Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCANNED t. Lucb, Gourd EXTERIOR RESEARCH & DESIGN, I.I.C. Certifrcote of Authorization #9503 TRINIY I ERD 353 MRIMN STREET, UNIT813 OXFORD, Cr 06478 EVALUATION REPORT R CE IV E ® ` . (203) 262-9245 Soprerna, Inc. Evaluation Report S1N10.06.094M 1640 rue Haggerty A U G 16 2018 F12569-R13 Drummondville, QuL&bec J2C 5P8 Canada Date of Issuance: 06/15/2009 Sl`. Lucie County, Permitting (819) 478-2400 Revision 11:10106/2017 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted'has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments UWEUNG: labeling shall be in_accordance with the requirements the Accredited Quality Assurance Agency noted CONTINUED CGWUANM This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named, client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinkVI ERD requires a complete review of this Evaluation Report relative to updated Code requiremeriftwith each Code Cycle. ADVOMSEME n: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. iNWEcnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the iob site at the request of the Building Official. Evaluation Report consists of pages 1 through 8. pared by: Jac' 3!- t r--'�•y j,,00.5 tGF.d7F3 's' vert J.M. Nieminen• P.E. •-t: �Q ?� 7lmfaatmseOlariig�sautha¢edbyxobert daRegistrabonNa391W,FloridaMANW83 iya axa4 ;atiWkftftW RL0010300M7.iiftclmnasemasan rQhrnnia�P - dMhMie1l11�d�Nnd�t IfeW7tOA1 � iraa TrinitylERD does not have, nor does it intend to acquire or will It acquire, a financial Interest in any company manufacturing or distributing products it evatuaws. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. Robert Nieminen, P.E. does' not have, nor will acquire, a financial interest in any other entity involved In the approval process of the product This is a building code evaluation. Neither TrinttylERD nor Robert Nieminen, P.E. are, In any way, the Wgner of Record for any project on which this Evaluation Report; or previous versions thereof. is/was used for penrdtfing or design guidance unless retained specifically for that mirvose. COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underfayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6* Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.2 Wind Uplift UL 1897 2012 1507." T1507-L1,1507Z9.2 Physical Properties ASTM D1970 2015 1SO733 Physical Properties FRSA/TRI April 2M2 2012 FRSA/TRI April 2022 (04-12) Physical Properties ASTM D6163 2W8 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) ASTM D1970 / TAS 110 296805.04-2 OS/14/2004 ERD CM6049) Physical Properties 2757.02AS 02103f2WS ERD (TST6049) ASrM D1974 / TAS 110 2974.0105-2 05/17/2005 ERD (TST6049) Wind Resistance 277807.05 07/15/2005 ERD (TST6049) Wind Resistance 2779.1L05-R1 0411BA007 ERD (TST6049) TAS 203 / TAS 110 S7120AL07--2 11/02/2007 ERD (iSTW49) ASTM D1970 / TAS 210 S13190.0209-R1 04/01/2010 ER6 (TST6049) ASTM D1970/TAS 110 S3137Q0310.1 Rl 04/07/2110 ERD(TST6049) Physical Properties /Tensile Adhesion 511150A)SI R1 09/09/2010 ERD (TST6049) Physical Properties /Tensile Adhesion S11150.05.09-R2 10/0SAM0 ERD (TST6049) ASrM D1970 S37210ALU 11/09/2013L ERD (7S'r6049) ASTM D1970 S40540A2.13-1 02/19/2013 ERD(•TSWAX9) Physical Properties/ Tensile Adhesion S43530.0214-1 02/21/2014 ERD(TSM049) Physical Properties /Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD (TWM9) Accelerated Weathering SOPC-SCO52OL14 04/17/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.0517-R1 06/07/2017 M-D (CER1592) HVHZ Compliance 15-05O804 09/24/2015 ICC ES(EVL2396) 2015IBC Compliance ESR 1524 03/01/2017 PRI (TST5878) Physical Properties SOP-064-02-01 12/03/2013 Sopnema, Inc. (PDM3511) Equivalency Declaration SA SMOaM PLY40 06/29/2015 UL, LLC (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 4. PRODUCT DESCRIPTION: 4.1 LasUftn'd TU HT is a self -adhering, non -woven polyester fabric surfaced, SSS modified bitumen roof undedayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). 4.2 LasWbond Shield Is, a self adhering, woven polyethylene surfaced, SBS modified bitumen roof underiayrrient available in two widths, 36 and 45 inch; meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 Is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof und6dayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970. 4.4 Lastolmnd Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. meets ASTM D3970. Exterior Research and Design, LLC. Evaluation Report SM10AGAS-ILU M�JSSQ3 EDMON(2017)FBCNOWWWEVALUATION F125694U3 Soprew, Inc. Revision 11:10/06/;017 Paga2ofa 5. �7 I�l�TY I ERD TRI 4.5 Lastobond Pro HT N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch; meets ASTM D1970. 4.6 Lastobond Pro HT S is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM.D1970. 4.7 Lastobond 195 Is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.8 Lastobond: Eaves Protection Sheet is a.seWadhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roofunderlayment; meets ASTM U1970. 4.9 - Lastobond..-Eco is a self -adhering, glass -mat' reinforced, sand -surfaced, SBS modified bitumen roof �-- ndertayment; meets ASTM D1970. 4,11� RESISTO LB1236 is a self -adhering,_ glass=mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheetwidth; meets ASTM D1970. 4.12 PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlaymert with a 36-inch sheet width; meets ASTM D1970. 4.13 RESISTO LB1244 is a self -adhering,. glass=mat reinforced, sand -surfaced, SBS -modified bitumen roof underlayment, with a 44-inch sheet width; meets ASTM D1970. 4.14 Colphene FR GR is a sell -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof underlayment;. meets ASTM D1970 and FRSA/TRI April 2012 (04-12). LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on'iivhich1his Evaluation Report,.. or. previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is notfor use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report;.refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may: be -Used with any prepared roof cover where the product is specifically referenced within FBC approval documents':' If not listed, a request.may be made to the Authority Having Jurisdiction for.approval based on this evaluation combined with supporting data for the prepared roof covering. Sty ..- AllowableAoof.Covers: TAB[F� :RooF COVQt QPTioNS Underlayntent Asphalt,`= Nall -On Foam -On Metal Wood Shakes & Slate Shingles; Tile Tile Shingles Lastobond TU HT Yes - .Yes Yes Yes Yes Yes: See 5;5:1 Lastobond.Shield / Pro HT N J RESISTO SA?: SMOOTH PLY40 Yes Noy Nog _; No, Yes Yes. ' Lastobond Shield HT/ Pro HT-S Yes 111px Nc . Yes Yes Yes Lastobond Eaves Protection Sheet/ Yes No�IVo`i YesYes Lastobond 195 r Now Q' Lastobond ECO / RESISTO m236, Grip Rte Save &Valley Protector/ RESISTO Nor Yes Yes Exterior Research and Design, LLC. Evaluation Report 518010.06.09-R11 CffWcafe ofAarharka .n 09S03 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569 R13 Soprema, Inc Revision 11.10/06/2017 Page 3 of 8 QOTRII IMIIERD - - ,Frr Asphak vail-0n FUndedaymentoanh-01f ,Tf Metal WoodShalkes&' Slate Sifte" f Shilwes Lastoboad Smooth Seal HT Yes - ,_" n� '�:- Yes _Yes . Yes Yes Colphene FR GR Yes Yes. Yes ,- �' Yes See sm . 5-5-1 "Foam -On Tile" is limited to use of following Approved the adhesives / undedayment combinations. AtIhesile 11CPAdhesivesPolysetGAN-26o Honda ProdiictApproval Umicrlayments Dow ThleBond- FL22525 Lastobond W Fir FL6332 Lastobond 1U Hror Colphene Rt GR 5.6 Allowable Substrates: S.6.1 Direct -Bond to Deck: Lastobond Shield, LastobOnd Pro HT-N, RESISTO, SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, LaswWnd ECO, RESISTO L 82236, Grip -Rite Eave & Valley Protector. RESISTO LB2244 or Lastobond Smooth Seal HT applied to: ➢ Plywood; ASTM D41 primed plywood; 058, ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood; ASTM D41 primed plywood, ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow,Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond to4nsulation: Lastobond Shield, Lastobond Pro HT-N, RESlSTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 295, Lastobond ECO, RESISTO L81236, Grip4Ute Eave & Valley Protector, RESISTO L81244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tie systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1807. 2 Refer to Tile Manufacturer's orAdhesive Monufactumes flodda ProdoctApMval for ovwtuming Moment Resistance Perf rmance. Exterior Research and oes%n, LLG Qer�lmOeoJAoEhorieotbn6A5� 6'N EraWatlon RepoRSl8tri0: 9 WMCIX (20171 FOC K0*HVIR EVALUATM FLZ58569U3 4R13 Soprhshha, Inc Revisio:111:10/"/2017 Pm4of8 QOTPRJNnYIERD 5.6.3 Bond to Mechanically Attached Base Laver. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40. Lastobond Shield HT, Lastobond Pro HT S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195;' Lastobond ECO, RESISTO L61236, Grip -Rite Eave & Valley Protector, RESISTO L61244, Lastobond Smooth Seal HT or Colphene FR GR applied to: D ASTM D226, Type I or 11 felt, Sopra-G; Modified Sopra-G. For installations under mechanically attached prepared roof coverings, -base layer shall be attached per minimum codified requirements. For installations under foam -on file systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12), 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underpayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on file applications.. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI Apra( 2012 (04-12) or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure = -4S.0 osf: Deck Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. (Optional) Elastocol Sticky Elastocol 600c or RESiSTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colohene FR GR, self -adhered. #2 _Maximum Design Pressure = -67S asf• Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Efastocol600c Underlayment: . Lastobond TU HT or Colphene FR GR, self adhered. #3 Maximum Design Pressure =-1s0 0 nsf- neck: Min. 15/32-inch APA-rated SCX plywood (may be installed C-Ade up) to meet project requirements to satisfaction of Authority HavingJurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -laps. #4 Maximum Design Pressure = -60 0 asE Deck., Min. 19/324nch •plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Supra-6 mechanically attached with nails (FBC 15175.1) and tin caps (FBC 15175.2) spaced 6-inch o c. at the 44nch laps and 64nch o cr in three (3), equally spaced rows in the center of the sheet. Underlayment: , Lastobond TU HT or Colphene FR GP, self -adhered 5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on the systems carry a Maximum Design Pressure of -45 psi. Extr W Research and Des%% LLC. Pnkvnan Report 518D1UM0 4W Gert mteyau ONwra9l�o9 eEomox(zunFBcNoi wnfiVAwAiI m R2569-R13 Soprema, I m Revision 1L• 1. 0/WIM7 Pages orb 1 � jl TRINITY I.ERD 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure.for the selected assembly shall meet or exceed that required under FRSA/TRl April 2612 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance. with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI . WD1, FM Loss: Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies, marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 1016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond-Eaves-Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236 Grip -Rite: Eave & Valley Protector or RESISTO L61244 shall not be left exposed for longer than 30- days. afteririst-allation. Lastabond Shield, Lastobond Pro HT N, RESISTO SA SMOOTH PLY-40, Lastobond Shield HT or Lastobond Pro HT S shall not be left exposed for.long er than 90-days after installation. Lastoborid TLI HT or Colphene FR GR.shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlaym„ent in direct -deck the assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. A x TpeLE2 TILE$IIPPAGELIMRA'iIONSFORDIREC7-DECKTILEINSTAu:AT10N5: Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max :10-tile stack 5:12 Max.10-tile stack (bottom 2-tile stack shall be inverted,.followed by 8 tiles high 6:12 on slope; as shown below) Lastobond TU HT 4. Lugged j Colphene FR GR Flat Max ibLtile stack 5:12 Lugged Max.10-tile stack 6:12 Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R11 CerWcuteojAvthorlmtioa#9S03 e"EDITION(2017)FBCNONHVHZEVALUATION FL2569-RB Soprema, Inc Revision 11:10/06/2017 Page 6 of8 q0TRIt"MIERD 6. INSTAt1A'now: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER (if applicable). V«7�j�--*�������W��iJ'�.T�{Qf7�,�•�l��- f '•�F� t._ S+Y- i �; �1 �M���C��}wY�s! � ,`��ry JypM�MY�iW�¢!� �iJ+!� . g2 .„i? JC Y - �i•.:. 1.%-� ,63.1 Shallbeinstalled in compliance with the requirements for ASTM D1970 underfavment in �FBC Table 2507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile Applications: While priming is optional, Soprema. recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, pe6off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water- Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of the sheet at 124nch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation,Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on file applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and Soprema published requirements for file staging. 7. BUILDING POWITREt(UIREMENT3: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product I - Enerior Research and DwIgn, LM Evaivat(on ReportS18010.OSA9-Ril eeo/AadmrTmttare9�4olr 6'EDITION(20171FBC11101" WEVAWA710N R2569413 sopmmas hic. ReVislon 1k 20106/2Q17 Paxe7of8 �jTRHIM'MD MMUFACPMNG PLAIWM Contact the noted CIA agency for information on product locations covered for FJLC. 61620-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. I Aam LasInhand Weld, REMM SAMOM PLY40, Lastabond Sdeld HT, Drununondville, LasbDbond Pro trr-m Lmtobond Pro HT-% Lastoband 1W, Lwtobond QC (Canada) ASIM DIM Bnw ProWctmagmef4 taAobmd Eam, Liftband Smooth Seal HT RESIMIM23rx Wmw%urwGrip-Rite Ewe&ValWyPwft0w, MISTO LB1244 ASrM MM & FRSAfM 04-12 Calphene FR GR bmbobmrd M Las bond SMS PrOMMIJOn Sheet; LwWband Em, Wadsvjorft OH ASTM D1970 Wsk&wd Smooth Seal HT, REUM UWM PfimeSmum Grip-RAe lave & Valley PwUxW RE RM LM244 ASTM D1970 & RSAfM 04-12 Iaftbond TU W; Cdphme FH GR Laswmw M Lastobond raves Pmtmgon Steel; Lambond Eco, Gwipor% ms ASTM DL970 I Laftband&nooth Seal HT, RE' MO 183230 PdmeSouroeGM)-flMe I --- Eave&Valley Protect REASTOL01244 QUALITY ASSURANCE ENTITY. UL, LLC— QUA9625, (314) S78-3406, kchancellor@us.ul.com - END OF EVALUATION REPORT - Oftibritmearch and DeskkLLC- EyahmWnRepwtS1M0ALW4U1 Gs eojaotlrarkvEtmrlR 6P13)M0N(Z0MFBCN0N4MaEVALk;A7M I R2569-1113 Salmr,m, Im RWAS11M11:10106IM7 112080fe