Loading...
HomeMy WebLinkAboutPRODUCT INFORMATION - STEEL DOORr. O O N a Co O O N LO O N M O 99 7/8" WIDTH -7 47 3/4" DOOR WIDTH ------ - Le / 12 i' �� \•� 3 p j � 12 ! { w Z , 00 In J J O too I .% 19 6 11 7 �,� D 6 M 5 ELEVATION - A - 3 EXTERIOR VIEW (OUTSWING) 8 HARDWARE PACKAGE: 8- 4 1 /2" x 4 1 /2" x 0.134" PLAIN STEEL TEMPLATE HINGES 2 - VON DUPRIN 9827EO RIM . EXIT DEVICE WITH #229 STRIKE 4 - IVES SB453 SURFACE BOLTS 2 - UNIQUE SASH DOOR SWEEP #2100 1 - PEMKO 177A SADDLE THRESHOLD or PEMKO 2051AT THRESHOLD DESIGN PRESSURE POSITIVE +65 PSF NEGATIVE -65 PSF 114 CoC. O O N a ca O CV M O _ :tip �•�4, '- =i:;: •- 47 3/4" NET DOOR WIDTF 4 99 7/8" 47 3/4 _I- -r---;--- 7-1-/2" - - ELEVATION - B - EXTERI 8 OR VIEW (OUTSWING) % Approv��.00�wltt6t� p p HARDWARE PACKAGE: 8- 4 1./2" x 4 1 /2" x 0.134" PLAIN STEEL TEMPLATE HINGES �a J AS I F! 1 - 4 - 2 - 1 - VON-DUPRIN 9875EO MORTISE EXIT DEVICE IVES SB453 SURFACE .BOLTS UNIQUE SASH DOOR SWEEP #2100 PEMKO 177A SADDLE THRESHOLD or PEMKO 2051AT THRESHOLD KELVYN WHITFIELD, P.E. MANUFACTURER: 1002 N.E. 116TH STREET MIAMI, FL 33161 Ulm sensteelimors 4950, Hickmore, St -Laurent, Quebec Canada, H4T 1K6 Tel: (514) 733-3562 FLORIDA No. 24140 rn 1 AS PER BCCO NOTES JUN 24/05 REV. NO. DESCMPION DATE RODUCT: SHEET NO.: 8080 DOUBLE DOOR SYSTEM 1 Of 5 GENSTORM SERIES TLE: DWG NO.: ELEVATIONS GS-10005 GALE: DRAWN BY: APPROVED BY. DATE: NONE AG I APR 2005 _ M L ' Qu � J 99 7/6- 95 7/8" FRAME OPENING WIDTH MASONRY WALL CONSTRUCTION \I NO ANCHORS REQUIRED. i ; •,� HEAD JAMB MUST BE FILLED WITH GROUT. ., a IS obi EQUAL EQUAL i ',4 • 5/16.0 TAPCONS, 1 1/2" EMBED. (3) PLACES • `� 3/4' x 1 1/2" x 1/16' ALUMINUM TUBE 14' LG, c I I m N 99 7/e" rTwm 95 7/8' MASONRY WALL CONSTRUCTION \I • te• te• e• te• is ;L . ` r, = to • • •~ i Wj EQUAL EQUAL ' to 5/16"0 TAPCONS, 1 1/2" it ,s m CD ' EMBED. (3) PLACES •`{ 3/4" x 1 1/2' x 1/16. ' ALUMINUM TUBE 14' LG. s. 6' 12' I 12" i 12" I 12- I 1:r I 12" I 12' 16"I 1 1/4 TAPCONS (I12" 1 1/4' EMBED. O 12' C/C (6) PLAt'ES FLOOR ANCHOR P PER JAMB. (1) #14 TAPCON ANCHORAGE LAYOUT FLOOR ANCHOR (1) PER JAMB, (1) #14 TAPCON 1 1/4" MIN. EMBED. MASONRY WIRE ANCHORS 1 1/4" MIN. EMBED. SEE DETAIL "0" SEE DETAIL "D' FRAME FILLED 0.173" 0 MASONRY WIRE WITH GROUT MIN. ANCHOR (7) PER JAMB 1200 PSI REQ'D. SEE DETAIL ON PAGE 5 OF 5. 8" MIN. EMBEDMENT MAX. JECTION DETAIL "A" RAME (1) #14 TAPCON SCREW PER JAMB I ' MIN. EMBED. DETAIL "D" �y • . �jr�,/�s•1� .E 6-1 12' I 12' I 12' 12' I 12" I 12- I 1Y 6"I 4 i T _ ^ ANCHORAGE LAYOUT — EMA ANCHOR ® EACH SCREW. SEE DETAIL ON PAGE 5 OF 5. 1 /�4".,1 1 /4" MIN. EMB. MAX.( O :Lc• .L •i�;. 5/16" 0 x 5" TAPCON SCREWS (4) PER JAMB REQ'D DETAIL "B" KELVYN WHITFIELD, P.E. (MANUFACTURER: 1002 N.E. 116TH STREET MIAMI, FL 33161 r D 7wb�5 FLORIDA No. 24140 99 7/8' 59EM FRAME 95 7/8" FRAM WOOD STUD CONSTRUCTION 14Pta• ta• tr is ta• �,. Z W O � o EQUAL EQUAL ro ID 5/16"0 TAPCONS, 1 1/2" 0 EMBED. (3) PLACES 3/4' x 1 1/2" x 1/16" ALUMINUM TUBE 14" LG v I I 9 TAPCONS (nW) iv I I I I I i I I 11/4"0 TAPCONS (ITW) EMBED. ® 12" 8' 14' 12" 12' 12' 12' 12" _I 1Y 16' 1 1/4' EMBED. O 12" s) PLACES I I 7I f 0/0 (6) PLACES FLOOR ANCHOR (1) PER ANCHORAGE LAYOUT CON iON1EE�4"MIM D. TAPCON SCREWS IN WOOD SEE DETAIL V — EMA ANCHOR 0 EACH SCREW. 1 " 9 9 SEE DETAIL ON PAGE 5 OF 5, 1 /2 I 7 I 11 /2 1/4" 2" IN. EMB. MAXI I - 5/16" 0 x 5" TAPCON SCREWS (4) PER JAMB REQ'D DETAIL ttC" sensteelimors 4950, Hickmore, St -Laurent, Quebec Canada, H4T 1K6 Tel: (514) 733-3562 7�2 16 GAUGE (0.060")GALVANNEALED STEEL, TENSILE STRENGTH 48 KSI iv 1 1/2" .T. 2 7/16" .T_ 1 15/16" 00 1-1 FRAME PROFILE 1 1 AS PER BCCO NOTES JUN 24/05 REV. NO. I DESCRIPTION DATE RODUCT: SHEET NO.: 8080 DOUBLE DOOR SYSTEM 2 of 5. GENSTORM SERIES ITL . DWG NO.: ANCHORAGE LAYOUT GS-10005 CALE: DRAWN BY. APPROVED BY: DATE: NONE I AG I APR 2005 FOR FRAME ANCHORAGE LAYO NfiINUOUS GE-SILICC PAGE 2 OF 5. CAULKING BOTH SIDES ' 1 INSTALL STRIKE 'WITH (2) #10 x 4" SCREWS FOR TIMBER CONSTRUC1ION OR (2) #10 x 1-1/4" SCREWS FOR MASONRY CONSTRUCTION VERTICAL ROD LATCH SHOWN. FOR SURFACE BOLT SEE DETAIL 6 ON PAGE 4 OF 5 INSTALL LATCH WITH ' (2) #12 x 1/2" MACHINE SCREWS. SEAL ALL SCREWS WITH CE SILICONE II CAULKING I' 4 HEAD JAMB DETAIL 3 INSTALL LATCH WITH (2) #12 x 1 /2" MACHINE SCREWS. SEAL ALL SCREWS WITH GE SILICONE II CAULKING INSTALL STRIKE WITH — (2) #10 x 4" SCREWS FOR TIMBER CONSTRUCTION OR (2) #12 x 3 1 /2" SCREWS FOR MASONRY CONSTRUCTION SEAL SILL TO - FLOOR AND FRAME WITH GE SILICONE II CAULKING VERTICAL ROD LATCH SHOWN. FOR SURFACE BOLT SEE DETAIL 7 ON PAGE 4 OF 5 SEAL DOOR SWEEP TO DOOR WITH GE SILICONE II CAULKING #6 x 1" TECH SCREWS ® 6" C/C 1 /4" 0 TAPCON 1 EMBED. 0 12" C/C (6 PLACES). " r 3/4" x 1 1/2 fix. 1/16" 5/16" 0 TAPCONS, 1 1/2" EMBED. ALUMINUM TUBE 14" LG. (3 PLACES) SEE PAGE 2 OF 5 FOR SEE PAGE 2 OF 5 FOR LOCATION. LOCATION 5 SILL DETAIL Q3 LAYOUT AND DETAILS SEE PAGE 2 OF 5. INSTALL HINGE TO DOOR/­1 FRAME WITH (4) #12-24 X 1 /2" SCREWS. SEAL HINGE AND SCREWS WITH GE SILICONE II CAULKING 'I 1 HINGE JAMB DETAIL INSTALL EXIT DEVICE TO DOOR WITH (6) #9X1" & (2) #14X1" MACHINE SCREWS. SEAL ALL SCREWS WITH GE SILICONE II (5-, CAULKING WITH (6) #9X1" & (2) #14X1" MACHINE SCREWS. SEAL ALL SCREWS WITH GE SILICONE II CAULKING 4 #6 x 1" RE TECH SCWS - ® 6" C/C. SEAL SCREWS WITH GE SILICONE II CAULKING WITH (6) #9X1" & (2) #14X1" MACHINE SCREWS. SEAL ALL SCREWS WITH GE SILICONE II - -CAULKING- - - ---- - - - ---- - - #12-14 x 7/8" SCREWS --I SEAL ASTRAGALS TO DOOR 12" C/C. SEAL SCREWS WITH GE SILICONE II CAULKING WITH GE SILICONE II CAULKING 2 LOCK EDGE DETAIL Q3� too '01 #6 x 1" TECH SCREWS ® 6" C/C. SEAL SCREWS WITH GE SILICONE II CAULKING #12-14 x 7/8" SCREWS -3 \ p 0 18 12" C/C. SEAL SCREWS WITH GE SILICONE II CAULKING SEAL ASTRAGALS TO DOOR WITH GE SILICONE II CAULKING 3 LOCK EDGE DETAIL 3 KELVYN WHITFIELD, P.E. IMANUFACTURER. 1002 N.E. 116TH STREET MIAMI, FL 33161 of�oS FLORIDA No. 24140 jjj sensteelmoors. 4950, Hickmore, St -Laurent, Quebec Canada, 1­14T 1K6 Tel: (514) 733-3562 1 /2" 9"x10GA INFORCEMENT i 6 \ND TAPPED • 2-24 SREWS I ®s HINGE CUTOUT DETAIL ON DOOR AND FRAME 1 1 AS PER BCCO NOTES JUN 24/05 P". N0. I DMCFJP170N DATE PRODUCT: SHEET NO.: 8080 DOUBLE DOOR SYSTEM 3 of 5 GENSTORM SERIES TITLE: DWG NO.: DETAILS IGS-10005 NONE I BY APPROVED BY: DATE: AG I I APR 2005 ;EE DETAIL 8 & 9 (2) #14 x 1 1/4"—J MACHINE SCREW THRU BOLTS C/W EXTERIOR GASKET (2) #10 x 1 1/2" TECH SCREWS N.B.: SEAL ALL SCREWS WITH GE SILICONE II CAULKING FOR FRAME ANCHORAGE LAYOUT AND DETAILS SEE PAGE 2 OF 5. CONTINUOUS GE SILICONE II CAULKING BOTH SIDES SEAL METAL DUST BOX TO FRAME WITH GE SILICONE II CAULKING �i 6 HEAD JAMB DETAIL 4 (2) #10 x 1 1/2 = TECH SCREWS O (2) #14 x 1 1 /4" MACHINE SCREW THRU BOLTS C/W EXTERIOR GASKET SEAL SILL TO FLOOR AND FRAME WITH GE SILICONE II n - CAULKING N.B.: SEAL ALL SCREWS WITH GE SILICONE II CAULKING ITEM PART NO.. MATERIAL CITY IDESCRIPTION 1 ------ STEEL (FLUSH) 2 20 GA EXTERIOR AND INTERIOR FACE SHEETS 2 - - ------ - S T-E-E-L-(1-6-G-A-). 1 16-GA-S-T-E-E-L- F R-A-M-E -- - — 3 HBB17SC15 "HARDWARE" 8 4 112 X4 1/2 X.134 BUTT HINGE 4 9627EO "HARDWARE" 2 VON DUPRIN 9827EO RIM EXIT DEVICE WITH #229 STRIKE 5 9875EO "HARDWARE" 1 VON DUPRIN 9875 MORTISE EXIT DEVICE 6 SB453 "HARDWARE" 4 IVES SB453 SURFACE BOLT 6 2051AT ALUMINUM 1 PEMKO 2051ATTHRESHOLD WITH VINYL INSERT 9 FR1100 STEEL (18 GA) ,1 4 7/8" STRIKE PLATE REINFORCEMENT 10, DC1000 STEEL (18 GA) 2 DOOR CLOSER REINFORCEMENT 11 CH3601 STEEL (18 GA) 4 DOOR END CHANNEL 12 DR1000 STEEL (18 GA) 2 RIM EXIT DEVICE REINFORCEMENT 13 DR1010 STEEL (18 GA) 1 MORTISE EXIT DEVICE REINFORCEMENT 14 HR1030 STEEL (10 GA) 16 HIGH FREQUENCY HINGE REINFORCEMENT 15 DR1700 STEEL (10 GA) 2 MORTISE LOCK EDGE REINFORCEMENT 16 ------ VINYL 2 VINYL C A P 17 P387 NEOPRENE 1 PEMKO P387 ADHESIVE BACK NEOPRENE WEATHERSTRIP 18 ------ KRAFT PAPER HONEYCOMB 2 CASCADE ENVIROPAC 1" CELL KRAFT PAPER HONEYCOMB 19 AS1060 STEEL (10 GA) 1 2" FLAT ASTRAGAL 20 375CR ALUMINUM 1 JPEMKO 375CR ASTRAGAL WITH SPONGE NEOPREN 21 ------ STEEL (10 GA) 2 2" x 4 1/2" REINFORCEMENT 22 ------ STEEL (10 GA) 1 2" x 6 3/4" REINFORCEMENT 23 DR1700M STEEL (10 GA) 4 MORTISE SURFACE OL RIK REI OR r ENT 24 1 FR1100M STEEL (18 GA) 2 DUST BOX .328" x 1" SLOT — THROUGH HEAD AND REINFORCEMENT FOR IVES #453 SURFACE BOLT SEAL DOOR SWEEP TO DOOR WITH GE SILICONE II CAULKING .6 x 1" TECH, SCREWS D 6" C/C • • " Q Q• •CONCR£TE 1 /4" 0 TAPCON, 1 EMBED. ® 12" C/C (6 PLACES). 3/4" x 1 1/2" 5/16" 0 TAPCONS, 1 1/2" EMBED. ALUMINUM TUBE 14" LG. AppW"dwsew*ftv41b1a (3 PLACES) SEE PAGE 2 OF 5 FOR SEE PAGE 2 OF 5 FOR ftly. LOCATION. LOCATION 7 SILL' DETAIL 3/4" X 2 7/8" - CUTOUT FOR IVES SB453 MORTISE STRIKE Q 3/8" 5/16.0 X 5" TAPCON u SCREWS. SEE ANCHORAGE .328" x 1. SLOT THROUGH — LAYOUT ON PAGE 2 OF 5 HEAD AND REINFORCEMENT FOR IVES #453 SURFACE BOLT 8 SURFACE BOLT STRIKE 4 PREP OPTION "A" KELVYN WHITFIELD, P.E. IMANUFACIURER: 1002 N.E. 116TH STREET II MIAMI, FL 33161 FLORIDA No. 24140 6 ~71/2� IMP 2" 4" 4" i 5/16.0 X 5" TAPC 23 SCREWS. SEEANCHORAGE 23 LAYOUT ON PAGE 2 OF 5 3/4" X 2 7/8" . CUTOUT FOR IVES SB453 MORTISE STRIKE 9 MORTISE SURFACE BOLT 4 STRIKE PREP OPTION "B" irn Uj s limors 4950, Hickmore, St -Laurent, Quebec Canada, H4T 1K6 Tel: (514) 733-3562 3/8" 1 AS PER BCCO NOTES JUN 24/05 REV. NO. DER M110N DAIE RODUCT SHEET NO.: 8080 DOUBLE DOOR SYSTEM 4 of '5 GENSTORM SERIES iTLE. DETAILS AND DWG NO.: BILL OF MATERIALS GS-10005 CALE: DRAWN. BY: APPROVED BY: DATE: NONE I AG I APR 2005 I 4 1/2" 15 4 1/2" 10" 16 -- — — - - -- - °� - - - 0.173" 0 MASONRY —r ? "RE ANCHOR 2 1/8" 2 1/2"-18 GA 2 1/2"-18 GA � STEEL CAP STEEL CAP18 tt '� 18 GA FLOOR ANCHOR PROJECTION • TYPICAL MASONRY 18" " RETAINING PROJECTION GA EMA [7k P18AWELDED NCHOR WELDED TO FRAME WIRE ANCHOR 1 18 CLIPS TO FRAME D D D D 10 GA HINGE 2" 18 GA FLOOR REINFORCEMENT ANCHOR 1 3/4" 2 1/2"-18 GA 18 GA EMA '• a' x D 2 1/2"-18 GA D STEEL CAP ANCHOR k x 17 STEEL CAP ® Q xx o p 2 1/2"-18 GA 2 1/2"-18 GA + x \ STEEL CAP D STEEL CAP '' 3 5/8" 1 1/2" k 0 9" D O 4 3/8" 5 1 /4" 3 5/8" 1 i /2" .40 oy PART No.: DC1000 PART No.: DR1010 TYPICAL EMA TYPICAL FLOOR & DR1000 ANCHOR ANCHOR 1 1/4" 18 GAUGE HOLES DRILLED 11 REINFORCEMENT 1 1/8" AND TAPPED FOR 1 1/4" #12-24 SCREWS 19 18 GAUGE 1 1/2" 'r 2 5/16" 0 11 REINFORCEMENT + x 3 1/2 4 +" 10 GAEDGETISE + Q .r 10 GA SURFACE 2 1 /4 BOLT MORTISE STRIKE k �, REINFORCEMENT REINFORCEMENT /4" 23 3 1/2" 6 3/4" HOLE DRILLED HOLES DRILLED AND TAPPED FOR L DRILLEDOLE AND TAPPED FOR #10-24 SCREW AND TAPPED FOR 9/16" '( 1 1/16" 12-24 SCREWS 1 2 1 #12-24 SCREW PART No.:. FR1100M PART No.: DR1700M PART No.: DR17.00 PART No.: HR1030 PAND KELVYN WHITFIELD, P.E. MANUFACTURER: ES DRILLED 1002 N.E. 116TH STREET1 1/16" TAPPED FOR A���1NQASMR BCCO NOTES JUN u� 05 -24 SCREWS MIAMI, FL 33161 SHEET NO.: PART No.: FR1100 N` o elDoors PRonuc8080 DOUBLE DOOR SYSTEM 5 of 5 Mhwt-DwkptYtdaetColud GENSTORM SERIES Dlvirrie 4950, Hickmore, St -Laurent, Quebec TITLE. DWG NO.: By Canada, H4T 1K6 Tel: (514) 733-3562 MISCELLANEOUS DETAILS GS-10005 ( SCALE DRAWN BY: APPROVED BY: DATE: FLORIDA No. 24140 NONE AG I APR 2005 40" AALL FRAMEWDT, 35 3/4" :T DOOR WIDTH 4 °R - 5 °-1 2 4 F F- _ �_ _ W M O Q 0 U- W J Z Q of x \ O � M co LO 00 0 M 10 6 4 ELEVATION - A - EXTERIOR VIEW (OUTSWING) HARDWARE PACKAGE: 3— 4 1 /2" .x 4 1 /2" x 0.134" PLAIN STEEL TEMPLATE HINGES 1 — DOREX FC 10 SERIES LEVER LOCK 1 — DOREX FHA51 DEADBOLT 1 — UNIQUE SASH DOOR SWEEP #2100 1 — PEMKO 177A SADDLE THRESHOLD or PEMKO 2051AT THRESHOLD DESIGN PRESSURE POSITIVE +80 PSF NEGATIVE —80 PSF M 0 0 40" 0 RALL FRAME Multi 35 3/4" NET DOOR WIDTH 7- 5 - p r ' 14 r 13 8 f I v J / 15 f 3 4 m CD w w 2 = W M O 0 _ F- J W --� Z Q \ O 00 000 M M 0 0 , 35 3/4" , NET DOOR WIDTH 7 5 p 14 13 8 r'� v rr , v 'f 16 ri i 7 I . 8 14 f— I J W Q z x �i �t x M 10 5 M 10 5 ►i ELEVATION - B - ELEVATION - C - EXTERIOR VIEW (OUTSWING) EXTERIOR VIEW (OUTSWING) HARDWARE PACKAGE: �pp"'°1� HARDWARE PACKAGE: 3— 4 1 /2" x 4 1 /2" x 0.134" PLAIN 33 — 4 1 /2" x 4 1 /2" x 0.134" PLAIN STEEL TEMPLATE HINGES NOSTEEL TEMPLATE HINGES 1 — VON DUPRIN 98EO RIM EXIT DEVICE !1'lha 1 — VON DUPRIN 9875EO MORTISE EXIT DEVICE A WITH #229 STRIKE fthimn2 — IVES SB453 SURFACE BOLTS 2 — IVES SB453 SURFACE BOLTS BY 1 — UNIQUE SASH DOOR SWEEP' #2100 1 — UNIQUE SASH DOOR SWEEP #2100 1 — PEMKO 177A SADDLE THRESHOLD 1 — PEMKO 177A SADDLE THRESHOLD or PEMKO 2051AT THRESHOLD or PEMKO 2051AT THRESHOLD N KELVYN WHITFIELD, P.E. MANUFACTURER: 1002 N.E. 116TH STREET 1 AS PER BCCO NOTES JUN 24 05 MIAMI, FL 33161 / REV. NO. DESMPnON DATE LA PRODUCT: S i D OOIn s..1' 3070 SINGLE .DOOR SYSTEM SHEET NO.: GENSTORM SERIES 1 of 6 4950, Hickmore, St —Laurent, Quebec TITLE: DWG NO.: �j Canada, H4T 1K6 Tel: (514) 733-3562 ELEVATIONS GS-10004 a 71 0+ SCALE DRAWN BY: APPROVED BY. DATE: FLORIDA No. 24140 NONE I AG MAR 2005 DODaS Mk 1 , , l 1-4, IF 30 22 2%r �L41 25, 281 IA,. M IAM I-D1ADE 1% MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MWAI, FLORIDA 33130-1563 ) 3'1 - 9-01 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) www.buildinycodeonline.com _ Genteel Doors, Inc. 4950 Hickmore Street Ville St. Laurent, Quebec, Canada 114T 1K6 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements.of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series Genstorm 3070 Steel Single Door System APPROVAL DOCUMENT: Drawing No. GS-10004, titled "3070 Single Door System Genstorm Series", sheets 1 through 6 of 6, prepared by the manufacture, dated 03/2005, signed and sealed by Kelvyn Whitfield, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING:. Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control -Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,* then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence page E-1,'as well as approval document mentioned above. The submitted documentation was reviewed by Herminio F. Gonzalez, P.E., Director, BCCO NOA No 05-0127.10 Ib Expiration Date: August 04, 2010 o y Approval Date: August 04, 2005 Page 1 _ Genteel Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED y A. DRAWINGS 1. Manufacturer's die drawings and sections. awing- -—G'S--1004,—t`tIi e�"3070-Single Door System Genstorm Series", sheets 1 through 6 of 6, prepared by the manufacture, dated 03/2005, signed and sealed by Kelvyn Whitfield, P.E. B. TESTS L . Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94 along with marked -up drawings and installation diagram of steel outswinging door, prepared by Intertek Testing Services NA LTD., Test Reports No. ITS-3058370- SINGLE, dated 12/09/04, signed and sealed by Stephen J. Emerman, P. E. C. CALCULATIONS 1. Anchor Calculations, and structural analysis, prepared by Kelvyn A. Whitfield, P.E. Consulting Engineer, dated 05/18/05, signed and sealed by Kelvyn Whitfield, P.E. 2. Revised Anchor Calculations, and structural analysis, prepared by Kelvyn A. Whitfield, P.E. Consulting Engineer, dated 07/05/05, signed and sealed by Kelvyn Whitfield, P.E. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. None F. STATEMENTS 1. Statement letter of code compliance and no financial interest, dated January 18, 2005 signed and sealed by Antonio Gervasi, P.E. G. OTHER 1. Letter from consultant stating that the'product is in compliance with the Florida Building Code (FBC). Herminio F. Gonzalez, P.E. Director, Building Code Compliance Office NOA No 05-0127.10 Expiration Date: August'04, 2010 Approval Date: August 04, 2005 E-1 r Y- 40" 40" 40" OVERALL FRAME -WIDTH - n4 35 3/4" 35 3/4" 35 3/4" NET DOOR WIDTH NET DOOR WIDTH NET DOOR WIDTH 5 -- — 7 - - 7 - 4 OR 5 5 5 -� R 3to I 3 ' "— � T � 2 14 14 14 13 2 2 13 8 2 13 8 v v 4 (1I_ \ '� I- _ 2 Lr) 4 v 5 12 � CD LO 2 CD LO 20 0 4 v w 4 v 0 'w w = 15 = = M �� 16 w = M Ld Li = Li 3 0 ¢ 3 / _ 0 Q 3 0 Q .f o� % 6 r- 0 L_ �/ 7 0 71 4 z< ��1 Wii j Z < �iy-� 1 Z < 1i oo > - 1 ` oo > x 11 ao cO \ 0 '� I I \ 0 (0 \ 0 M 3 8 20cr14 g = 9 4.EVA 6 g 8 k io 4 M io 5 10 5 to ELEVATION - D - ELEVATION - E - ELEVATION - F - EXTERIOR VIEW (OUTSWING) EXTERIOR VIEW (OUTSWING) EXTERIOR VIEW (OUTSWING) HARDWARE PACKAGE: HARDWARE PACKAGE: A rowdMlPb�iiw?Abtre HARDWARE PACKAGE: 3— 4 1 /2" x 4 1 /2" x 0.134" PLAIN 3— 4 1 /2" x 4 1 /2" x 0.134" PLAIN 3— 4 1 /2" x 4 1 /2" x 0.134" PLAIN STEEL TEMPLATE HINGES STEEL TEMPLATE HINGES pTOO bs STEEL TEMPLATE HINGES 1 — DOREX FC 10 SERIES LEVER LOCK 1 — VON DUPRIN 98EO RIM EXIT DEVICE NOAi>! 1 — VON DUPRIN 9875Ed MORTISE EXIT DEVICE 1 — DOREX FHA51 DEADBOLT WITH #229 STRIKE M 2 — IVES S8453 SURFACE BOLTS 1 —.UNIQUE SASH DOOR SWEEP.#2100 2 — IVES SB453 SURFACE BOLTS 1 — UNIQUE SASH DOOR,SWEEP #2100 1 — PEMKO 177A SADDLE THRESHOLD 1 — UNIQUE SASH DOOR SWEEP #2100 BY 1 — PEMKO 177A SADDLE THRESHOLD or PEMKO 2051AT THRESHOLD 1 — PEMKO 177A SADDLE THRESHOLD .or PEMKO 2051AT THRESHOLD or PEMKO 2051AT THRESHOLD KELVYN WHITFIELD, P.E. MANUFACTURER: 1002 Ne0l E116TH STREET MI Ljj ensteewoors 4950, Hickmore, St -Laurent, Quebec Canada, H4T 1K6 Tel: (514) 733-3562 FLORIDA No. 24140 DESIGN PRESSURE POSITIVE +80 PSF NEGATIVE —80 PSF 1 AS PER BCCO NOTES REV. NO. DESOWHON PRODUCT: 3070 SINGLE DOOR SYSTEM GENSTORM SERIES TITLE: ELEVATIONS SCALE: DRAWN BY. APPROVED BY: NONE AG JUN 24 05 DATE SHEET NO.: 2of6 DWG NO.: GS-10004 DATE: MAR 2005 MASONRY WALL MASONRY WALL WOOD STUD M U) is Z n a a U) On K = J �. Q W . W Cn Wa D: cQ tC i a\ to '.i r-0, F- x x - - — -- c� W x 2 -I O W Z a o J r . • rr. 'a Co 00IIL •S4 Z N U a to 3 Wn O m to J n O H N ao H iA yx V N Cq It _1 1_ • it --- 10 1/2' le 10 1/2" - v . FE S x = — — w s O Z w x W • z W a a O J rb d' J O tt LID co 3/16"0 TAPCONS (ITW) 1 1 /4" 3/ 6" 12" 12" 6° EMBED. ® 12" C/C 6" 12" 12" 6" 1EM FLOOR ANCHOR (1) PER FLOOR ANCHOR (1) PER JAMB (1) #14 TAMPON JAMB 1 14 TAMPON Z N a a_ to iRn c� W J n e V 0 N D_ H N iq x y V N N d• L m OF --1 li �1 m— 101111 ills Milli I II � .a '•��,R, I���I((i 16"0 TAPCONS (ITW) 1 1/4- 1 1 3/16"0 TAPCONS (ITW) 1 1/4" BED. @ 12" C/C 6" 12" 12" 6" EMBED. ® 12" C/C FLOOR ANCHOR (1) PER —/ 1 1JAMB, (1) #14 TAMPON NOTE: ITW BUILDEX TAMPON ANCHORAGE LAYOUT # ANCHORAGE LAYOUT ANCHORAGE LAYOUT 1 1/4" MIN. EMBED. 1 1/4° MIN. EMBED. 1 1/4" MIN. EMBED. APPROVED BY BCCO SEE DETAIL "D" MASONRY WIRE ANCHORS SEE DETAIL "D" TAPCON SCREWS IN MASONRY SEE DETAIL "D" TAPCON SCREWS IN WOOD N.O.A. '# 03-0114.03 FRAME FILLED 0.173" 0 MASONRY WIRE EMA ANCHOR ® EACH SCREW EMA ANCHOR ® EACH SCREW WITH GROUT MIN. ANCHOR (6) PER JAMB SEE DETAIL ON PAGE 6 OF 6 SEE DETAIL ON PAGE 6 OF 6 1200 PSI REQ'D SEE DETAIL ON 1/4" 1 1/4" MIN. EMB. 1/4" 2" IN. EMB. PAG�E.6 OF 6 MAX. �. MAX.I O ;a i/4 + 8" MIN. EMBEDMENT ` #14 x 5" TAPCON SCREWS MAX. (4) PER JAMB REQ'D JECTION DETAIL "A" DETAIL "B" RAME KELVYN WHITFIELD, P.E. (1) #14 TAPCON 1002 N.E. 116TH STREET SCREW PER JAMB MIAMI, FL 33161 A�nM M» ie� wf h the 1 1 /4" O MIN. EMBED. " lead �e eetCW �' 'v rr FLORIDA No. 24140 #14 x 5" TAPCON SCREWS (4) PER JAMB REQ'D DETAIL "C" ACTURER: Insensteeh000rs 4950, Hickmore, St —Laurent, Quebec Canada, 1-14T 1 K6 Tel: (514) 733-3562 4 7/8" 1 1/2" 18 GAUGE (0.051 ") GALVANNEALED STEEL TENSILE STRENGTH 48 KSI N 1 1 /2" •T2 7/16" 11 15/16" . to FRAME PROFILE 1 AS PER BCCO NOTES JUN 24/05 REV. NO. DE=P-n0N DATE PRODUCT: SHEET NO.: 3070 SINGLE DOOR SYSTEM 3 of 6 GENSTORM SERIES TITLE: DWG NO.: ANCHORAGE LAYOUT GS-10004 SCALE: DRAWN BY- APPROVED BY: DATE: NONE I AG I I MAR 2005 CONTINUOUS GE SILICONE II FOR FRAME ANCHORAGE LAYOUT AND FOR FRAME ANCHORAGE LAYOUT AND FOR FRAME ANCHORAGE LAYOUT AND DETAILS SEE PAGE 3 OF 6. CONTINUOUS GE SILICONE II CAULKING BOTH SIDES 5 \HEAD JAMB DETAIL �4� JAMB DETAIL SIMILIAR 14 3/16" 0 TAPCONS 1 SEAL DOOR SWEEP TO DOOR (ITW), 1 1/4" EMBED. 9 WITH GE SILICONE II ®..12" C/C 22 CAULKING SEAL SILL TO 10 FLOOR AND #6 x 1" TECH SCREWS FRAME WITH GE ® 6" C/C SILICONE II CAULKING 6 SILL DETAIL 4 3/16" 0 TAPCONS — (ITW), 1 1/4" EMBED. ® 12" C/C SEAL SILL TO 10 FLOOR AND FRAME WITH GE SILICONE II CAULKING _ -SEAL DOOR SWEEP TO DOOR WITH GE SILICONE II CAULKING #6 x 1" TECH SCREWS ® 6" C/C p CaiFCRETE' �116 mmdm SL4s' ph 6A ALTERNATE "I .� �,J4 SILL DETAIL : SEAL LOCK TO DOOR SKINS ON _BOTH_ SIDES_ WITH GE .� SILICONE II CAULKING v 7/1111 oil-Z\ INSTALL HINGE TO DOOR/ FRAME WITH (4) #12-24 X 1/2" SCREWS. SEAL HINGE AND SCREWS WITH GE SILICONE II CAULKING 1 HINGE JAMB DETAIL 4 FOR FRAME ANCHORAGE INSTALL EXIT DEVICE TO DOOR LAYOUT AND DETAILS SEEPAGE 3 OF 6. INSTA WITH (6) #9X1" & (2) #14X1" WITH MACHINE SCREWS. SEAL ALL MACHIN SCREWS WITH GE SILICONE II SCREWS CAULKING 2 CAULKIN 6 0 p21 ; C 15 CONTINUOUS GE SILICONE II CAULKING BOTH SIDES 3 LOCK JAMB DETAIL 4 KELVYN WHITFIELD, P.E. (MANUFACTURER: 1002 N.E. 116TH STREET MIAMI, FL 33161 0#40705, FLORIDA No. 24140 TINUOUS GE S11 ICOI 4E II ACING BOTH SIDES 2 LOCK. I L 4' �> JIC D00 FOR FRAME ANCHORAGE x1" LAYOUT AND DETAILS SEE AL ALL PAGE 3 OF 6. SILICONE II 2.21 C . 7 0 V 16 v CONTINUOUS, GE SILICONE II 11 CAULKING BOTH SIDES K'4"*)i LOCK JAMB DETAIL 4 Uj sensteelmoors 4950, Hickmore, St -Laurent, Quebec Canada, 1­14T 1 K6 Tel: (514) 733-3562 1 AS PER BCCO NOTES JUN 24/05 REV. NO. DESM"ON DATE IRODUCT- SHEET NO.: 3070 SINGLE DOOR SYSTEM 4 of .6 GENSTORM SERIES ML. DWG NO.: DETAILS GS-10004 CALE- DRAWN BY: APPROVED BY: DATE: NONE AG I MAR 2005 i FOR FRAME ANCHORAGE LAYOUT AND DETAILS SEE PAGE 3 OF 6. CONTINUOUS GE SILICONE II CAULKING BOTH SIDES 14 2 21 (2) #14 x,1 1/4" MACHINE SCREW THRU 13 BOLTS C/W EXTERIOR GASKET } (TECH 1SCREWS/2" N.B.: SEAL ALL SCREWS — WITH GE SILICONE II CAULKING 7 HEAD JAMB DETAIL 5 N.B.: SEAL ALL SCREWS WITH GE SILICONE It CAULKING (2) #10 x 1 1/2" TECH SCREWS 8 — (2) #14 x 1 1/4" 22 MACHINE SCREW THRU BOLTS C/W EXTERIOR GASKET 3/16" TAPCONS 14 (ITW), 1 1/4" EMBED. SEAL DOOR SWEEP ® 12" 9 C/C TO DOOR WITH GE 10 SILICONE II CAULKING SEAL SILL TO - - FLOOR AND #6 x 1" TECH SCREWS FRAME WITH GE ® 6" C/C SILICONE II CAULKING SEE DETAIL 8 FOR NOTES BILL OF MATERIALS ITEM PART NO. MATERIAL QTY DESCRIPTION 1 ------ STEEL (FLUSH OR EMBOSSED) 1 20 GA EXTERIOR AND INTERIOR FACE SHEETS 2 ------ STEEL (18 GA) 1 18 GA STEEL FRAME 3 HBB179C15 "HARDWARE" 3 4 1/2 X 4 1/2 X .134 BUTT HINGE 4 FC10 "HARDWARE" 1 DOREXFC10 SERIES LEVER LOCK 5 FHA51 "HARDWAR.E" 1 DOREX FHA51 DEADBOLT 6 98EO "HARDWARE" 1 VON DUPRIN 98EO RIM EXIT DEVICE WITH # 229 STRIKE 7 9875EO "HARDWARE" 1 VON DUPRIN 9875 MORTISE EXIT DEVICE 8 B453 "HARDVI7AR�" 2 �B�5�S�RFA E BELT 9 2100 ALUMINUM 1 UNIQUE SASH DOOR SWEEP #2100 10 2051AT ALUMINUM 1 PEMKO 2051AT THRESHOLD WITH VINYL INSERT 10A 177A ALUMINUM 1 PEMKO 177A THRESHOLD WITH VINYL INSERT 11 FR1100 STEEL (18 GA) 1 4 7/8" STRIKE PLATE REINFORCEMENT 12 FR1000 STEEL (18 GA) 1 2 3/4" STRIKE PLATE REINFORCEMENT 13 DC1000 STEEL (18 GA) 1 DOOR CLOSER REINFORCEMENT 14 CH3601 STEEL (18 GA) 2 DOOR END CHANNEL 15 DR1000 STEEL (18 GA) 1 RIM EXIT DEVICE REINFORCEMENT 16 DR1010 STEEL (18 GA) 1 IMORTISE EXIT DEVICE REINFORCEMENT 17 HR1030 STEEL (10 GA) 6 HIGH FREQUENCY HINGE REINFORCEMENT 18 DR1600 STEEL (18 GA) 2 STANDARD 2 3/4" BACKSET LOCK REINFORCEMENT 19 DR1700 STEEL (10 GA) 2 MORTISE LOCK EDGE REINFORCEMENT 20 ------ VINYL 1 VINYL CAP 21 P387 NEOPRENE 1 PEMKO P387 ADHESIVE BA RENE WEATHERSTRIP 22 ------ KRAFT PAPER HONEYCOMB I 1 ICASCADE ENVIROPA : R T PAPER HONEYCOMB 3/16" 0 TAPCONS (ITW), 1 1/4" EMBED. 0 12" C/C p OGNCRET�- 8A ALTERNATE ��5 SILL DETAIL KELVYN WHITFIELD, P.E. MANUFACTURER: 1002 N E 116TH STREET U 1.015" x 9" x 10 GAU HINGE REINFORCEMENT DRILLED AND TAPPED FOR (4) #12-24 SREV 9 HINGE CUTOUT DETAIL 5 ON DOOR AND FRAME Q a' ,CONCf�E7E 'Q ..SL s'LjjIssenst-eelmoors 8 SILL DETAIL _ �rhh� MIAMI, FL 33161 1 AS PER BCCO NOTES REV. NO. DESMPION PRODUCT. SINGLE DOOR SYSTEM GENSTORM SERIES. P 5 1k 4950, Hickmore, St —Laurent, Quebec Canada, 1-14T 1K6 Tel: (514) 733-3562 TITLE- DETAILS AND BILL OF MATERIALS SCALE DRAWN BY: APPROVED BY: FLORIDA 24140 NONE AG JUN 24/05 DATE SHEET NO.: 5 of 6 DWG NO.: GS-10004 DATE: MAR 2005 4 1/2" 4 1/2" 10" 0.173" 0 MASONRY WIRE ANCHOR 2 1/8" " 2 8 GA 2 1 /2"-18 GA � . DSTEELEEL CAP D STEEL CAP 18 GA FLOOR �TVDIMASONRY ANCHOR PROJECTION 18 GA EMA ANCHOR WELDED TO FRAME 18" 78" RETAINING PROJECTION WELDED WIRE ANCHOR 1" CUPS TO FRAME D p D p 2 " /� 18 GA FLOOR ANCHOR 10 GA HINGE REINFORCEMENT 3 2 1/2"-18 GA STEEL CAP 2 1/2"-18 GA STEEL CAP PART No.: DC1000 & DR1000 2 1/2"-18 GA 18 GA EMA '. DSTEEL CAP ANCHOR 2 1/2"-18 GA ;� n STEEL CAP PART No.: DR1010 18 GAUGE REINFORCEMENT a i /4" 1 3/16" 1 3/16" 18 GAUGE REINFORCEMENT 4 1 /4" r -'L HOLES DRILLED AND TAPPED FOR 1" #8-32 SCREWS PART No.: FR1000 P LES DRILLED D TAPPED FOR 1 1/16"2-24 SCREWS Fl rtd�� � eoaiplyiAB PART No.: FR1100 0." riOAi► Ot�fri :� 3 5/8" TYPICAL EMA 1 3/4" -Ir / 4'4*17 11--00 3 5/8" 1 1 /2" ® `� O 4 3/8" 1 1 /2" TYPICAL FLOOR ANCHOR ANCHOR 20 GA STRAP REINFORCEMENT HOLES LLED 1 1/8" AND TAPPED FOR 18 GA BARREL #12-24 SCREWS SUPPORT 18 GA EDGE 19 7REINFORCEMENT �' 2 5/16" + 10 GA MORTISE LOCK EDGE 'r * • REINFORCEMENT HOLES DRILLED AND T AND TAPPED FOR #12-2 PART No.: DR1600 #8-32 SCREWS PART No.: DR1 KELVYN WHITFIELD, P.E. MANUFACTURER: 1002 N.E. 116TH STREET MIAMI, FL 33161 L sensk jj 1 mors 4950, Hickmore, St —Laurent, Quebec Canada, 1-14T 1K6 Tel: (514) 733-3562 FLORIDA 5 1 /4" A FOR 9/16" 'I IEW PART No.: H'R1030 1 AS PER SCCO NOTES JUN 24/05 REV. NO. DMMP110N DATE 'RODUCT: SHEET NO.: 3070 SINGLE DOOR SYSTEM 6 of 6 GENSTORM SERIES ITLE: DWG NO.: MISCELLANEOUS DETAILS GS-10004 CALE: DRAWN BY: APPROVED BY: DATE: NC I AG I I MAR 2005