HomeMy WebLinkAboutPROJECT INFORMATIONG ull ING SUPPLY Fe IMANJUFACTUR Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 2 6 G 5 V rui I Florida Product Approval #11651 13 R3 Florida Building Code 2017 Per Rule-61 G20-3 Method: 1 -D Category" Roofing. Subcategory: Metal Roofing Compliance, Method: 61 G20-3.005(1)(d) NON HVHZ Product' Manufacturer: GtAf Coast Supply & ManufacuHng, LLC. 14429,SW 2nd Place, Suite G.30 - Newberry, FL 32669 0", Dl� jAXF-L S. A-i"...... Engineer Eva ' ivator: Dan Kuhn, RE. 475519 Florida Evaluation ANE ID: 10743 Validator: Loclk,e Soi&yal(an. PE. 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaivatzo,n Rqport pages'l - 5' FL# 11651.13 R3 - OCTOBER 5, 2017 V.. OGEN 's O No. 75519 -ATE OF OR I 6/01VA L Stp%%" Compliance Statement:' Product Description: Panel Material/Standards: Panel Dimension(s): Panel Fastener: Substrate Description: Design Uplift Pressures: 11651.13 R3 m OCTOBER 5, 2017 Ix Gulft9 e drG "� irrC fi�"`C k1 �Pt`j SUPPLY & M'ANUFACTURING The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel with fasteners in the panel flat over minimum 15/k" plywood decking. Non Structural application. Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building. Code 2017 Section" 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507A3. Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/a" Major"Rib #9-15xl .5" with sealing washing in the flat of the panel or approved equal, 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building. Code 2017. Table ",A" I llaxirnurriF%tal Upir C Desrgr i�resstr e 94 5,ps ;� 1`-3 psfi ' Fastener Pattern 12"-12" 9.5"-2"-9.5" r Fas�erier Pattern Spat►n�g � r � v ��, � < 1 �z Q C 4 16"�-O.0 Design Pressure includes a Safety Factor = 2.0. N t x r SiiPPI't &_P,AANUr'�aC,U{;t1�3C Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural.wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: o UL 580-06 - Test for Uplift Resistance of Roof Assemblies ® UL 1897-12. - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897798 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0053T-05 & 117-0331 T-0$ 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) 0 Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. . (duality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3) for manufacturing under a quality assurance program audited_ .by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1 _ Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FLY 11651.13 R3 o OCTOBER 5, 2011 "tea ✓ . � Design Procedure: FL# 11651.13 R3 OCTOBER 5, 2017 NhW $ F J- ip For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the -load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded..This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. d law ® eu a SUPPLY &.. MANUFACTURING E GINEER LOAD TABLE: 26 Ga. SVCrimp Roof Panel over 15132". Plywood B?Idtngs Flauing a Roof1lean Helgiti<0' 0" Roof Slope 2"Y12r"2'11"! Gailer,hfip Roof,/lnd �pe�tls2Q #F_ 1,a Jmpk1�,,t±Xposur"erC �Rrs4� Category II, Enclosed Bulldil7g� based on Flot�da Bu►fding Code 2�}`1-/ _ .. ,,,, �.::. . ~ ` 3.• 4 ~ . - 120 .130 140 150 160 170 .180 LIND FASTENER SUBSTRATE (MIN. (MIN. 15132") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER (PEED ti Penetrati Penetration) SPACING, SPACING SPACING SPACING SPACING SPACING SPACING �Ot�E 4w{ 1 � #� `�X'C 5" ��, F'Iywoad � �k.. ?16 TYPE" r 16" TYPE1i P '16" 3G" TYPI� 1 ''16" TYPE � 3 16"`TYPE i ' 16"TYPE 1 �16" TYPE 1= . ZONE 2 #9-15x1.5" Plywood 16" TYPE T TYPE 1 16- TYPE 1 1V TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 QN 3 #9 15X1 `S'Y Plywacrd 16 TY!'E 1 a1 F TYPE 1 16" YPE 1 16 ,TYPE 1 16" TYPE 1 'i 1 TYPE 2 76" TYPE'42 1. PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE. 80, 24"COVERAGE. 2: PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN. 1/4" PENETRATION, 3. MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0 PSi @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4. PLYWOOD DECKING: MIN.'S/3z" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5. ROOF SLOPE: ON ROOF SLOPES LESS THAN 3.12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6. 1 LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING C DE 2017. ZONE 2 HIP ROOF ,'�t ZONE 3-,.j �,`, - _• 1, w RIDGE / ZONE 1 1 Note: Dimension (a) is defined as 10% of the minimum width of the building or - (a 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be less than either 4% of the minimum width of the building or 3 feet, N TYPE 1 FASTENER PATTERN EAVE ZONE 2 GABLE ROOF 'rl -------- --------I-- -- .ra 1 i ' I /—RIDGE -----\\-�---r— — — — — — — — — — — a —_------------------=- J.a t ZONE 1 s -ZONE3 `—EAVE FL# 11651.13 R3 o OCTOBER 5, 2017 (1) #9-15 x 1-1/2" HWH w/Sealing Washer ��---12" 12'1-� At Panel Lap �s . TYPE 2 FASTENER PATTERN (1) #9-15 x 1-1/2" HWH w/Sealing Washer vt ff ..... Gul & MANUFACTURING :TYPE 1 FASTENER PATTERN F (1) #9-15 x 14/211 HWH W/Sealing Washer 12" 1211 At Panel Lap TYPE 2 FASTENER PATTERN -(1) #9-15 x 1-1 /2" HWH W/Sealing Washer 2" -- 9.5" 905112" 1 a� N1EL S.�. �'\GE/V 4 m * No, 75519 STATE O Al •G 11651.13 R3 o OCTOBER 5, 2017 IN