HomeMy WebLinkAboutRESIDENTAIL HEAT LOSS AND GAIN CALCULATIONPage 1 Residential Heat Loss and Heat Gain Calculation 7113/2016
In accordance with ACCA Manual J
Report Prepared By:
.
SCANNED
Central Air Systems Inc.
RECEIVED
y
For: Pumnan
AUG 16 �G�� . WCeCcan
6270 Beach Blanket.Cir
Fort pierce
, fl
ST. Lucie County, Permlttina
Design Conditions: Fort Pierce
Indoor:
Outdoor:
Summer temperature:
70
Summer temperature: 90
Winter temperature:
70
Winter temperature: 42
Relative humidity:
55
Summer grains of moisture: 127
Daily temperature range.*Medium
Building Component
Sensible
Latent Total Total
Gain
Gain Heat Gain Heat Loss
(6Ttll b)
(BTUN) (BTUH) (18TUH)
Duct
929
0 929 0
Floors
1,119
0 1,119 1,989
Walls
1,663
0 1,663 1,973
Ceilings
2,579
0 2,579 1,641
People
1,500
1,150 2,650 0
Fireplaces
0
0 0 0
Oise
1,200
0 1,200 0
indoors
7,317
0 7,317 3,855
oors
529
0 529 6_28
31assdoors
1,_368
_
0 1,368 964
$kyiights
0
_
0 0 0
infiltration
1,302
21697 3,999 4,026
hole House
19,606
3,847 23,353 16,076
(2 tons )
FILE Copy
VAC -Cale Residential 4.0
by HVAC Computer Systems Ltd. 888 736-1101
Load cakvtat M as esthnate; arty, =ftmi toads may vM dtto to —1hw end ccn bvaon dlFetmwz;