is NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
;umentation submitted has been reviewed and accepted by,Miami-Dade County RER - Product Control Section to be
;d in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
.s NOA shall not be valid after the expiration date stated below'. The Miami -Dade County Product Control Section
Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
duct or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
nner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
pend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
uirements of the applicable building code.
.s product is approved as described herein, and has been designed to comply with the Florida Building Code
luding the High Velocity Hurricane Zone of the Florida Building Code.
: ProfileVent for Metal Roofs
TG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
"Miami -Dade County Product Control Approved", unless otherwise noted herein.
EWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
applicable building code negatively affecting the performance of this product.
,RMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
serials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
his NOA shall be cause for termination and removal of NOA.
4 VERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be.done
in its entirety.
'ECTION: A copy of this entire NOA shall be, provided to the user by the manufacturer or its distributors and
be available for inspection at the job site at the request of the Building Official.
NOA renews NOA# 12-0724.03 and consists of pages 1 through 4.
submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0821.09
Expiration Date: 11/29/22
Approval Date: 11/22/17
Page 1 of 4
ING COMPONENT APPROVAL
y: Roofing
tegory: Ventilation
1: Plastic
.m Slope: 3:12.
NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Product Dimensions Test Product
Specification Description
7ent Ht. = 1" TAS 100(A) Plastic low profile attic ridge vent consisting of a
Width = 3" two layer composite consisting of a nylon -
Lengths = 20' roll polyester, for installation in shingle roof systems.
50' roll
100' roll
500' roll
TI E NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test Product
Product Dimensions Specification Description Manufacturer
He Head Screw. with Min #14 x 2" TAS 114 Corrosion resistant, hex head Generic
W ather Seal Washer screw with weather seal washer.
NUFACTURING LOCATION
Wrens, GA.
DENCE SUBMITTED
Test Agency/Identifier
itectural Testing
Name Report Date
71302.02-109-18 TAS-100(A) 09/25/07
H6999.01-106-18R0 ASTM D635 11/08/17
ASTM D 2843
NOA No.: 17-0821.09
Expiration Date: 11/29/22
Approval Date: 11/22/17
Page 2 of 4
0
1
3.
4.
.OVED APPLICATIONS:
Name: ProfileVent
i Type. A: Mechanical attachment of static ridge vent over metal roof panels and under Metal roof
ridge cap.
1. Allow a 3" opening centered in the deck at the ridge for ventilation. The slot shall
terminate approximately 12" from the rake edges.
2. Rollout ProfileVent along ridge about'/2" to 1" up -slope from edge of metal roof ridge
cap from gable to gable.
3. ProfileVent can be cut with scissors or utility knife.
4. When splicing ProfileVent make the splice at the center top of the high rib and use
caulk or sealant along the splice
5. Fasten the metal roof ridge cap according to the metal roof manufacturer's instructions;
but in no case shall it be less than a #14 x 2" corrosion resistant hex head screw with a
weather seal washer fastened at a maximum spacing of 9" o.c. along both sides of metal
roof ridge cap and through each rib of the metal roof panel.
Free Area: Refer to Manufacturer's Published Literature
Slope: 3:12
ITATIONS:
Refer to applicable Building Code required ventilation.
Ridge Vent shall comply with applicable. Building Code.
Ridge Vent shall not be installed on roof mean heights greater.than 33 feet.
All products listed .herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 17-0821.09
Expiration Date: 11/29/22
Approval. Date: 11/22/17
Page 3 of 4
DETAIL A
Various lengths
r - 9.00 TYP — . . 75 094
—►1 3.1 -, P L_-
2.75 TYP -tomes
-- .438
313
—� 75D
Detail A Detail B .
INSTALLATION DETAILS
Metal Ridge Cap
1.937
DETAIL 'A' DF-TA1L 'Q'
Metal Roof
I Polymer Ventilation
Plywood Deck Material
End View
Per Metal Roof
Manufacturers Instructions
but no more than 9" o.c. maximum
I
Isometric View
END OF THIS ACCEPTANCE
Metal Roof Fasteners
#14 x 2" Minimum Hex Head
screw w/WSW
V GI ILI Id LIUII
Material
NOA No.: 17-0821.09
Expiration Date: 11/29/22
Approval Date: 11/22/17