Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL STRUCTURAL WALL1@018 Florida Building Cade Online W t_ � �� f� :� ��•�� ''.7 1��...���'1�,..�}� �tit�l, kIS lfeme. Lag In L User RegtstraUon I HatToplcs i Submitsurcharge I 'Stats&Fads I Publications I FBC Staff i acfs Site Map Unkr.I Seardt I bisP'roduct Approval3USER: Pubtic User - Product Aapmwl prenu > Product arAopllotron Searetra Appncatran Lrst> Appllotton Oatalr IS "" "° D BY F( # FL6702-115 {� p ..."td APPficatlon Type. Revisfbn 14 UC U©WlN P�1 Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Carolina Carports,Inc Address/Phone/Email 187 Cardinal Ridge Trall Dobson, NC 27017 (336) 367-6400 FLvalidation@yahoo.com Authorized Signature robert cope jason.c6caroiinacarports.com Technical -Representative Address/Phone/Emal( Quality Assurance Representative Address/Phone/Emall Category Structural_Components Subcategory SWctural Wall Compliance Method Evaluation Report,from a Florida Registered Architect or a Licensed Florida Professional Engineer. Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Terrence E. Wolfe. the Evaluation Report .Florida License PE-44923 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 03/14/2027 Validated By Brian Saks, P.E.' v Validation Checklist = Hardcopy. Received Certificate of Independence FL6702 R5 COI Letter of Certification.ndf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified -By Sections from the Code 1709.2 Product Approval Method Method 2 Option B lg.orglpr/pi app_dti.aspx7param=wGEVXQwt.DglploPjbBuS3h8swa5aoOlFgegXWnt3stYa/o3d' 1/2 Date Submitted -Date Validated Date Pending FBC Approval Date Apprave d' Summary of Prnduetc Flarida Building Code Online 08/15/2017 08/17/2017- 06/21/2017 10/10/2017 , FL # Model; Number ar Name Description 6702.1 AG Panel .. 26 Ga. AG.Wall Panel over open framing . Limits of Use Installation, instructions Approved far:use in HVHZ: No. FL6707 R5 II 26 Ga. AG Wall Panel-Secured.pd� - Approved for use outside, HVHZ: Yes Verified By: Terrence'E. Wolfe, PE. 44923 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +57.3 psf/-62.5 psf - Evaluation Reports Other: See Evaluation Report for various design pressures. FL6702 R5 AE 26 Ga. AG Wall Panel - Secured,pa Install per manufacturer's details. Not for use in HVHZ Zones.... Created by Independent Third Party: Yes 6702.2 A.G Panel 29-Ga. AG Wall Panel. over open framing Limits of: Use Installation Instructions .Approved'for.use in HVHZ: No FL6702. R5 II 29 Ga. AG Structural Wall Panel NON HVHZ -. . Sec ured.adf Approved for use, outside. HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 . . Design Pressure: +41.6 PSF/-57.3 PSF Created by Independent -Third Party: Yes Other: See Evaluation Report foe various design pressures. Evaluation Reports Install per manufacturer's details: Not for use in HVHZ Zones... FL6702 R5 AE 29 Ga. AG Structural Wall Panel NON HVHZ - Secured& Created by Independent Third Party: Yes 6702.3 Dutch Lap Panel . 26 Ga. Dutch Lap Wall Panel over open framing Limits of Use Installation Instructions Approved for use in HVHZ: No FL6702 RS II Dutch Lap Metal Wall Panel NON HVHZ - Appiroved for use outside HVHZ: Yes 3eCUred.pdf Impact -Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +24.4 psf/-26.0 psf Created by Independent Third Party: Yes Others See Evaluation Report for various design pressures. Evaluation Reports , Install per manufacturer's details. Not for use in HVHZ zones.. FL6702 'R5 AE Dutch Lao Metal Wail Panel NON HVHZ - secured,pd j - = Created by Independent Third Party: Yes 6702.4 . Dutch Lap Panel 29 Ga. Dutch Lap Wall Panel over open framing Limits of Use d Approved for use in HVHZ: No + Installation Instruction's FL6702 R5 it Dutch Lap Metal Wail Panel non hvhz Approved for use outside HVHZ: Yes secured.OdF Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923, ' Design Pressure: +39.1 psf/-35.5 psf Created by Independent Third Party: Yes Other: See Evaluation Report for various design pressures: Evaluation Reports Install per manufacturer's details. Not for use in HVHZ zones. FL6702 R5 AE Dutch Lap Metal Wall Panel non hvhz secured&df Created by Independent Third Party: Yes Cantos! Os :: 260C Blair Stono Road- Tallahassee FL 32399 Phone: 850-487-1R24 The State of Florida is an AA/EEO employee ggpyAght 2007-2013 State of Florida.:: Privacy Statement :cAccesslbllity Statement n Refund Statement Under Florida law, email addresses are public records. If you do notwant your e-mall address released In msponse to a public-mcords request do not send cicdfonla mall to this enUty. Instead, contact the office by phone or by traditional mall. if you have any questions, please contact 550.487.1395. `Pursuant to Section 45S.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455,.F.5, must provide the Department with an email address If they. have one. The'emalls provided may be used for ofUdal communication With the licensee. However emall addresses am public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455, F.S.,. please dick here . ProductAPproval Acceptsm - Credit Card Sate 212 I Force Engineering &Testing Inc.' 195301 Dmc' Humhl.# 77338' NOW Evaluation Report . CAROL'INA CARPORTS, INC. 26 Ga.-AG Wall Pdnei over open. framing Florida: Product Approval # 6702.1 RS Florida Building Code 2017 Per Rule 61G20-3 Method:2—B. Category: Structural Components' suiicategory: Structural Wall Compliance Method: 61G20-3.005(Z)(b) NON HVHZ Product Manufacturer: CdrOna'Carports; Inc. 187 Cardinal Ridge Trail Dobson, NC 27017 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID:1920 Validator: Brian Ja&s P.E. #70159 Contents: Evaluation Report Pages 1— 4 C E. F, NO.40 d• STATE OF 'ion AL 'D A `V sm.oram�. ++0�Ess • ORI .GS��� acd FL# 6702.1 R5 Augmt.16, 2017 Force Engineering & Testing Inc. 19530 Rambleaood Drive . Humbio,'fX 77338' . Compliance Statement: The product as described in this report has demonstrated compliance with the. Florida Building Code 2017, Sections 1769Z: = Product Description: AG Wall Panel; 26 Ga. Steel, 36" Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, panelmaterial shall comply with Florida Building Code. 2017 Section 1405.2. Yield Strength:, Min. 80.0 ksi Panel Dimension(s): Thickness: 0.0185" min. order thickness Width: ' 36" maximtim coverage Rib.Height: '/." major, rib 'at 9" O.C. Panel Rollformen MRS Metal Roilforming Systems Panel Fastener: #1Z-14 x'/.".HWH SD#3 with 5/8" (16mnt) diameter sealing washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017. Substrate Description:, Minimum' 14 Ga. (Grade 50) Steel tube framing or Minimum 18 Ga: (Grade 50) , Steel hat channel purrins/girts. See Table A for steel gauge. Framing must be • designed in accordance W% Florida Building Code 2017. Allowable Design Pressures:. Table'"A" . Maximum Design Pressure : =59.9 Psr. •83.3 psf _ +46.9 psf. +573 psF Panel Fastener Pattern: 2-1.2-1 Panel Span: .. 51-W O.C. 4'-0" O.C. 4'-0". O.C... 5'-W O.C. 4'-0" O.C. Substrate: : 'Min. Ga. Steel Framing Min: IS Ga. Steel -Framing Min.14 Ga. Steel. Framing Min.18 Ga. Steel Framing Min.18 Ga. Steel Framing ­siirFe wemnuae5aaaieryracrar=Au. f... �+ .. q No. 940* 1 STATE OF •1. FL# 6702.1 R5 August 16, 201..7 Force Engineering & Te'sdng Inc. 1953022mblcwoodDrive Humbie,TS 77338 Code Compliances The product described herein has demonstrated ca'mpliance with The Florida Building Code 2017, Section 1709.2. . Evaluation Report Scope; The product evaluation is limited, to compliance with the structural wind load: requirements ofthe' Florida Building Code 2017, as'relates.to Rule 61G20-3, Performance Standards The product described herein has demonstrated compliance with: ■ - ASTM E 1592-05(2012) Test method for structural performance of sheet metal roof and siding systems by unifarm static air pressure difference Reference Data: 1. ASTM E.1592-05 Test' Force Engineering & Testing,, Inc. (FBC Organization # TST 5328)' Report No. 183=0063T 16A-E 2, Certificate of independence By Terrence E. Wolfe, P.E."(No.44923) @ Force Engineering & Testing,.lnc. (FBC Organization # ANE ID:1920) TestStandard Equivalency: The ASTM E 1592-05 test standard is equivalent to the ASTM E 1592-OS (2012) test standard, " Quality Assurance Entity: The'manufacturer has established compliance of wall paneiproducts in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for. . rhariufacturing under a quality: assurance program audited by;an approved.. - quality assurance entity.. Installation: Instal{ per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Sheardiaphragm values are outside the -scope ofthis.report: • ,��,ii n illti��I� • 0 - C E, - �`�♦` J. 0, CE ♦ N Q� .1 a . ... STATEO • F' ; a • RI se.arkds •.�?`�. /Yrlt d HAL � t tt tttl FL# 6702.1 RS I August 16, 201'7 I Foscc E,. gmecring & Testing Inc. . _ .. : 19530 Ramblcwood Drive.. .. 116mblc•TX 77336 Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener . attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with, Florida Building code 2017 Chapter 22 for steel,, and Chapter 16 for structural loading. 5. �Vk•C E, �. No.449� � Y-V STATE OF :Ct 0 Ri sm•cntem �i Fs • CaA FL# 6702.1 R5 August 16, 2017