HomeMy WebLinkAboutBUILDING PLANS, 0� General Notes A. CONCRETE & FOUNDATION DESIGN: 1. Ai.i. mw(,.RF:TE GRADE BEAMS AND FOOTINGS SHALL BE PSI MRNIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING - __APP-ROPRIATEACIAND_ASTM-REQUIREMENTS-MA.Y-BE_USED__ IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6, ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO.67 LESS THAN 3/4". AIR ENTRAINING+/- 1%- ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. , 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: 1. CONCRETE MASONRY UNITS (CbfU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE OF TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MIND" REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A NM41MUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS -FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN' OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, - INC.WASHINGTOND.C. THE FLORIDA BUILDING CODE 6th EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1 "X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #10X 1/2"-EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: I. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED FLAT WASHERS AND NUTS. HOME. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X -$OUT-DIAMETER-INTO-STRUCTURAL.ERAMING_(G_.42-MIN ). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED, 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM Al53. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 6th EDITION (CHAPTERS 16,20 & 23). F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP --TYPICAL 2. SIM -- SIMILAR 3. LION -- UNLESS OTHERWISE NOTED 4. CONT -- CONTINUOUS 5. VIF -- VERIFY IN FIELD G. RESPONSIBILITY: I. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST I3E ENGINEERED SO THAT NO BARRIER RE QU1xr:Mr:NTS OF THE FLORIDA B UILDING CODE 6t EDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. _4-IF PAVERSARE UNDERALLMINUM-MEMBERS THEY -SHALL - HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5. SCREENING MATERIAL SHALL BE 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. 6. PLEASE NOTE: 2x2 (typ) DIAGONAL BRACING SHALL BE DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: 9 PSF SCREEN WALLS: 31 PSF SOLID ROOF (1vIWFRS): N/A COMPONENTS AND CLADDING LOAD: N/A 150 MPH 116 MPH 1 B 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.013 SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 3001b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 10 PSF VERTICAL DOWNLOAD ON SOLID ROOF. 8. EXISTING 8"X8" THICKENED EDGE WITH 4" MONOLITHIC SLAB SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: MANSARD 10. SOLID ROOF TYPE: N/A ALUMINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2:---------------------------------------2„ x 2" x 0.044" 2 x 3:---------------------------------------2" x 3" x 0.050„ 2 x 4:---------------------------------------2" x 4" x 0.050„ 2 x 5: ----------------------------------2" x 5" x 0.050„ 3 x 3:---------------------------------------3" x 3" x 0.125" OPEN BACK SECTIONS 1 x 2: ---------------------------------------- 1" x 2" x 0.040„ 1 x 3:----------------------------------------1" x 3" x 0.045„ SNAP SECTIONS 2 x 2 SMS:----------------------------------2" x 2" x 0.045" 2 x 3 SMS:---------------------------------2" x 3" x 0.072" 2 x 4 SMS:--------------------------------- 2" x 4" x 0.045" 3 x 3 SMS:--------------------------------- 3" x 3" x 0.090" J SELF MATING (SMB) 2 x 4 SMB:---------------------- 2" x 4" x 0,044" x 0.100" 2 x 5 SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:---------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:---------------------- 2" x 8" x 0,072" x 0.224" 2 x 9 SMB:---------------------- 2" x 9" x 0,072" x 0.224" 2 x 10 SMB:------------------- 2" x 10" x 0,092" x 0.374" TUBE SECTIONS 2 x 2:---------------------------------------2" x 2" x 0.090" B JJ V' I G DIVISION ST. LUC#COUNTY B I REVIEWED FOR COMP AN REVIWAD DATE E KEPT ON ]OB PLANRMIT MU WILL BE MADE SITE OR NO INSPECTION ) \ fll�,y�0 aALL j A lei \,\C E N II oOaOp� 6 0 liS(- e � 0 -7 o �O.%i' �C.__ o OJr ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-maii-erb@fbcplans.com Webs ite-www.fbcplans.com C.O.A.-#29054 DATE: 8/16/2018 DRAWN BY: TLK I REVISION: I DATE: Ito 1 rR O 2O 3O 4 Job# 18_0802_18 PROJECT ADDRESS: RODGERS 1801 HAZELWOOD DR FT PIERCE, FL 34982 "ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES S .1" DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC ' F x N 2X2DJ / F s-4 2X2DJ % o r I - - - -- -- ---- - ---- -- - - - - -- - - - - 2X S-4 2X2(t 2'-0"--,r --- 1-0 6'�` 2X2(typ) f� - -N --- - 1X2 I 2X2(typ; 2 2X2(typ) 0 2X2(typ) 2X2(typ) 00 M N m m m m M :2 :2 . z M Cn co Go 00 0 N N N N N 2X (typ) 2X2(typ) x 00 /X2 IA�L �9 R°e 9� oCE/tJs�°°° �o ° a 4 o fro 7%C, &r' .c o�C%i2IL) - - - -_ FES OTI�(L EFQG EER3EAl c� ENGINEER OF RkORb: \ 1 X2 David W. Smith P.E. 01 ,tYP) / �- I S-3 I N I X I N LO I .b 7 I I I I ,tyP) I _ 2X5SMB / / I 2X5SMB a 4-1 I N X N _ 2X5SMB N x N x C _ 2X5SMB ' C \ \ N 1X2 .-------r------------T-------, E I I I 1 s-3 I 1 1 X2 I I I m m CO m M m N N N N N 0 X I N X N X N 2X2(typ) 2X2(typ) 2X2(typ) 0 I 1 X2 6/'_2" (tyP) S-4 THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC ( S-4 J \S-4 J2 S-4 FLORIDA LICENSE: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering 0 Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788.5314 Fax# 1-(866)824-7894 E-mail-erb@ fbcplans.cam Website-Wwr,fbcplans,com C.O.A.429054 DATE: 8/16/2018 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 lob# 1$_0802_18 PROJECT ADDRESS: RODGERS 1801 HAZELWOOD DR FT PIERCE, FL 34982 CONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 2" x _PURLINS (SEE A-1 FOR SIZE)ATTACHED TO #Mw/MIN f4l #10xl YP ------------.--�-anti m- - \Y N 9 .e 16" ALUMINUM GUSSET OPTIONAL ATE —B #12 SMS a 4 e OVA e \ �9V% r a o� \ ® o a • e1, BEAM "B" "N" "S1" "S2" "ST' "S4" 2X4 12 4 3/4" 1 j " 16' 3.7S" 2X5 12 4 3/4" 1 " 16" 4.75" 2X6 16 5 1" 1 " 19" 5.75" 2X7 20 6 1" 14" 22" 6.75" 2X8 24 7 1" 1 " 23" 7.75" 2X9 24 7 1" 1 23" 8,75" 2X10 28 8 1" 1 24" 9.75" BI EAVE NOTES: 1. "N" NUMBER OF SCREWS IN ANY DIRECTION. 2. TOTAL NUMBER OF SCREWSPER JOINT EQUALS 4 TIMES "B". 3. PLATE WIDTH SHALL BE DETERMINED FROM ANGLE OF BEAM AND MIN. SPACE REQUIRED. 4. GUSSET PLATES MAY BE INTERNAL OR EXTERNAL. 5. INTERNAL SCREWS FOR PURLIN CONNECTION MAY BE INCLUDED IN TOTAL NUMBER OF SCREWS. 6. GABLE SPLICE WILL HAVE THE SAME PATTERN. B BEAM SPLICE GUSSET DETAIL TYPICAL S'3 SCALE: NTS (2) #10X3" SMS CROSS SCREWING BRACE TO BEAM OR EAVE MEMBER (.125" BACKING PLATE USED) ROOF BRACE (1) 3/8" 0 THRU I / BOLT W/ NYLON LOCKING I / 2"x"T x.125" FLAT. NUT OR THREAD LOCKING / BAR (typ) MATERIALAPPLIED E ROOF BRACING CONNECTION DETAIL S-3 SCALE: N,T,S. Z•BRACKET 0.250" __ — 5"_OR7-L6_WIDTH.X_0,25.0" EXTRUDED GUTTER BRACKET @ EA. BEAM W/ (4) #12 X 3/4" SMS INTO'GUTTER LIP 1" x 2" x 0.045" OPEN BACK W/ (4)#14X 1-1/2" 0 BEAM 0 00 OO NOTE: 2X4 SMB BEAM ONLY REQUIRES 4" WIDTH GUTTER BRACKET W/ (2) 3/8" LAGS - (4) 3/8" LAG SCREWS @ 1-1/2" -- - — - SPACING @ EA. GUTTER BRACKET & @ 12" O.C. MAX- MIN EMBEDMENT SHALL BE 2" 2" x 2" xYs" X ALUMINUM THE HOST STRUCTURE SHALL ANGLE w/ (4) #14 x 3/4" HAVE AT LEAST A 2"X4" SMS INTO BEAM ON EA SIDE FASCIA AND ROOF TRUSS EA. LEG SYSTEM. CONTRACTOR SHALL VERIFY THIS AND IF 2"X2"X0,062" RECEIVING (4) #12 x 3/4" SMS SMALLER- CONTRACTOR CHANNEL W/ (2) #10X 3/4" INTO GUTTER EA SIDE SHALL BRING STRUCTURE UP EA SIDE TO COVER EXPOSED _ TO A 2"X4" FASCIA AND BEAM ENSURE LESS THAN A 2'-0" OVERHANG. A GUTTER BRACKET &BEAM ATTACHMENT DETAIL S-3 N.T.S. NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 x 5/8" SMS MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2.) HINGES MINIMUM, 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS, FASTEN A 1" x 2" x 0,044" TO UPRIGHT W/#12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. F TYPICAL SCREEN DOOR CONNECTION DETAIL S - 3J SCALE: NTS PURLIN UPRIGHT WEB LAPPED OVER PURLIN W/ (2) #12X3/4" SMS EACH SIDE THRU UPRIGHT & PURLIN "MEMBER ATTACHED TO rv�f�3)-�oXT�y�s�rs INTO SCREW BOSS 1"12"10,045" OPEN BACK ATTACHED TO PURLIN W/ (2) #10X1-1/2" SMS INTO SCREW BOSS 1"12"10.045" OPEN BACK ATTACHED TO 2"X2"Xo.045" EAVE RAIL MEMBER #10X1-1/2" SMS @ 24" O.0 0 NOTCH POST AS NEEDED C SLOPED OR FLAT PURLIN UPRIGHT LAP DETAIL S'J SCALE: NTS BEAM SCREWS 2" X 4" SMB 6 2" X 5 "SMB 6 2" X 6 "SMB 8 2" X 7" SMB _ 8 2" X 8" SMB 10 2" X 9" SMB 10 2" X 10" SMB 12 FOR SLOPED BEAMS, MAINTAIN ALL SCREW SPACING FROM EDGE OF BEAM 2"x 2" EAVE RAIL SECTION (UNLESS OTHERWISE SHOWN ON S-2)�_ - ATTACHED TO BEAM w/ (3) 10X 2" SMS INTO SCREW BOSS 1" X 2" OPEN BACK EAVE RAIL ATTACHED TO UPRIGHT w/(2 #10 x 1)h" SMS INTO SCREW BOSS 010 X 1 Y2" SMS 24" C/ #14X 3/4" SCREWS . (SEE TABLE ABOVE) i i i SrELF-MATING BEAM —SHALL BE NOTCHEE 1:45/4 FOR UPRIGHT 0011 9 0 li FA C u�GG -O p C E pp o ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 ZephyrhiJls, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-maiI-erb@fbcp1ans.com W ebsite-www.fbcplans.com C.O.A.429054 DATE: 8/16/2018 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 Job# 18_0802_18 PROJECT ADDRESS: 1801/HAZELWOOD DR "NOTCH OFINSIDE BEAM FT PIERCE, FL 34982 0 SLIDE OVER UPRIGHT CONTRACTOR: " (MIN) UPRIGHT K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 D UPRIGHT TO BEAMCONNECTION - ALL WIND ZONES S_? SCALE: NTS DETAILS S-3 THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT PERMISSION OF TRAC DESIGN, LLC r- Uri LUIN $1-tl- - - ILL CLIP MAY BY PLACED ON DOUBLE COMPRESSION 5° TOP OR SIDE OF DECI(W/ SLEEVES (2) 3%8"X 3'.' SLEEVE TOP OF ANWOR 4" NOMINAL SLAB CONCRETE- _ - - - MINIMUM a a. a • a' -- - c j8 EO)-MASONRY ILWELDED =230UFSICONCRE I E W/ ANCHOR (MIN 3-3/4" OPTION #1 WIRE OR EMBEDMENT) (4"SLAB ONLY) FIBERMESH 0,125" STAINLESS may° _ STEEL CABLE 2500 PSI CONCRETE W/ \I S1_ TOP OF rWELDED WIRE OR a1, 4" NOMINAL SLAB GI MINIMUM a O d 1-1/2" X 5-1/2" ALUMINUM / OPTION #2 STRAP W/ (2) 3/8 "0 X 3"-/(USE WITH FOOTING) MASONRYANCHOR (MIN 3-3/4BEDMEN13 ( 11 1 CABLE TO FOUNDATION CONNECTION DETAIL S_4, SCALE: NTS OPTION #1 (4)#10 x 1 Y2" SMS SCREW B( OPTION #2 o�ii1'po9aa,;yba u UPRIGHT\®� �, L SECONDARY ANGLE MIN �°�� o°V`C EiV 19,5" THICK (NOT [4) �� -SM RE I D R 2X3 _ ° FASTENING SECONDARY ANGLE TO COLUMN (fY EACH SIDE) (B) - CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE(TYP EACH SIDE) (SEE O A TABLE) O O (M[N) (TYP)(SEE TAB Column Size 1/4"& 3/8" 0 Concrete Screw Anchor B Min. Spa 2x3-1 4' 2x4-1 4' 1 2x5-1 4' b-3/8' 1 2x7-3 8" 1 2x8-3/8" 2 -3 8 2 2x 0 3/8' 2 le.RE FO MEMBER) PRIMARY 2" X 2" X 0.-123'-ANGLE- (2) #1.0 X 3/4" SMS FASTENING COLUMN TO PRIMARY ANGLE (TYP EACH SIDE) 1" X 2" BASE MEMBER (TYP EACH SIDE) a (1) - CONCRETE SCREW (SEE A TABLE ANCHOR INTO PRIMARY 00 6�f'i�'s7ONA L =P F S ONAC EIQGI SEA)— 3" (MIN) ANGLE AND @ 1/4" 0 CONCRETE SCREWANCHOR@ ENGINEER OF RECORD: David W. Smith P.E. 24" O.C. BETWEEN COLUMNS FLORIDA LICENSE: 53608 NOTES: C►YP EACH SIDE) Thomas L. Hanson P.E 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. FLORIDA LICENSE: 38654 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING ark R. Dunn P.E. SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT FLORIDA LICENSE: 73968 LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING Joel Falardeau P.E. WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED FLORIDA LICENSE: 70667 ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED Erik Stuart P.E. BY ENGINEER. 4.2X3W/1X2 CORNER POST SHALL REQUIRE SAME BASE FLORIDA LICENSE: 77605 CONNECTIONS AS 2X4 SHOWN IN TABLE. @)j2"x 3" OR LARGER UPRIGHT TO CONCRETE W 0 PAVER DETAILS SCALE:NTS NOTE: WHEN USING OPTION #2 % CONNECTION CABLE MUST BE L WITHIN 6" OF CORNER OR PRIMARY MEMBER, TI 1" X 2" X 1/8" ANGLE (4) #12 X 3/4" SMS T ® ® (TYP TOP AND SIDE) DIA. STAINLESS L CABLE 3/8" WELDED STAINLESS STEEL EYE BOLT (8) #14 X 2"12" OR 2"X3"_j I I 0.062" ALUMINUM INTERNAL OR Side View MEMBER EXTERNAL RECEIVING CHANNEL 1" 0 (MIN) WASHER I W/ (4) #10 X3/4" INTO INTO BENEATH NUT LBEAM OR UPRIGHT. (2) #14X 3/4" EA. LEG INTO GIRT OR PURLIN - ® e o ° (0.062" ANGLE CLIPS w/ (2) #140/4" SMS EA LEG) 5" FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W eb s ite-www. fb cplan s. co m C.O.A.429054 1/8" ALUMINUM DATE: $ 16 2018 PLATE @ 45° ANGLE W/ 1" BREAK @ 90° W/ 5/16" EYE BOLT DRAWN BY: TLK REVISION: DATE: W/ LOCK NUT & WASHER EA SID RO 1 #14X 3/4 SM RO 2 " O.C, RO 3 OPTION #3 RO 4 Job# 1$_0802_18 PROJECT ADDRESS: RODGERS 1801 HAZELWOOD DR FT PIERCE, FL 34982 UPRIGHT OR BEAM -SNAP Top View ° 3/8" 0 ADJUSTABLE EYE OR SELF MATING OR II BOLT FOR CABLE TENSION HOLLOW H OPTION #2 ° 1/8" 0 STAINLESS PURLIN OR GIRT TO BEAM OR POST DETAIL STEEL CABLE S_ A SCALE: NTS PERIMETER FRAMIN 2"X2"X 1/8" EXTRUDED ANGLE ON 45° ANGLE Side View OPTION #1 T T2 CABLE CONNECTION AT CORNER s`_4, SCALE: NTS CONTRACTOR: K & S INDUSTRIES, INC. '1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-4 THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WTHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC