Loading...
HomeMy WebLinkAboutCAR PORT PLAN TYPE 8-13-18eALUMINUM SCREEN DESIGN- Aluminum & Constructi.on Engineeriiog — - Ian TypesF: screen Room/Sun Room/Fill In �ool Screen/Cage (Non -Removable Screen - Designed to withstand actual Wind Speed) VICar Port �ONCEAIEOFASTENERS ORATTACHMENTS ❑Patio Cover IkECEiVE® ARE THE RESPONSIBILIiYpFTHE THEig PLANS AND ALL ROPOSED AK CONTRACTOR OF RECORD � ANN ❑ ,I I��dECT TO ANY RRECT-PI,II,l� °� F 1 t fiEl��� �YFIELD IN PECTORS TMA� BY *A _ r Name: Coastal Aluminum Construction, Inc. reSS: 496 S Market Avenue *Cif.y: Fort Pierce *Zi' Code:34982 *P ''one/Fax: (772)468-0288 *Email: tinman2287@att.net M M LUCIE COLTTTY BLTLDD, G DWLCu REVIEWED FOR CO I' RVIEWED B DATE I S.. V-_ 7Y11A PLANS AND.M%AT hNST BE KEPT ON JOB G.,N: i ItiSPECT`IION WILL BE MADE. r 5,se One::] Mail ❑ Pick Up ❑ E-File ❑Fed Ex* 3 No of Copies Fed_Ex option go to www.aluminumsereendesign.com and provide FedEx account #) nenfi• ❑Check ❑✓ Credit Card* Credit Card option go to www.aluminumscreendesign.com to pay by credit card) ;ring prepared by: x a� ... dd MM � _ � E �A^'>- q .x Engineer: Michael Thompson, MSc, P.E. (P.E. # 47509) 4401 Vineland Road- Suite A6 Orlando, FL 32811 Office:407-734-1470 Cell: 407-721-2292 Project Manager Paul Thomas 386-479-9504 Fax: 888-�81 Email: aluminumscreendesign(o)_vahoo.com Website: wv.aluminumscreendesign.com CA#3 vw93 .�G ALU/qp�qY+Yq P Elm.„.,.DAturninurn, & Construction Engineering E ,Ul mate Wind Speed (mph). 150 Exposed CategoryE C Risk Category 1 I Cw�+��„ ���r`sn/C��r'.���r„/Gill In• I ❑ Il�nsulated ❑Pan Roof ❑Futter ❑Fascia ❑Block Wall ❑Conventional Wall El 0 Wall Uprights X Top Plate X Kick Plate ,Foci r cree t age, : ❑ Dome ❑ Gable ❑ Mansard ❑ Shed/Slope ❑ 'utter ❑Fascia ❑Block Wall ❑ Conventional Wall Be4ms X Uprights X Purlin X Kick Plate ' card tort: ❑11 Insulated ❑Pan Roof ❑utter ❑Fascia ❑Block wall ❑Conventional Wall ❑ 4t" Wall Bums X Post X ❑ Ii l ,sulated ❑✓ Pan Roof ❑✓ utter ❑Fascia [-]Block Wall ❑Conventional Wall Z 4th Wall Be S 2 X 6 Post 3 X 3 cio Crete: i� ❑✓ Existing ❑ New: 4"Slab ❑Pier ❑Ribbon Footer X ❑ Ravers ❑6" Thickened Edge Utner: Note: In the event that there is a conflict with the design plans and general notes and design standard, the contractor shall uiilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction between the plans and the general notes and design standard. die Enginleer: Michael Thompson, MSc, P.E. (PE#47509) 4401 11 Ipneland Road Suite A6, Orlando, FL 32811 (CA#30930)-Ph 407-734-1470/Fax 407-734-1790