HomeMy WebLinkAboutPRODUCT INFORMATION16/20/22 kW
True Power'm Electrical Technology
SCANNED
BY
St. LadeC®uffiv
Two Line LCD Multilingual Digital
EvolutionT"" Controller (English/Spanish/
French/Portuguese)
Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
Electronic Governor
System Status & Maintenance Interval LED
Indicators
Sound Attenuated Enclosure
Flexible Fuel Line Connector
Direct -To -Dirt Composite Mounting Pad
Natural Gas or LP Gas Operation
5 Year Limited Warranty
Capability to be installed within 18" (457 mm)
of a building*
TUBES
GENERALI -
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
Models G007036-0, G007037-0 (Aluminum - Bisque) -16 kW 60 Hz
Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz
Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz
INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's
success in providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need it the most. The
G-Force series engines are purpose built and designed to handle the rigors of
@LW
CQvIF-TEST-
Note: CUL certification only applies to unbundled units and units packaged with
pre -wired switches. Units packaged with the Smart Switch are UL certified in the
USA only.
*Only if located away from doors, windows and fresh air intakes,
and unless otherwise directed by local codes.
O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION;
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
extended run times in high temperatures and extreme operating conditions. electronically torque -matching the surge loads to the engine. Digital
voltage regulation at t1 %.
TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
form produce less than 5% Total Harmonic Distortion for utility quality power. This allows network provides parts and service know-how for the entire unit, from the
confident operation of sensitive electronic equipment and micro -chip based appliances, engine to the smallest electronic component.
such as variable speed HVAC systems.
TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are
J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
V ' SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
"'GENERAC
ryat7.36s ,�y� ��r
S O
PROMISE Mobile
� 2 QW * * Ltnk
sToraea �� hgRx►.�
+Beet M M. tlBAeelne eom&slrc end fineren pert.
GENERAC®
16 0/22 kW
features and benefits
Engi I
e
•
enerac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasmamoly rings helps the engine
run cooler, reducing oil consumption resulting in longer engine life.
• ",
piny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
• E
ctronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
• F
II pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur-
ing up to a 2 year/200 hour oil change interval.
• L
oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
• Hgh
temperature shutdown
Prevents damage due to overheating.
Gene
laItor
• R
4olving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
• Sewed
stator
Produces a smooth output waveform for compatibility with electronic equipment.
• D+
placed phase excitation
Maximizes motor starting capability.
• At�
omatic voltage regulation
Regulates the output voltage to ±1 % prevents damaging voltage spikes.
• I.
2200 listed
For your safety.
Trans I r Switch (if applicable)
• F automatic
Transfers your vital electrical loads to the energized source of power.
IIlIly
• NfiMA 3R
Can be installed inside or outside for maximum flexibility.
• Rellll ote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
Evolul,Ion" Controls
• Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
• TvJ -line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
• Se led, raised buttons
Smooth, weather -resistant user interface for programming and operations.
• Uti ty voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
• Ge erator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
• Uti ty interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a
qualified dealer.
• En, one warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
• En ne cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
• Pr( rammable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every
other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner.
• SrrIrt battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
• Map line circuit breaker
Protects generator from overload.
• Ele tromc governor
Maintains constant 60 Hz frequency.
Unit II
• SA weather protective enclosure
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150
mph. Hinged'key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat-
ically applied textured epoxy paint for added durability.
• Enc osed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Sm �I, compact, attractive
Makes for an easy, eye appealing installation, as close as 18" away from a building.
installation System
• 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Direll t-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system.
0 Inte ial sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
GENERAC
�16/20/22 kW
specifications
enerator
odel
13007035-0, G007036-0,
G007038-0, G007039.0 G007042-0, 0007043-0
G007037-0 (16 I(W)
(20 kW) (22 kW)
___-_n____ __
ti�ted Ma>amum —Cont Rower, Capacity(LP),
16;000 Watts"
_
20,000 Watts' 22;000 , • , • . ;
R ted Malumum Continuous Power Capacity (NG)
16.000 Watts`
18,000 Watts` 19,500
d V ' eoltage_
240 ..
240 240
R ited Maximum Continuous Load Current-240 Volts (LP/NG)
66.6166.6
83.3/75� 91.6/81.3
T Fit Harmonic Distortion -
Lessthan:5% • =
^Less ttian5% Less than 596—"•j
m Line Circuit Breaker
70 Amp
100 Amp 100 Amp
_.
N her of Rotor Poles
2
2 2
t ed ACequen ,Frcy ; , .. _.
w 60,HT
60 Hz _ '60Hz a
P er Factor
1.0
1.0 1.0
B� teryRegtijremept(not included) ,-, _ ,� -�
:. 12 Volts; Group 26R 54o CCA Miihim_um or Group.35AGM 650 CCA Minimum
_
Un t Weight (lb/kg)
406/186
448/203 466/211
Di ensions(LxWxH)1Wmm
48x25x29/121Bx`638x732'-
�
� M
� _ t
S nd output in dB(A) at 23 R (7 m) with generator operating at normal load
66
66 67
r f _ p M p rase mode" `
S nd output at 23 ft (7 m) with generator in atnet-Test- lows Bed exe
58
58 58 -
F rrlca rlrvatinn
a min
_ r min m1
JE
glne
T
e of Engine GENERAC G-Force 1000 Series GENERAC G-Farce 1000 Series GENERAC G-Force 1000 Series
ber of Cylinders 2
'
Di
placement� 999 cc �W 999 cc 999 cc
rCy,
nder.8(ock ,,. � Aluminum w/ Cast Iron Sleeve -•
Va
e Arrangement Overhead Valve Overhead Valve Overhead Valve
I`ti
Ig
w/ lion -, . , . .,: , Solid-state.Magneto - Solid-state w/, Magneto- . Solid-state:w/ Magneto
Go
lemor System Electronic Electronic Electronic _
(Cp
presston Ra to s v '.. , v _ 951: _ 9 51, w _ ° 9
St
rter 12 Vdc 12 Vdc
�I
Capacity Including Filter Approx. 1 9 gt/1.B L Approx 1 9'gt/1.B L Apprdx 1.9'gt/1.B L
Op
rating rpm 3,600 3,600 _ 3,600
Fu
Consumption
'Na
,
rat Gas ft3/hr (m3/hr) "
1/2 Load 218 6.17 204 (5 78) 216(6.12)
Li
Full Load 309 (8r75) ;{ 301 (8 Z8)a., 310 (8 78)
id Propane f ". ft3/hr,(gaVhr)
t
[I/fir] t
-
t
1/2,Load 91.6 (2.52) ]9 53] 86:(2 37) [8 991 93.2'(2.56) [970)
t
_ _ Full Load 129.643 56) [13:481 140 (3;87) (1465]
Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-71 water column (7-13 mm mercury) for natural gas,10-12" water column (19-22 mm mercury)
No
fort
P gas. For Btu content, multiply ft3/hr x 2500 LP or ft3/hr x 1000 NG . For Me a oule content, multiply m3/hr x 93.15 LP or m3/hr x 37.26 NG
C"ntrols
I
2-
a Plain Text Multilingual LCD Display Simple user interface for ease of operation.
Mo
eBuUons.Auto,. AutomahoStarton;lltGilityfailure. 7dayexerciser.,", „
M
al Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Oft•,
Stops unit:Power is removed _ _ Control and cr still operate.
_ _ -harge -
Re
y to Run%Maintenance Messages Standard
Eng
n+e Run Hours indication :Standard
r n.
ryammaole start oetay Between "L-lbuu seconds Standard (programmable by dealer only)
`„--„
Futi,
__�J •" 7 ^W""""��`• l"'� ���� yr �— f1U111 I4V-1l I V/ luu-L lu V
fe Set Capable Exerciser/Exercise Set Error Warning Standard
iRu 11 1IamVMamtenanceLogs Events Each
Eng e Start Sequence
_ Cyclic cranking 16 sec on 7 rest (90 sec maximum duration).
Sta _ °.. -- Starter 5sec
cannot re-engage until after engine has stopped.
Sm�rLock-out
rE Battery Charger Standard
Cha�¢eGFault/MrssmgAQWarmng,. - - Standard:
v
Low l attery/Battery Problem Protection and Battery Condition Indication Standard
Aut atic Voltage Regulation with Over and Under Voltage Protection
_Standard
Und -Frequency/Overload/Stepper Overcurrent Protection Standard
[Safe y Fused/Fuse Problem Protection - Standard -°�:. l
Auto atic Low oil Pressure/High Oil Temperature Shutdown Standard
rover (Q 72 Hz)/rpm Sense Loss Shutdown - Standard
Hight ngine Temperature Shutdown Standard -� V
Inter al Fault/Incorrect Wiring Prole_ ction -. �W Standards
Cam
on External Fault Capability_ Standard -
Field
pgradable Firmware Standard .
and levels are taken from the front of the generator. Sound levels taken from other sides at the generdtor may be higher depending on installation parameters. Rating definitions -Standby. Applicable forsupplying emergency powerfor the duration
of
ai ilitypoweroutage.Nooverloadcapabilityisavailableforthisrating. (All ratings in accordance with BS5514, IS03046 and DIN6271). * MWmum kilavolt amps and current are subject to and limited by such factors as fuel Blutmegajoule
can
nt,amblentlemperelure,alhtude,enginepowerandcondition,etc.ftmumpowerdecreasesabout3.5percentforeach1,000feet(304.8meters)abovesealevel;andalsowilldecreaseabout1percentforeach6IC(10°F)above16°C(60°F).
iI
Li
GENERAC®
kW switch options
i Circuits Switch Features
circuits, breakers not included.
ctrically operated, mechanically -held contacts for fast, positive
for all classes of load,100% equipment rated, both inductive and
pole, 250 VAC contactors.
) millisecond transfer time.
jai coil design.
ited for both copper and aluminum conductors.
Bin contacts are silver plated or silver alloy to resist welding and sticking.
=MA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
ounting flexibility.
ulti listed for use with 1" standard, tandem, GFCI and AFC] breakers from
emens, Murray, Eaton and Square D for the most flexible and cost effec-
re install.
200 Amps 120/240,10
Open Transition Service Rated
Height
Width
H1
H2
W1
W2
Depth
P
27.24
30.0
11.4
13.5
7.09
m
1
692.0
1 762.4
289.0
343.0
180.0
Note:�Illhe 50 amp switch isflush mountable. Ht and W1 refertomounting holespacing.
H2anW2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover.
Wire,panges
-71
III Conductor Lug
Neutral Lug
Ground Lug
1/0-#14
2/0-#14
210-#14
Seru, a Rated Smart Switch Features
• 1 cludes Digital Power Management Technology standard (DPM).
• 1'telligently manages up to four air conditioner loads with no additional
• ljp to four more large (240 VAC) loads can be managed when used in
on]unction with Smart Management Modules (SMMs).
• ectrically operated, mechanically -held contacts for fast, clean connections.
• ted for all classes of load,100% equipment rated, both inductive and resis-
t Ye.
•Q to four more large (120/240 VAC) loads can be managed when used in con -
I ction with 50 amp Power Management Modules (PMM**).
• ole, 250 VAC contactors.
•i rvice equipment rated, dual coil design.
• Rued for both aluminum and copper conductors.
• Fain contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
200 Amps 120/240,1 e
Open Transition Service Rated
Height
Width
Depth
I' H1
H2
W1
W2
in
1'127.24
30.0
11.4
13.5
7,09
mm
I692.0
762.4
289.0
343.0
180.0
Model
G007036-0 (16kW)
. :
2 _
- � -
Current Rating (Amps)
100
Voltage iating (VAC)
s 120/240,1H
Utility Voltage Monitor (Foced)*
-Pick-up
-Dropout
80%
65%
Returntb UUhty �
-" approx:'15 sec - , , ,
Exerciser bi-weekly for 5 minutes*f
Standard
UL Listedndard,�
Total Circuits Available
Tandem Breakd_ Capabrldres
16
_ - 8 spaces
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volts
10,000
Model G007037-0 (16 kW)/6007039.0 (20 kW)/
G007043-0 (22 kW)
Current Rating (Amps)
2000
VoltageRah�ng (VAC) �� �' �' ; :120/240,10 �_
Utility Voltage Monitor (Fixed)*
-Pick-up
-Dropout
80%
65%
Return t6. Utility •approx l3 sec S_
Exerciser weekly for 5 minutes*
Standard
Ul Lid sled --'
Enclosure Type
NEMA/UL 3R�
!F cuit$teaker Protected
22,000
Lug Range
250 MCM - #6
*Function of Evolution Controller
— wi
s .•,J
t
r
H1
DEPTH
I W2 --I
16/20/22 kW
GENERAC
11110111111111
available accessories
i Model # Product Descnpfion '
Generac',, Mobile Link allows you to check the status of your generator from anywhere that you have ac-
G006463-4 Mobile Link" � cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or�
! text message when a change in the generator's status occurs. Available in the U.S. only.
i G00
819-0
26R Wet Cell Battery
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPact®).
G00
101-0
Battery Pad Warmer
The pad warmer rests under the battery. Recommended for use if the temperature regularlyfalls below 0°F.
(Not necessary for use with AGM -style batteries).
(Oil
G00
102-0
Warmer
t Oil warmer slips directly over the oil fitter. Recommended for use if the temperature regularly falls below
0°F.
iThe breather warmer is for use in extreme cold weather applications. For use with Evolution controllers
G00
103-0
Breather Warmer
only in climates where heavy icing occurs.
_
Auxiliary Transfer Switch
I The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load
G
621 0
Contact Kit
you may not need. Not compatible with 50 amp pre -wired switches.
t
Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
G00
27-0 - Bisque
(Standard on 22 kW)
sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting
holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from
IG00
03-0 - Bisque
Paint Kit
future corrosion. The paint Idt includes the necessary paint to properly maintain or touch-up a generator
enclosure.
'11I
GOOD
85-0
Scheduled Maintenance Kit
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine
�
IIy
maintenance on a Generac automatic standby generator.
G006873-0
�
Smart Management Module
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
LL_
(50 Amps)
power management capabilities. It provides additional power management flexibility notfound in any other
power management system.
dimensions & UPCs
Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
LEFT SIDE NEW
resew
FRONT VIEW
Model
UPC
G007035-0
696471070354
G007036-0
696471070361
G007037-0
696471070378
G007038-0
696471070385
G007039-0
696471070392
G007042-0
696471070422
G007043-0
696471070439
GN E RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
11
02016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No.10000000194-D 10/03/16
LIMITS & REQUIREMENTS OF USE:
1) THE PAD AND THE SUPPORTED EQUIPMENT MUST BE LOCATED AT GROUND LEVEL. THIS TABLE DOES NOT APPLY TO ROOFTOP EQUIPMENT, EQUIPMENT LOCATED ON BALCONIES,
OR ANY OTHER EQUIPMENT TO BE ELEVATED ABOVE GROUND LEVEL,
2) THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS.
MINIMUM SOIL COEFFICIENT OF FRICTION = 0.25
3) MAXIMUM DIMENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. PAD WEIGHT TO BE VERIFIED BY OTHERS.
4) ORIGINAL EQUIPMENT MANUFACTURER INSTALLATION INSTRUCTIONS SUPERSEDE HURRICANE PAD INSTALLATION INSTRUCTIONS IF MORE STRINGENT.
5) ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.)
SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR.
6) ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, at. al. INDEMNIFIES & SAVES
HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION,
CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN.
7) THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE
ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE
COORDINATED BY THE PERMITTING CONTRACTOR.
8) THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE.
9) THIS ENGINEER SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE
SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN.
10) THIS ENGINEER SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO RE-EVALUATE THIS WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO
MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS.
11) ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION.
12) EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.
13) PADS SHALL BE CONSTRUCTED WITH PRECAST CONCRETE, MINIMUM COMPRESSIVE STRENGTH, fc=7,000 PSI AT 28 DAYS.
14) ALL OTHER UNITS NOT SHOWN SHALL BE DESIGNED ON A CASE BY CASE BASIS.
15) CONTRACTOR SHALL PROVIDE 5/8" DIA. (0.675" O.D.) GALV. TUBE ASTM A53B SCH 40 MIN, OR 1/2" DIA. SOLID COPPER BAR
SPIKE 4' MIN. EMBED. (SEE MIN. EMBED. AS PER CURRENT ELECTRICAL CODE, BY OTHERS) INTO GROUND THROUGH CONCRETE
PAD FOR SLIDING RESISTANCE PURPOSE,12 DIAMETERS EDGE DISTANCE FROM ANY CONCRETE FACE (NOT SHOWN).
16) PADS / UNITS INSTALLED DIRECTLY ON ANY COASTLINE REQUIRE A HEAVIER AND LARGER PAD
TO ACCOUNT FOR EXPOSURE D ; Table 28.3-1; Kz = 1.03
ENGINEERING DATA:
1) ANALYSES PER 6th EDITION (2017) FLORIDA BUILDING CODE - SECTION 1620 HIGH VELOCITY HURRICANE ZONES.
2) WIND LOADS & LOAD COMBINATIONS PER ASCE 7-10 SECTION 2.4.1 (LOAD COMBINATIONS), SECTION 29.5 &
FIGURE 29.5.1 FOR: WIND LOADS ON OTHER STRUCTURES
3) RISK CATEGORY = II TABLE 1604.5 - RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES, SECTION 301.15 OF
THE MECHANICAL CODE, WIND RESISTANCE, AND 553,844 OF THE FLORIDA STATUTES WIND STORM LOSS MITIGATION.
4) WIND LOAD: Wind Speed V =
185
MPH (RISK CATEGORY 11)
F = geG•Cf Af (Eq. 29.5-2) =
74.63
'Af (lbs)
qz = 0.00256 • Kz • Kzt • Kd • VA =
PSF
Exposure C Table 28.3-1 - Kz
_67.03
0.85
µ
Figure 26.8-1 i z -
1.00
DiverslTech Corporation
Table 26.6-1 Kd =
0.90
6650 Sugarloaf Parkway #100
1f80G)
Figure 29.6-1 Of =
1.31
Duluth, GA 30097
G =
0.85
397-4823
MI11///�j/i
No. 80017 =_
I r
STATE OF .'��`
0RIOP'-'',��
//;/_10IVA1- E�G����
3,1.1-18
lillli I:NGI\7'sI'sl ING LIB(;
Solving Problems to Minimize the Stress of Doing Business
31.3 In.
GE ERAC
GENkIIN TOR
54.3 In. PAD LENGTH
TYPICALANCHORAGE: (OTY-3)
114' DIA. - 51n loop. BOLTS. 3' MIN. EDGE
DISTANCE. 1318' EMBED. INTO CONCRETE
(BASE PAN MIN. THICKNESS- 0.69'AND MIN.
BEARING STRENGTH - 6 KSI)
1 .........
1
ii i 7
AIR
-COOLED
UNIT / EQUIPMENT
FG8341-413
PAD USED FOR ALL
185 MPH
0.6(UNIT+
PAD)
WEIGHT
LBS.
RESISTING
MOMENT
FT-LBS.
DESIGN,.
CHECK
MAXIMUM DIMENSIONS
INCHES
MINIMUM
WEIGHT
LBS.
MODEL
NUMBER
(2pc PAD)
WEIGHT
LBS.
PAD
WIDTH
IN.
2pc PAD
LENGTH
IN.
PAD
THICK
IN.
WIND
LOAD
LBS.
0.6(WIND
MOMENT)
FT-LBS.
PAGE1Of1
WIDTH
LENGTH
HEIGHT
GENERAC 09kW
25
48
29
340
FG5431-413
275
31.3
54.3
4
721
667
369.0
481
OK FOR
0
MPH
GENERAC 11kW
25
48
29
348
1`135431-413
275
31.3
54.3
4
721
667
373.8
487
OK FOR
0
MPH
GENERAC 16kW
25
48
29
406
FG5431-4G
275
31.3
54.3
4
721
667
408.6
533
OK FOR
0
MPH
GENERAC 20kW
25
48
29
448
1 FG5431-4G
1 275
31.3
54.3
4
721
1 667
433.8
566
OK FOR
0
MPH
GENERAC 22kW1
25
1 48
1 29
466
1 FG5431-4G
1 275
31.3
54.3
4
721
1 667
444.6
580
1 OK FOR
0.
MPH
H
LIMITS & REQUIREMENTS OF USE:
1) THE PAD AND THE SUPPORTED EQUIPMENT MUST BE LOCATED AT GROUND LEVEL. THIS TABLE DOES NOT APPLY TO ROOFTOP EQUIPMENT, EQUIPMENT LOCATED ON BALCONIES,
OR ANY OTHER EQUIPMENT TO BE ELEVATED ABOVE GROUND LEVEL.
2) THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS.
MINIMUM SOIL COEFFICIENT OF FRICTION = 0.25
3) MAXIMUM DIMENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. PAD WEIGHT TO BE VERIFIED BY OTHERS.
4) ORIGINAL EQUIPMENT MANUFACTURER INSTALLATION INSTRUCTIONS SUPERSEDE HURRICANE PAD INSTALLATION INSTRUCTIONS IF MORE STRINGENT.
5) ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.)
SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR.
6) ENGINEER SEALAFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, at. al. INDEMNIFIES & SAVES
HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION,
CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN.
7) THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE
ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE
COORDINATED BY THE PERMITTING CONTRACTOR.
8) THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE.
9) THIS ENGINEER SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE
SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA, THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN.
10) THIS ENGINEER SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO RE-EVALUATE THIS WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO
MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS.
11) ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION.
12) EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.
13) PADS SHALL BE CONSTRUCTED WITH PRECAST CONCRETE, MINIMUM COMPRESSIVE STRENGTH, fc=7,000 PSI AT 28 DAYS.
14) ALL OTHER UNITS NOT SHOWN SHALL BE DESIGNED ON A CASE BY CASE BASIS.
15) CONTRACTOR SHALL PROVIDE 5/8' DIA (0.675- O,D.) GALV. TUBE ASTM A53B SCH 40 MIN, OR 1/2' DIA, SOLID COPPER BAR
SPIKE 4' MIN. EMBED. (SEE MIN. EMBED. AS PER CURRENT ELECTRICAL CODE, BY OTHERS) INTO GROUND THROUGH CONCRETE
PAD FOR SLIDING RESISTANCE PURPOSE, 12 DIAMETERS EDGE DISTANCE FROM ANY CONCRETE FACE (NOT SHOWN).
16) PADS / UNITS INSTALLED DIRECTLY ON ANY COASTLINE REQUIRE A HEAVIER AND LARGER PAD
TO ACCOUNT FOR EXPOSURE D ; Table 28.3-1; Kz =1.03
ENGINEERING DATA:
1) ANALYSES PER 6th EDITION (2017) FLORIDA BUILDING CODE - SECTION 1620 HIGH VELOCITY HURRICANE ZONES.
2) WIND LOADS & LOAD COMBINATIONS PER ASCE 7-10 SECTION 2.4.1 (LOAD COMBINATIONS), SECTION 29.5 &
FIGURE 29.5.1 FOR: WIND LOADS ON OTHER STRUCTURES
3) RISK CATEGORY = II TABLE 1604.5 - RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES, SECTION 301.15 OF
THE MECHANICAL CODE, WIND RESISTANCE, AND 653.844 OF THE FLORIDA STATUTES WIND STORM LOSS MITIGATION.
4) WIND LOAD: Wind Speed V =
165
MPH (RISK CATEGORY II)
F = gz'G'Cf'Af (Eq. 29.5.2) =
74.63
'Af (lbs)
qz = 0.00256' Kz' Kzt' Kd ` VA2 = 67.03
(_Exposure C Table 28.3.1 Kz = ��0.85 l
v
PSF
Figure 26.8-1 Kzt ==
1.00
DiversiTech Corporation
Table 26.6-1 Kd =
0.90
6650 Sugarloaf Parkway #100
1(800)
Figure 29.5.1 Cf =
1.31
Duluth, GA 30097
Ra
G = 0.85
397-4823_
No. 80017
�
STATE OF 4
11il YONAI.
3,Jul-18
1111111 ENGINEERING' lili��
Solving Problems to Minimize the Stress of Doing Business
31.3 in.
--
PAD WID
GENERAC
GENERATOP'.
-54.3 In. PAD LENGTH
TYPICAL ANCHORAGE: (OTY-3)
1N. CIA.- 5In long. BOLTS, 3' MIN. EDGE
DISTANCE, 1.316' EMBED. INTO CONCRETE
(BASE PAN MIN, THICKNESS - 0,69- AND MIN.
BEARING STRENGTH - 6 KSI)
ca cr____ - - ___-_-c_n cc i
1 _ i
S � •l
UNIT
�4Ac
AIR
COOLED" -
UNIT / EQUIPMENT
FG8341-4G
PAD USED FOR ALL
185 MPH
0.6(UNIT+
PAD)
WEIGHT
LBS.
RESISTING
MOMENT
FT-LBS.
-
DESIGN
CHECK .
MAXIMUM DIMENSIONS
INCHES
MINIMUM
WEIGHT
LBS.
MODEL
NUMBER
(2pc PAD)
WEIGHT
LBS.
PAD
WIDTH
IN.
2pc PAD
LENGTH
IN.
PAD
THICK
IN.
WIND
LOAD
LBS.
0,6(WIND
MOMENT)
FT-LBS.
PAGE 1 of1
WIDTH
LENGTH
HEIGHT
GENERAC 09kW
25
48
29
340
FG5431-4G
275
31.3
54.3
4
721
667
369.0
481
OK FOR
0 _MPH
MPH
GENERAC 11kW
25
48
29
348
FG5431-4G
275
31.3
54.3
4
721
667
373.8
487
OK FOR
`0-
MPH
GENERAC 16kW
25
48
29
406
FG5431-4G
275
31.3
54.3
4
721
667
408.6
533
1 OK FOR
0
MPH
GENERAC 20kW
25
48
29
1 448
1 FG5431-4G
1 275
1 31.3
1 54.3
1 4
721
1 667
1 433.8
566
1 OK FOR
0 -
MPH
GENERAC 22kW
1 25
48
29
1 466
1 FG5431-4G
I 275L
31.3
1 54.3
1 4
1 721
1 667
1 444.6
580
1 OK FOR
'0
MPH