Loading...
HomeMy WebLinkAboutREVISION TYPICAL SCREEN ENCLOSURE DETAILSR FT, I T7I a; 9acK I I cox-I�fy U I 3 1' RE�va 3pq /tq REVIEWED FOR CODE COMPLIANCE ST. LUCI��E��+COUNTY TlzvCTuRJ�i~ Guti1'r r� 1 — � 1 I 2n3 I j xx3 00 to 00 � �N N N ibo N �l 1 +10 0� x 5 2x3 r I 10 IDO YEON IPCIM, P_E. < PLA. LAC_ NUMBER 4949, CA_ # 20887 oO KIM a L_LC P.O_ 13 X 10 39 TAMPA, L 679 (813) 8 966 ?<<4'IT � �ti1y EAVE RAIL "I TOTAL) - 012 x ' I' x 2' O.B. '_SAO N C - MIN. PATIO SECTION PLATE EDGE DISTANCE & C-C FASTENER SPACING) A 00 6'x5'x0.050' —6063-T6-ALLOY--PL-ATE- G (ONE SIDE) OR STRONGER a 1 K-BRACE — 3' x 3' x 0.050' MIN. 6063-T6:ALLOY PLATE OR STRONGER (ONE SIDE) WITH 2x3z0.070 CHAIR RAIL (3) - #12 x %' S.M.S, EACH `SIDE AS SHOWN (%' MIN. PLATE EDGE DISTANCE K-BRACE & C-C FASTENER SPACING V K-BRACE 1 CORNER POST 3' x 2' x 0.050' MIN.,;6063-T6 ALLOY PLATE OR STRONGER (ONE SIDE) �1 (3) - #12 x %'i S.MS, K-BRACE EACH SIDE AS SHOWN (1/z' MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING), (5) #I2x3/4' tx2 O.B. ATTACHED TO BEAM W/_._' (2)-#10X2" S.M.S. INTO SCREW BOSS ✓; (1)-1/4"xl - S.S._THRU-BOLT W/ Y4" NUT AND: -.WASHER ® EACH SIDE=.OF BEAM #12x2" S.WS� 0 24" O.C. Ix2 O.B.;TO SUPER GUTTER (4 412x3/4" S.M.S. BEAM OR SLOPED) -2246- ANGLE, EACH FOR 2x8 SMB OR LAR I' x 2' taLE PLATE If \\ OTHERWISE %' 0 CONCRETE ANCHOR (2 PLACES) IN LIEU OF TYP. Y' 0 CONCRETE SCREWS FOR CORNER COLUMN LATERAL" ' BRACING CONNECTION DETAILS 0 �': SPACE SCREWS EQUALLY (TYP.) COLUMN As �LCF 0, N GIRT (CHAIR RAIL) -I !/ A.S. . lx5x%' ANGLE 6' LONG (TYP. 8 EACH BEAM) (2) Y4'Ox3' LG. Q EACH ANGLE NOTE, PRIMARY SCREEN ENCLOSURE_ ATTACHED TO HOST STRUCTURE CON CONVENTIONAL TRUSS/RAFTER FRAM FACIA TO BE 2x6 (MIN.) S.P.F. OVERHANG NO TO EXCEED 30' UNLE OR WESTER RED CEDAR NOTED ON PLAN DWG. STRUCTURAL GRADE 2 MIN. (1) )%'0X2' LG. LAG SCREW a 24' O.C. ENTIRE LENGTH OF GUTTER SECURE FASCIA TO EACH RAFTER TAIL x SEE ELEVATIONS FdR 'K' BRACE SIZE lxlx%" BY 2' LONG - ANGLE, EACH SIDE (TYP.) (4) #14A" S.M.S., 2 SCREWS EACH LEG (TYP.) HOLLOW POST — BEAM STITCHING SCREWS (SEE TABLE) 2 24' O.C. ' SPLICE PLATE (EACH SIDE OF BEAM) A //5052-H32 ALLOY OR EQUAL, 1/8' THICKNESS oJP�' E kl / VNE B&' ZOZPy ) .s14". SCR lC MANSARD BEAM )NNECTION DETI :-i_ j —@ DO KI M & ASSOCIATES, LLD CONSULTING STRUCTURAL ENGINEERS ;4 Tampa, FL 33679 #14x:$' SCREWS Tel: (813)374-0321 (x) (xx) (xxx) (xxxx) LINE LINE SCREWS PLATE " BEAM 'j Rev./DateDEISCFIPtIOf .�51� A' 'B'B,'C' TOTAL WIDTH P� 2x4 3 2 24 12' 0 7n7 2015 ISSUED 2x5 3 3 32 14- 2x6 4 3 40 14' , 0 2x7 5 4 56 16'� 0 r 16! f 2x9 5 6 72 18y r/A, 2x9(HW) 6 7 88 ?F�8' :; IL 2xIO 7 7 _ iC 18' (3) #124j' S.M.S., EACH LEG AND (6) #12x>" S.M.S. CHANNEL TO BEAM (9) SCREW TOTAL (SEE PLAN) BRAKE -FORMED RECIEVING (MIN. 0.062" MATERIAL THIC4 1" x 2 1/8" x 1" x 3" LG. A' MIN. (4) #104" LONG) (TYP. ALTERNATIVE) S.M.S. INTO SCREW BOSSES TYP � ALTERNATWE) S.M.B. POST IS SHALL BE ING OF CHAIR RAIL / GIRT TO POST WITH THERWISE ISE CONNECTION DETAIL i'. 2x PURLIN W/ (1) Y4'OX4' LONG PAN HEAD LAG SCREWS (2) RAIL "I S.M.S. THNU. 2x3 BEFORE ATTACHING SUPER GUTTER EAVE CREW 8055ES USE #I0x1Yz' S.M.S. �0,724" O.C. 2-�- TO CONNECT TO•ilxO.B. TO 2x3. r (4) #12x3/4" (EIf7 1 R) (1) Y4'0x2' LG. LAG SCREWS (TYP. a EACH BEAN) (1) #12x2' S.M.S a 12' O.a S.M.S. EACH LEG. a�, (MAX) BETWEEN BEAMS SIs THICK CONTINUOUS 5' or 7' SUPER GUTTER ANGLE MIN. 0A90' THICK RA /, 1x2 O.B. FASTENED TO COLUMN/POST W/(2) #10x%" S.A1.S./INTO SCREW BOSSES ,.,' � (EACH END, TYP.) SECURE FASCIA TO EACH RAFTER W/ (1) Y4'Ox4' LONG PAN HEAD L• BEFORE ATTACHING SUPER GUTTE BEAM TO SUPER GUTTER s CONNECTION DETAIL #10x3/4" S.M.S. Y.' CONTINUOUS BEAD OF CONSTRUCTION ® 2' O.C. ADHESIVE PURUN FASTENED TO COLUMN/P WITH (4) #12xl" S.M.S. (EACH I USING 78" THICK FLAT BAR BEM TO FIT (6063-T6 ALLOY) COLUMN/POST , SIDEWALL POST / COLUMN TO PURL -IN CONNECTION DETAIL MIN. (4) #10x3- LONG S.M.S. INTO SCREW BOSSES (TYP. ALTERNATIVE) BEAM STITCHING ® 24" O.C. - (TYP. TOP AND BOTIOM OF SMB SEE TABLE FOR SIZES) PURLIN TO ROOF BEAM CONNECTION DETAIL W U LU 0 Z) .1x14" BY 3' LONG V ANGLE, EACH SIDE (TYP.) O (3) #12xi¢" S.M.S., EACH LEG (6) TOTAL (TYP.) z. 2x3xO.045 EAVERAIL ATTACHED TO -. BEAMS WITH (3)-#10x2" S.M.S. _ - ._.- -- - `�' ��, L)^ INTO SCREW BOSS.i - f- Li 25x.125 ANGLE-2" WIDE�WTTH - - (2)-#14xl" INTO BEAM;& (2)-#14xl' m �' INTO UPRIGHT. f o USE #10z1)2" S.M.S. ® 24" O.C. TO CONNECT TO 1x2 O.B. TO 23. '7 (9)'#12x% S.M.S. EACH SIDE U W 4: W o_ 0 (ci a wo Z c) 451, W (n 'all _I W DRAWN BY: DYK CHECKED BY: DYK S.M.B. BEAM SCALE: AS SHOWN -MAY BE SLOPED OR FLAT (SEE PLAN FOR SIZE) DATE: 8/11106 6 OF{ BEAM (TYP.) OR 321' MIN., 3 W MAX. C-C (6) !#12x%' S.M.S. EACH SIDE SPACING OF FASTENERS (TYP.) OFf'BEAM FOR 2x5 COLUMN TO 2x5 BEAM S�' MIN. BEAM EDGE ttll DISTANCE (TYP.) COLUMN/POST =MAIN POST / COLUMN TO ROOF BEAM' -CONNECTION DETAIL` DO YEON KIM, P.E. FLA. REG. NUMBER 49497 1 7 DO OCIATES, LLC 768871039 VAS, 33679 1 .11.1 pL 1 Drawing No. - 060811 SHEET 1 OF 3 3' MIN,./(TYP.) DEWALL SEE PLAN FOR SIZE .'i 1x2 O.B. FASTENED TO CORNE SECTION WITH $140)k" S.M.S.( 24" O.C. 2x2x1§' ANGLE 2' LONG (EACH W/(2) ({1;4xY4" S.M.S. TO POS & 3/8'0:jH.D. GALV. EXP. BOL W/ 2 1/2" MIN. EMBEDMENT F S.M.S. WITH MIN,Aj-- r AA EDGE DISTANCE, PVT - PURUN SUPPORT COLUMN/POST_ .: _'->-"- --•^. Jfi" ANGLE, EACH SIDE (TYP.) I.G.ANGLE S.M.S. �S" ` ��i, CONCRETE ANCHOR BEAM . _; _ 4Y#tW �9 S�+� D� - - (EACH SIDE) •_�_ STRUCTURAL CONCRETE (TYP.. STR EE NOTE 10) r,•:-.--_.;�::�_�,�� "0 CONCRETE ANCHOR - W/2%" EMBEDMENT INTO -^- 1'x2" O.B. SOLE PLATE �•~�. - -- STRUCTURAL CONCRETE _ 2"x PURUPP",. •'u - .(EACH -SIDE)-- — -- -- -�-- - - - - - --- — -- - - -- - --- - - .d• `• '•-•' '° •• •, '• v v i f'� ,j7 BEAM MAY 2x2XX ANGLE CUP, CUT AT Ix3 O.B. FASTENED TO CORNER A 45' (+/-) ANGLE, AND SECTION WITH #104" S.M.S. W/ ATTACHED TO THE SCREEN ROOFpIA. WASHER 018" O.C. CRETE ETAIL CONCRETE Y 9, COLUMN/POST 1x2 O.B. SOLE �— EDGE OF CONCRETE-_ I' N (TYP:)- _ � ` PLAN VIEW )6" ANGLE, EACH SIDE (TYP.) %"0 CONCRETE ANCHOR - W/2%' EMBEDMENT INTO STRUCTURAL CONCRETE (TYP., SEE NOTE 10) +. R 1%2" O.B. SOLE PLATE fI ..4Z • • • , N L .a •. , ..4. . . a w 3" MIN. (TYP.) Y'0 2Y" CONCRETE x yW� 4 E U U SCREW ANCHOR 0 24" O.C. AND 9" FROP4-_POST (TYP.) v � C3 '3'.� • •• F U ,\= 9• COLUMN/POST 1.. 1.2 O.B. SOLE PLATEN`' -®-- ® f P t EDGE OF CONCRETE I' (TYP.) , 1 N PLAN VIEW CONNECTIONZETAIL _1_ - :� !- BE FLAT �i n■r BEAM WITH ONE (1)'Y'0 THRU- BOLT WITH FENOEAtW SHFR._ �P•) _n■ _ _ _ _ _ -- - - - - -ATTACHED-TO-SEAM7.OR-EAVE-RAIL-- DIAGONAL BRACING NOT I OO SHALL BE ATTACHED TO RO0%PURUNS. 5 1 2x2x0.093 BRACE' (SEE PLAN). {f --• PLAN - TYPICAL DIAGONAL ROOF -BRACE CONNECTION FOUNDATION/SLAB DETAIL i COLUMN 21¢" MAX. THICK BRICK PAVERS SET IN MORTAR ON TOP OF FOOTER • O.B. SOLE PLATE Z 0 N 2x5xW ANGLE (2' LONG) W/ (2)-#14 TFKS TNTn TIIP nF P..O cA\IE-RAIL-ANTI-(2a- #14 TEKS INTO THE FRONT OF THE CORNER POST 1x2 O.B. TOP FRAME CORNER POST ELEVATION VIEW CORNER POST / COLUMN UPRIGHT DETAIL DO KI M & ASSOCIATES, LLC STRUCTURAL ENGINEERS PO Box 10039 mpe; - - Tel: (813) 374-0321 II7127 2015I ISSUED 2500 PSI MIN. CONCRETE STRENGTH :° APPROXIMATE'... I I I I 11=11 ° .11M _ J 1�1 °a II COMPACTED OR _ Q d ° PINS, UNDISTURBED SOIL/SAND — w 1 (1)-#5 REBAR, CONTINUOUS =III III1 3" MIN. CONC. COVER, 36" MIN. — LLI I H I =11 M I I� 11 I� LAP SPLICE I DTI- I I_I 1 I� � o 12" MIN." (D J o U U Z w MIN. CONTINUOUS PERIMETER FOOTING w (4) #12A4 2"x PURUN BEAM MAY BE FLAT OR SLOPES R) #IOXA YP. EACH RYP. EACH N C Z W IX o U ` \ALTERNATE •0- W � U (n UJ (1) WW 2xlxYa" ANGLE U BRACE DRAWN BY: DYK 2"xl "x1I3" ANGLE (BRACE) W/ CHECKED BY: DYK SCALE: AS SHOWN (4) #120/4' S.M.S. 0 EACH MEMBER INTERSECTION DATE: 8/11 /06 ' 2x2xVa" ANGLE 2" LONG ON UNDERSIDEW/(4) #12x% S.M.S. �- EACH LEG (BEAM & BRACE) PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 DO YEON KIM, P.E. BRACE FLA. REG. NUMBER 49497 PLAN) ALTERNATE (2) DO CIATES,LLC 2A BRACE 887 VA 0039 33679 �)'f1YR Drawing No. - 060811 SHEET 2 OF 3 General Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318, 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005-T53 Alloy, 6005-T5 Alloy, for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #10x3/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)410x2" per connection unless shown otherwise. 8. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 s/ '/2" #12 i 0.219 3/8" 9/16" #14 (1/4") 1 0.250 1h" 5/8 ` 9. Structure has been designed to meet the 6" Edition FBC (2017 FBC). Project is sited where the ultimate design wind speed, V-«, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure B. Design pressures are from Table 2002.4, 2017 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO). 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. 11. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.17.1.11. if enclosing a pool. DO KIM & ASSOCIATES, LLC __CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa; FL�3679 Tel: (813) 374-0321 1 JDate Description /. ISSUED J H W L) p C W U t=n O z U W z °)) w (I) c Z W O U CL - Z (�j U w a U ❑ DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 8/11106 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DObJ26887 CIATES, LLC 0039pa, FL 33679 11,00 Drawing No. - 060811 SHEET 3 OF 3