Loading...
HomeMy WebLinkAboutNOARECEIVED AUG 0 7 1018 ST. Lucie Gounty, Permitting i MIAMI DARE COUNTY PRODUCT CONTROL SECTION r1YIII+1T O z REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 AND CODE ADMI USTRATION DIVISION Miami, Florida 33175-2474 T (786) 315 2590 F (786) 315-2599 OF ACCEPTANCE % Building Products Corporation Orange Street hocton. OH 43812 VJL Y• s NOA is being issued under the applicable rules and regulations governing the use of construction materials. The umentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be d in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). T 1 is NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (li Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted er, the manufacttuer will incur the expense of such testing and the AHJ may immediately revoke, modify, or su pend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if t is determined by Miamm Dade County Product Control Section that this product or material fails to meet the r mrements of the applicable building code. `11#s product is approved as described herein, and has been designed to comply with the Florida Building Code in luding the High Velocity Hurricane Zone of the Florida Building Code. : Ultra HT Wind & Water Seal � High Temperature LBELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following tement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. ENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change the applicable building code negatively affecting the performance of this product. the ERMINAMN of this NOA will occur after the expiration date or if there has been a revision or change in iterials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section this NOA shall be cause for termination and removal of NOA. DVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the piration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done its entirety. PECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and be available for inspection at the job site at the request of the Building Official. NOA consists of pagesrou E. Collao COPY 1 through 3. submitted documentation was reviewed by Juan , R.A.FILE NOA, No.: 13-1VJs06 Expiration Date: 03/27/19 Approval Date: 03/27/14 Page 1 of 3 ROOFING COMPONENT APPROVAL Cate o Roofing Stub -Category: Underlayment SBS SCOPE: ,; . n This acceptance is for Ultra HT Wind and Water Seal, High Temperature roof underlayment as described in this Notice of Acdeptance, for use with approved prepared roof assemblies. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test , Product Product Dimensions Specification Description Ultra HT Wind and Water 36" x 67' rolls ASTM D 1970 45-mils thick (nominally), self adhering, Seam" High Temperature membrane composed of a white, non -slip cross - laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner. MANUFACTURING LOCATION: 1. Coshocton, OH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Rep2d Date PRI Construction Materials Technologies, MFM-039-02-01 ASTM D 1970 08/15/13 Inc. APPROVED ASSEMBLIES: Deck TY01: Wood, non -insulated Deck Description: New construction or reroof minimum 19/32" or greater plywood or wood plank. System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" head lap and.a lap mechanically fastened to 6" end deck with approved nails and tin caps 6" ,o.c. at the laps and two staggered rows IT, o.c. the field of the roll. Membrane: One or more plies of Ultra HT Wind & Water Seal'E` High Temperature underlayment with a minimum 3" side lap and 6" end lap. Place the first course of membrane parallel to the gave, rolling the -membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. roved for mechanically fastened metal roofing, asphaltic shingles, wood shakes and shingles, Surfacing: APp !, quarry slate roof assemblies. NOA No.: 13.112i06 pppMtd]ADE eoUNTY Expiration Date: 03/27/19 Approval Date: 03/27/14 Page 2 of 3 i 2. 3. I I 4. 5. 6• 7. 8. Fire Classification is not part of this acceptance. This acceptance is for prepared rooting applications. Minimum deck requirements shall be in compliance with applicable building code. Ultra HT Wind & Water Seaf' High Temperatureunderlayment shall be installed in strict compliance with applicable Building Code. Ultra HT Wind & Water Seal"` High Temperature underlayment may be used in mechanically fastened metal roofing, asphaltic shingles, wood shakes and shingles, quarry slate roof assemblies. Ultra HT Wind & Water Seal` High Temperature underlayment shall not be used as roof tile underlayment. Ultra HT Wind & Water Seal" High Temperature underlayment shall be applied to a smooth, clean, and dry surface with deck free of irrej ularities. Ultra HT Wind & Water Seal High Temperature underlayment shall not be applied over an existing roof membrane as a recover system. Ultra HT Wind & Water Sealf High Temperatureunderlayment shall not be left exposed as a temporary roof for longer than 30 days of application. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Ultra HT Wind & Water Seal` High Temperatureunderlayment may be used with any approved roof covering Notice of Acceptance listing Ultra HT Wind & Water Sealf High Temperature underlayment as a component part of an assembly in the Notice of Acceptance. If it is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 1 . Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. All protrusions or drains shall beinitially taped with a 6' piece of underlayment. The flashing.tape shall be pressed in.place and formed around the protrusions to ensure a tight fit. A second layer of Ultra HT Wind & Water Seal'" High Temperatureunderlayment shall be applied over the underlayment. 1 . All products listed herein shall have a quality assurance audit in accordance with the'Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. X . All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or Pogo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAM4[IADE COUNTY END OF THIS ACCEPTANCE NOA No.: 13-1125.06 Mw ouoE counrnr Expiration Date: 03/27/19 MPR_•M Approval Date: 03/27/14 11 Page 3 of 3