HomeMy WebLinkAboutPROJECT INFORMATIONi FLORIDA o ®� ee®� 0eoe® a GUIX06St SUPPLY & MANUFACTURING PRODUCTTM GULFED L2) FLORIDA APPROVAL O 11651.22 R ST. LUCIE COUNTY Product Evaluation Report 13UILDING DIVISI REVIEWE GULF COAST SUPPLY & MANUFACTURING, LL .REVIEW �O YCOI1p N DATE 26 Ga. GulfRibTm Roof Panel over 75/32" PI o®C1I MUST BE KEPTOpIEyRN I OR NO INSPECTION WILL BE MADE Florida Product Approval #11651.22 R3 Florida Building Code 2017 Per Rule 61G20-3 THESE PLANS AND ALL PROPOSED WORK SCANNED Method: 1 -D ARE SUBJECT TO ANY CORRECTIONS 'BY REQUIRED BY FLEW Ilap'IQC'i C ^S TI;,;T St. �.ude C0u,�ty Category: Roofing MAYBE NECESU" IN ORDER TO Subcategory: Metal Roofing COMPLY WITH 'A', PjQ'PLIc'A''LE COD-S, Compliance Method: 61 G20-3.005(1)(d) NON HVHZ CONCUR FASTENERS 09ATTACHMEHn ARE THE RESPONSIBILITI' OF THE Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. CONTRACTOROFRECORD 14429 SW 2nd Place, Suite G30 `'' S. Newberry, FL 32669 ; `�OPN� r is-A-i Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 1651.22 R3 • OCTOBER 5, 2017 �.� sF -.ti No, 75519 STATE OF .' Q O R 10 P' • •a��:� oNA EN'20/05/2017 r i y- )VA L G61 �Cozk SUPPLY & MANUFACTURING Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfRibTM 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/a" Major Rib at 9" O.C. Panel Fastener: Substrate Description: Design Uplift Pressures: 11651.22 R3 •OCTOBER 5, 2017 #9-15x1.5" HWH with sealing washing or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Table "A" Max�rnum Total U lift DesiPre sure 59.25 sf 159 25 sfi' Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5 "-2.5"-6.5" ,Fastener Pattern Sp ciri �� Design Pressure includes a Safety Factor = 2.0. FLORIDA RRODUCT.APPROVAL Gulfc6&t SUPPLY & MANUFACTURING TIM GUILF2D L-RD� GULFRIBTM PANEL OVER ••D FLORIDA PRODUCT APPROVAL NO. 11651.22 R 7't-1 ' Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0062T 07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 7551.9) @ Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. 11651.22 R3 • OCTOBER 5, 2017 .PRODUCT APPROVAL G61i'coakt 'I SUPPLY & MANUFACTURING Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#1i111651.22 R3 •OCTOBER 5, 2017 G u"' I f Co"m ' la'sit SUPPLY & MANUFACTURING ENG WEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32" Plywood Build4ags,haV►ng?a Roof Meari�He)ght`sf20 Of ;``=Roof Slope 2'712i, x12�i1�2 Gable or ip"1. oof,��W..ind�5pe'edsLA20 + n,y„� Encl sed Buildl on FI'on'da Buiding Co 2'017 '`c'°' � MOWN �ph; Exposure ����.. �` 1:Sb C, R)sk,Categorys`ll g based .ram ,. a y'; .t. 120 130 140 150 160 170 180 WII D FASTENER SUBSTRATE SP D (MIN. 1/4" Penetration) (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZO i • » . • El 9 15x1 5';, Plywood r24' lYi?E1 24/ TYPE1 TYPE 9 ��24' TYPEti124 ;wTiYPEn7�24 k24 1TYPE1 p,y2�4,r�TYPE�1 ZO IE 2 #9-15x1.5" Plywood 24", TYPE 1 24", TYPE 1 224", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 2 ZO E 3Om #9 15x15 Plyvvoodt 24 TYPE1 *'#^aY4 f ±an^�A%W, TYPE 1 3 - 'F} ,ail`. 5+.>'�i TYPE 212', Y.+� - wa✓k TYPEr212 giG # .Y .N.? '� '�Ar, Y3le,�tlr` �12TpYPE 2�. ,',! ,24T§YPEP1�, f �24` ,�T,YPE2 1.) Pi! EL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL. 2.) P EL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF ® 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF Q 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) P&WOOD DECKING: MIN. 75A2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) L AD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING COD 2017. Z� ONE 2 HIP ROOF a Note: Dimension (a) is defined as 10% of the minimum width of the building or ZONE 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be J--—————--—— — — — — —a less than either 4% of the minimum width of the building or 3 feet. TYPE FASTENER PATTERN \\\ \\ RIDGE�9" 9" 9" { -1. \� \__------/ `/ I I At Panel Lap ZONE t \\ \ \ I L Cont Tape Seal for use on Slopes less than 3:12 (1) #9-15 x 1-1IT w/Sealer Washer @ 24' O.C. Max. 'TYPE 2 FASTENER PATTERN ZONE 2 GABLE ROOF Tad r-6.5°—# 2.5" {—�1111 2.5" {-6.5"te�25 "-6.5"- - '— — — — — — — — — a RIDGE LCant. Tape Seal far use on Slopes less than (1)9-15 x w/Sealer Washer @ ----- -- ------------+a --------------------- a I ZONE 1 \ I - -ZONE 3 `EAVE FL4111651.22 R3 • OCTOBER 5, 2017