Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONTM J Gulf�ost ® SUPPLY & MANUFACTURING Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC 26 Ga. GulfRibTm Roof Panel over 15132" Florida Product Approval #11651.22 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)(d) NON HVHZ SCANNED By St Lucie Countv ood ST. LUCIE COUNTY BUILDING, DIVISION REVIEWED FOR COMPLI CE REVIEWED Y DATE N7o /!a PLANS AND PE IT MUST BE KEPT O JOB OR NO INSPECTION WI_L BE MADE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY COPRECTIONS REQUIRED W FlU INSPECTORS THAT UAY BE WCESSARY IN ORDER TO COMPLY WITH ALL APPUCA&E CODES, Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 + tgF-L S' %',,, Newberry, FL 32669 : +OP' ' C r: A" , 1-�41 Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL# Ill651.22 R3 •OCTOBER 5. 2017 * No, 75519 STATEoF s�S�0R1DP •���.� ., , �G\ ,;oNAL E%"10/os/2o27 CONCFALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD , - i, , , � :, 1 ,I j k .,I , i r) JN, TM Compliance Statement: Product Description Panel Material/Standards- Panel Dimension(s): Panel Fastener: Substrate Description: Design Uplift Pressures: 1651.22 R3 • OCTOBER 5, 2017 G 61iCoLw� *s\ t SUPPLY & MANUFACTURING The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. GulfRibTM 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/a" Major Rib at 9" O.C. #9-15x1.5" HWH with sealing washing or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building• Code 2017, Section 1506.6, 1507.4.4 Minimum15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Table "A" Maximum Totalli� IIftDeslnPressure� 9 69�25psf �..=p_ .flU w „� ,pt1592�5'psf�Y': Fastener Pattern 9"-9"-9"-91, 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" �"' s rid rdZ •, � S;g''� ) Fasteners Pattern Spada, g � Ir '��?' T1�5's�"'>'d 24 ®C t 1 � �i; 12" opC. v ar t a. eaaaa a nr ram'• Design Pressure includes a Safety Factor = 2.0. f {- 61 :� t GC®as SUPPLY & MANUFACTURING TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0062T-07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3.12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. 111651.22 R3 • OCTOBER 5, 2017 � � „� ,. ` it ¢ •_ mom. I it GullC®ast ® SUPPLY & MANUFACTURING TM Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 1,1651.22 R3 • OCTOBER 5, 2017 GulfCdao tQ SUPPLY & MANUFACTURING ENQINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32" Plywood Buildings hav(ng a Roof Mean Height s.20 0 , Raaf Sjope 2"(12' 1.2'/12 'Gable orsHlp Roof Wind Speeds 120 180 j ph, Exposure C ;Risk Cafegory it Ehciosed i3u)lding -based on Flonda BufldingCode2017 Tz .; 120 130 140 150 160 170 180 W1 ND FASTENER SUBSTRATE SF ED (MIN. 1/4" Penetration) (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING 'NE 1 `� #9-1.Sx1 5"; Plywood � �24 TYPE 1, 241 TYPE 1�' 24"� TYPE 1, 24 TYPE 1)Y 24 �,tTYPE 1„; 24 TYPE 1 24 TYPE1 I ZOINE 2 #9-15x1.5" Plywood 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 2 ZONE 3 #9-15X1 5 Plywood 24 TYPE 1 24 TYPE 1- 24 TYPE1 "72 TYPE 2 `,�12 TTYPE Z>; �i2 TYPE 2 12 TYPE 2` d 1.) PANEL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL. 2.) INEL FASTENER. #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.)AXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) P DECKING: MIN. 15/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) IYWOOD OOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING C09E 2017. zONE2 NIP ROOF a ZONE Note: Dimension (a) is defined as 10% of the minimum width of the building or be 40% of the mean height of the roof, whichever is smaller, however, (a) cannot j -----------------,a less than either 4% of the minimum width of the building or 3 feet. ^ \ / /� `I \\ / I TYPE 1 FASTENER PATTERN \ RIDGE // \ �--------J I I I " At " p I At Panel La 9":q� i ` ZONE 1 \\ \ I L peal for use on Slopes less than 3:12 (1) #9-15 x 1.1/21 w/Sealer Washer @ 24' O.C. Max. ------------------� SAVE ZONE 2 GABLE ROOF TYPE 2 FASTENER PATTERN Tad2.5" 6.5" 2.5" 6.5" 2.5" 6.6 2.5" --------------------- I I RIDGE L Cont, Tape Seal for use on Slopes less than 3:12 ----- ------------- — I (1) #9.15 x 1.1/2° w/Sealer Washer @ 12' O.C. Max. a a +----------------------I I ZONE 1 ' ZONE —EAVE 11651.22 R3 • OCTOBER 5, 2017