Anchor Calculations, ASTM- E 1300, and structural analysis, dated 04/15/2004 and revised on 09/07104, prepared, signed and sealed by Richard Boyette, P.E. D. QUALITY ASSURANCE BY 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1., Notice of Acceptance No. 03-0225.10 issued to Glasslam NGI Inc., for "Safety Plus R Laminated Glass", dated 08/07/2003 and expiring on 08/07/2008. F. STATEMENTS 1. Statement letter of conformance and no financial interest, dated June 17, 2004, signed and sealed by Nelson Kraschel. 2. Statement letter of compliance and no financial interest, dated November 18, 2003, signed and sealed by Richard Boyette, P.E. G. OTHER 1. Letter from the consultant stating that the product is in compliance with the Florida :Building Code (FBC). erminio F. Gonzalez, P.E. Director, Building Code Compliance Office NOA No 04-0622.05 Expiration Date: November 04, 2009 Approval Date: November 04, 2004 E-1