Loading...
HomeMy WebLinkAboutMANUAL­�_ VZ Ridge caps (pg. 9) Eave drip (pg. 8) Valleys (pg. 12 (Pg Gable rakes 11) Wall flashin s (pgs. 10 - 1 K Transition & gambrel flashings (pg. 10) - 75:; F _ Corner trims (pg. 13) Door & window trims (pg. 14) Base drip (pg. 14) Pipe Boot (pg. 111) Electrical Boot Reflective bubble insulation Inside Closures'`- _ . Outside Closures ® Flex-o-vent ® Profile Vent Expanding Foam Peel and Seal Touch-up Paint S/D"TEK La TEK P -. Butyl Tape Titebondv Woodgripe Screws TEK screws WoodZacID screws WoodMac screws Guide to Misc. Accessories item pipe boot Fits over vent and heat pipes. Available also in heat -resistant boots. electrical boot Fits around pipes with inaccessible tops (such as weatherheads). outside closures Required to seal under ridge caps and transition and endwall flashings. inside closures Seals under panels, particularly on the eave. Profile Vent, Flex-o-Vent! Vented closure material surpassing many other venting systems. expanding foam Compressed adhesive foam_ expands to.seal between valleys and panels. Peel and Seale Seals hips under hip caps. Also, a general purpose sealing tape (6" wide). touch-up paint -- Hides scratches and mars encountered in installation.,Over 20 colors. butyl tape General purpose low-cost sealant,_ used on panel laps and under trim. _Titebond® A.superior general purpose caulk for all joints. Matches. panel colors. _ Low profile insulation Greatly reduces radiant heat when installed under panels. Woodgrip screws Used in all applications attaching metal to wood. 1 ", 1%", 21/Z" sizes. TEK screws Self -drilling TEK screws for metal purlins. Lap TEK screws draw together joints and attach trim. ZACe screws "Lifetime" screws; 11/2", 21/2", threaded for wood; self -drilling available. 1K 5F, elfGulf o St �� ® SUPPLY & MANUFACTURING Gu'lf e' ' SUPPLY & MANUFACTURING The Gulf Coast Gulf Who Roofing Panel Gulf Coast Gulf rib' panels are a strong, -durable,_ economic, and -attractive=answer -to the growing demand for metal roofing needs in Florida and southern Georgia. Extremely versatile, they are suitable for homes and businesses as well as agricultural and utility buildings Gulf Rib' panels provide a 36- inch coverage with 3/4 inch ribs on nine -inch centers, and utilize an anti -siphoning channel Figure 1 The Horseshoe Beach Gulf Coast Supply to provide protection from severe weather office (left) and manufacturing facility. conditions. Both panels `and trim are fabricated I "° A " , ce:c ucI ` using state-of-the-art computerized equipment �.,.: 1.10 .Jac'k onville, TaIlaFiasse found at our facilities in three locations in Florida, �•r �_:� ► f to assure uniformity and consistency in product ; j *Aldcfiva �Hor`seshoe* manufacture. Panels are roll -formed to the lengths Ocala Beach" specified by customers in either Galvalume or ! l - I-75 , Orlando f any of more than twenty colors of painted 29- a I r�OaIDA !' i gauge, 26-gauge, and 24-gauge high -tensile metal,--,Tdmpa,; ' ready for either customer pickup or on -site deliv- * . ery (customers should call about availability of Sebring. 24-gauge metal). Your Gulf Coast representative' ;Stuart is waiting to assist you in making the best choice Qurfof for your particular roofing needs. Miami Gulf Coast's Gulf Rib' panels are fabricated EV from AZ-50 (painted) or AZ-55 (bare - -- - - Galvalume ) grade 80 coil stock (grade 50 for 24 Figure 2 The 4 locations of Gulf Coast Supply. bare Galvalume finish is not only durable and cost effective, but offers reflectivity so valuable here in the South. The paint system employed on painted - products offers optimum exterior protection plus superior resistance to corrosion and ultraviolet radiation. While bare Galvalume carries a 25-year �-- limited coil manufacturer's finish warranty, most painted metal carries a 40 ear war- ranty. Both painted and unpainted are of the highest known quality in the industry. Gulf Coast also stocks a complete line of fasteners, sealants, and other accessories to meet every need of both the do-it-yourself homeowner and the roofing contractor. A complete line of both in -stock and custom-made flashings and trims are available in all colors as well. �' GULF R'18' DETAIL MANUAL Gutters Pop - Gulf Coast Supply produces 29-, 26-, and 24- gauge gutters in either 5- or 6-inch widths (depth is approximately equal fo =width). All gutters should be ordered specific to the pitch of the roof. Downspouts are available in Yx4" (for 5- inch gutters) and 4"x4" (for larger gutters). End caps should be ordered at the same time as the gutters to assure a custom fit. Special hangers fit into the panel rib and under the gutter lip. Panels should extend no more than 1" to 1'/z" inches beyond the eave on which gutters are planned. ' lap 5 or 6"-- Gutter hangers fit inside panel rib and under lip of gutter (apply at least one per panel) and are attached with lap screws or rivets. Figure 21 Exposed view of gutter showing gutter hanger placement, downspouts, and end caps. Hangers employ lap screws, and end caps are best attached with rivets. Inner _-� Outer __Inner _—`> Outc Inner and outer gutter sections (marked `I" and "O") alternate along the eave to assure ease of application and gutter appearance. Downspouts in excess of 10 feet in length must be made in 2 sections. Figure 22 Sliding door track covers fit over the door track and under the panels to hide the track, assure a neat appearance, and shed water overthe door. ® Track Covers ;II TC-1 sliding door track cover ,1. Figure 19 The drip cap is commonly used to trim out the bottoms of panels over doorways and windows, and occasionally takes the place of base drip. J-channel is used to cap raw panel edges where run-off is not a problem, and is most commonly used to trim around the bottom, sides, and occasionally the top of windows and doors, and also to cap the top sides of skirting. Base Drip 0; IIIIIIIII k G u"' If C o""an 0s; t' SUPPLY & MANUFACTURING Drip- Cap -and J-Channel DC-1 E j Drip cap ® 1 2'/z' I capping the panel end ® JC-1 J-channel panel 7/8 I ` 2 ,�4��� �► cappinghe panel edge I G _(! il� Figure 20 Base drip seals off the bottoms of panels at the floor level, where it helps to prevent the entrance of rodents and insects, as well as a base for the setting of panels. UUITLoast SUPPLY & MANUFACTURING all a$ion-oUP-an els Roof Pitch Gulf Coast roofing panels require a certain degree of pitch to ensure proper water drainage. Florida Building Code allows a minimum pitch of 2/12 for Gulf Rib® panels as long as lap screws Lap screws and sealant are optional when the pitch is 4/12 or greater (4/12 pitch means that there is 4 inches of rise for every 12 inches running horizontally). As a general principle, the less steep the roof, and the more necessary also that sealant be used at all side -laps. Consult our representative for recommendations for your particular roof pitch, and about roofing options if you have less than a 2/12 pitch. • Roof Preparation Oil -canning is a wave -like, rippled appearance extending up the length of the panel after it has been installed on the roof. Any irregularities in the roof, including uneven plywood joints, warped plywood, uneven trusses, poor application of underlayment, the use of button caps with felt paper, etc., can promote oil -canning. Care should be taken to provide a flat, uniform surface on which to attach the panels. See page 6 for more details. Roof Application Panel installation should begin at the gable end of the roof opposite the prevailing rain -bearing wind (this will provide added assurance against wind -driven rain being forced under the laps). Measure one panel width in from the roof edge. At this point chalk a line from ridge to eave. Place the leading edge of the first panel along this line. It is extremely important that this panel be laid square to the eave and ridge so that the remaining panels will line up square on the roof frame. It is wise to have a person at the eave and at the ridge to ensure that the proper panel coverage is being maintained across the roof. Also be sure that the panels are properly side -lapped (see fig. 7 on page 7). In applications where end -lapping is necessary, the upper panel on the slope should lap over the panel that is lower on the slope by about 12 inches. Lesser roof pitches require a greater amount of panel overlap. All end -lap applications should use two horizontal rows of butyl sealant tape across the panel and proper fastening to provide a maximum water seal. An overhang of 2 to 3 inches on the eave is recommended to provide a drip edge, while only 1 inch overhang is necessary where gutters are used. The open panel ribs at the eave can be sealed with inside closures. For maximum weather -tightness, a row of butyl tape can be applied above and beneath closure material. Trimming and Cutting Steel Panels • The best device for cutting steel panels across the profile is either hand snips or a nibbler. Nibblers, and especially Carborundum blades on electric saws, however, do have a tendency to either leave hot metal particles that can burn paint surfaces or to leave rust marks on panels and trim. The same is true of any filings left on the roof caused by the application of screws. Care should be taken to brush all such particles from roof surfaces after application. To cut panels lengthwise: Note carefully where the panel is to be cut, and, using a straightedge, score deeply down the length of the panel with a sharp -pointed utility knife. Folding the panel along the score mark, and bending back again if necessary, should produce a clean break in the panel. CAUTION! clean all metal shavings and particles off of roof to avoid unsightly rust stains � ry GULF RIB- DETAIL MANUAL � Residential Trim Seep. 12 for Siding Trims Roll Lite Door Transition Flashing (p.10) Figure 4 Roofing trims and flashings are named by the location or function of that particular piece on the building. Valley Ridge cap Figure 5 Butyl tape or caulk -is required when the roof pitch is 3112 or less, with lap screws applied every 2 feet to maintain water -tightness of the lap. On pitches greater than 3/12, lap screws and butyl tape are optional. For more details on screws, see pgs. 6 and 7. GULF RIBS" DETAIL MANUAL � GR-2 Outside Corner 10 The GR-2 Rake and Corner can be used as a gable=trim= or a- corner-for-metal=sided -buiidings.- As an alternative, the smaller EF-1 or the GR-1 (both on p.11) can also used as gable rakes, and the PC-5 (below)or the GR- I as comers. Customizing rakes or corners is often necessary due to their landing on a panel rib. Both the GR-2 and the IS-2 can be ordered as custom trim items by specifying custom dimensions "a" or "b". B sure to take into account the 3/4" "head space" when figuring custom dimensions. — The PC-5 flat corner panel � � � works best on smaller 3' structures, and where the panels are running ;outside horizontally. It can be ;closure sealed with outside closures. Q PC-5 t Jul Figure 17 When used as corner trim, the GR-2 straddles the ribs of the panels where they meet at the corner of the building. The Gulf Rib outside corner also serves as a gable rake (see below). The inside comer (IS-2) has similar dimensions but with a reverse middle bend. Figure 18 When used as a gable rake, the GR-2 runs parallel to the ribs of the roof panel, and is attached with screws running through the ribs of upright siding. As with the EF-1 residential rake, the roof side can be sealed with butyl sealant. Gable Rake 4 5/8" -- Preformed Valley from diverter ypanel 22 4 9v��> PV 1 sty J I. PV 2 style Two basic styles of valley are available. For custom valleys, specify dimension "a" �� s--- Gul Cast -GUItCdaKt SUPPLY & MANUFACTURING SUPPLY & MANUFACTURING — - - -- - -- - -- — -- - Ordering Roof -Panels -and -Screws -- Care should be taken to order panels of the correct length to avoid having to make corrective measures after purchase. Panel lengths should fall 2 to 3 inches short of the ridge when ceted ride is desired, and should extend 2 to 3 inches past the eave to allow a sufficient drip edge (except as noted on pg. 3 concerning gutters). When a roof transition is involved, panels of the upper portion should be ordered short to allow placement of the transition flashing (see diagram on p. 10). The Gulf Coast sales personnel are ready to assist customers with information specific to their particular roof. Specially-washered screws applied through the flat of the metal is the most recommended method used to attach roofing panels. 1-inch screws can be used if penetration of only 3/4 inch is ✓✓✓ either necessary or desired; otherwise, 1 %2 inch screws are usually recommended. 2'/z inch screws ° are also available, and are often used by those who adhere to through -the -rib fastening, and for ridge -cap application. See pages 6 and 7 for more information on screw spacing and ordering. Figure 15 Pre -formed valleys use a diverterto preventwater from rushing under panels on the opposite side, while meanwhile channeling water off the roof. Expanding foam closures are often used to assure a good seal. Gulf Coast Gulf Rib® Siding Figure 16 Common trims associated with Gulf Rib roofing panels Ordering and Applying Trim The most common flashing for metal roofing is the ridge cap, which is used at the peak of a roof where two opposing roof slopes join. Other flashings include transition flashing, end wall and sidewall flashings, and valleys (see diagram on right for application). Eave trims include gable flashing and eave drip, either of which are often applied above fascia trim. When roof pitch exceeds 5/12 (a 5 inch rise in 12 inches), the slope of the roof should be mentioned when ordering ridge caps, endwalls, and eave drip. When a steeper roof slope meets a lesser slope, both slopes should be mentioned when ordering transition flashing. At the gable edge the use of gable trim adds to the appearance of the structure and protects the fly -rafter, and sidewall flashing is used where the side of a panel butts up against an adjacent wall. In either case, the installer should be careful to seal between the gable rake or sidewall and panel with butyl sealant tape, and to fasten the rake every 6" to 12" up the slope of the roof with the appropriate screws. If eave drip is used on the gable, the number of 90 degree eave drip should be specified separately from that used on the drip edge when ordering. To prevent penetration of water, insects, and debris at the ridge, outside closures should be inserted between the ridge cap and the top end of the panel. Screws are applied through the ridge cap, closure, and rib in at least every other rib of the panels. At least a 1 %2" (or preferably 2'/2") screw should be used for attaching ridge caps. Self -drilling lap screws can also be used to attach ridge caps. Keep Materials Dry! Paint and finishes of Gulf Coast panels and trim are designed to withstand severe rain and wet weather conditions. Neither paint, galvanized, or Galvalume finishes, however, are designed to be in continuous contact with water for long periods of time. Damage will result if uninstalled panels or trim are allowed to remain wet in storage. Be sure to store material that will not be installed immediately in a dry location. Wet material should be air-dried and re -stacked if installation is not planned right away. GULF RIBS' DETAIL MANUAL How to Figure and Apply Screws Gulf Coast Supply carries screws in 3 different lengths: 1 inch, 1'h inch, and 2 '/z inch. 1-inch screws will barely penetrate a 1 x4, but the 1'/z inch are the -best all=purpose-size. =1'7Z= or 2%-inch screws are necessary for attaching ridge caps. The table on the right can be used to figure approximate quantities of screws for various purlin spacings and sizes of roofs. For 2-foot spacing between rows of screws, multiply the total linear feet of metal times 2.7 Example: your order is 1250 feet of Gulf Rib roofing. 1250 x 2.7 = 3375 screws Please confirm all estimates with your Gulf Coast representative when you placed your order. Screw (nurlin) Snacin 12 inch 18 inch 24 inch 0 50 210 180 135 100 540 360 270 0 2001 1080 720 540 a 300 -1620 -1080=-- 810 - - 400 2160 1440 1080 c 500 2700 1800 1350 ¢ 600 3240 2160 1620 0 700 3780 2520 1890 800 4320 2880 2160 900 4860 3240 2430 , 1000 5400 3600 2700_ 11001 - 5940 . 3960 2970 . 1200i 6480 4320 3240 'Figu eT671 lu VKiib panelsP Codes allow re -roofing over shingles without the use of battens calculation chart - provided the roof has been checked by a licensed roofing contractor to insure levelness and pullout integrity. Gulf Rib metal roofing can be separated from the moisture barrier by minimum, nominal 1 "x3" yellow pine battens spaced on maximum 24"centers, or according to ASCE calculations where applicable. Since direct contact between pressure treated lumber and metal roofing must be avoided in order to prevent potential corrosion, Gulf Coast Supply sells only untreated battens. CAUTION: Battens must be fastened to the roof deck with minimum #6 screws at 12" on -center, or two minimum 8d common or pneumatic nails spaced 8" on -center, or one every 4" on -center (or by applicable calculations according to ASCE 7-98). Battens must be installed to support the entire width and length of ridge, eave, hip, valley, and gable -end trims. For solid decking, at least 15/32-inch structural plywood supported on rafters at a maximum of 24" on center is required. If care is taken, metal roofing application can be aided by pre -drilling panels, allowing screws to go quickly and accurately into the desired spacing. Pre -drilling will work provided that pilot holes are placed accurately in the proper locations on panels. Purlin spacing must be uniform and carefully measured. For panel lap details, see Figure 5 on page 4. Gulf Coast Policies Delivery policy Delivery charges apply to all orders where delivery is requested. Please consult your Gulf Coast sales department for details. Sales tax All orders picked up at Gulf Coast Supply, and all orders delivered within the state of Florida, are subject to state sales tax. Tax exemptions should be verified prior to delivery or customer pickup. Warrantied products A 40 year warranty applies to most material* manufactured from painted coil stock, and a 25-year warranty:to Galvalume material. Ask for details. Indemnity All prices and designs are subject to change without notice Disclaimer While we have made every attempt at accuracy in this manual, we are not responsible for typographic, printing, or technical errors. Oil Canning —a repeating, wave -like appearance in the length of the panel —is a common and often unavoidable phenomenon in metal panels like Gulf Rib roofing that have large, flat areas within the panel. It is therefore not a defect, nor a cause for rejection. See p. 3 for details on how to avoid oil -canning. Return policy All panel orders and special order (non -stock) trims are considered the property of the customer and non- refundable once they are manufactured. Standard trim and accessories are refundable providing they are returned in a clean, resalable condition. For details, go to www.gulfcoastsupply.com and click on "No Hassle Return Policy" at bottom of page, or call Gulf Coast Supply to ask specific questions about returns. GULF R!IV DETAIL MANUAL Gable Flashing Pp, Er-1 s1yie , o Custom trim —specify a custom R length for a or b. Standard dimensions — a = 3" b=3" GR-1 style Custom trim —specify a custom length for a or b. b Standard dimensions — a = 2 3/8" b = 2 3/8" New of standard sidew'ailltrim View oJ EP-1 gable trim ascia board remove Figure 13 Gable flashing is used to trim the edge of the roofing panel at the gable end of the roof. It should match the eave drip that extends along the drip edge of the roof. If the panel is allowed to hang over the gable end, eave drip can be used instead. Butyl tape between the trim and panel eliminates leaks. ® Side -wall Flashing caulk (Solar Sealo recommended) caulk edge (order SW -IC) (used if sidewall not covered by siding) 3" 311 Butyl tape 3/4" \ ,l 5 11 Figure 14 Sidewall flashing is applied when the side of the SW-1 roof butts up against an adjacent wall. The wall -side of the flashing can either be covered over with siding or sealed Custom trim —specify a custom with caulk (order SW -IC). Butyl tape should be applied length for a or b. 1 �� where the "foot" of the flashing attaches to the roof. Standard dimensions — a = 3" b=3" a G-bIfC®ast SUPPLY & MANUFACTURING End. -Wall slashing End -wall flashing is applied where the upward slope of a roof meets a wall. The wall side of counter -flashing, and edge (order EW-1C) (used if endwall not covered by siding) Figure 11 As with the ridge cap, the ENDWALL FLASHING above is sealed using outside closures. LEW-1 Stepped Use EW-2 hemmed endwall when cornering endwalls with sidewall b Endwall flashing, such as with dormers or chimneys. For custom end -walls, speck roofpitch and dimensions "a" and "b". a_ Transition Flashing Oil, The TRANSITION FLASHING prevents leakage at the point where two different roof pitches meet. It must be sealed on the lower side with outside closures, and can be sealed underneath the upper panels with inside closures. The similar GAMBREL FLASHING is used where the lower pitch is steeper than the upper. TF-1 Transition Flashing closure _. , ., — b For custom transition flashing specify the pitches of the two roof slopes and, if necessary, dimensions "a" and "b". Figure 12 The transition flashing (above) and the GF-1 gambrel flashing (right) provide a continuous drainage where two slopes meet. Both seal with outside closures on the lower side. outside closures are necessary to seal between the flashing and the panel. Roof slope should be mentioned if roof exceeds 5/12 pitch. UUITLoast SUPPLY & MANUFACTURING Ga>tfl-f Coast Guif-Rilb® Roolr1g-Panefls- - - Fastening Schedule for Various Wind Speeds - minimum 2:12 roof pitch Wind Speed Zone _430-PH 14111 MPH 0_MPH 160 MPH Roof Fastener Fastener Size Attaching to: On Center On Center On Center On Center Zone Type Spacing Spacing Spacing Spacing Zone 1 woodgripO or #9-15 x 1'/Z min.15/32 24" 24" 24" 24" WoodZac ® plywood T e l yp T e l yP T e l yp T e l yp Zone 2 Woodgrip® #9-15 x 1'/z min.15/32 24" 24" 24" 24" Woodzac® plywood Type 1 Type 1 Type 1 Type 2 Zone 3 Woodgrip® woodzac® #9-15 x 1'/z min.15/32 plywood 24" Type 2 24" Type 2 24" Type 2 24" Type 2 Fastener pattern Type 1 I Type 2 - I I I I EW-2 Hemmed 1 / Endwall Zone 2 a �a a = 4%" Eave a ~� ........................................ ... = 311 F:/ ....................... ..........................,...........................................� a -:---------------- Ridge ---------------- --;F- ..........I Zone 1 Gable Fastener pattern Fastener patterns Type 1 and Type 2 are shown at left, row spacings are shown in the table above, and roof zones are displayed on left below. Figure 7 shows a simple illustration of the patterns. Note that fastener pattern Type 2 is required at top, bottom, and end laps of each panel, as well as in additional areas according to which roof zone the fasteners fall in. Each "zone" of the roof has its own screw requirements. Dimension a is defined as 10% of the minimum width of the building, or 40% of the mean height of the roof, whichever is smaller; however, a cannot be less than either 4% of the minimum width of the building, or 3 feet. Figure 7 Screws should be placed on both sides of the ribs at both eave and ridge, and on the overlap side of any panel laps. F.Wq 3 - ------------ Eave drip with fascia and inside closure Figure 8 Eave drip and fascia give a finished look along the drip eave of the house, as well as providing protection for the materials they cover. The eave drip should completely cover the top edge of the fascia. Inside closures, which seal off the open ribs of the panels, are optional. Gulkoast SUPPLY & MANUFACTURING ® Eave Drip & Fascia FHA Style Eave drip 1 Eave drip a Fascia a _l —►I b N— ED-3 Style 2 3/g" Eave drip 7 4 R For custom eave drip, specify the amount of the eave that will be covered (dimension "a"), and, for steeper roofs, specify pitch. If fascia is desired, be sure that the dimension you order will be hidden by the eave. drip. Summary of Stock Trims and Flashings item special order information Ridge caps (RC-2) specify pitch if less than 3/12 or greater than 6/12. Also available in larger widths. Closures recommended. Eave drip (FHA, ED-3)' 2 common styles. FHA style is pre -pitched for 3/12 to 6/12 roofs. For jappearance or ease of application, order by either specific pitch or as gable trim (901). Gable flashings Residential (EF-1), large (GR-2), and small (GR-1) rakes available. Use butyl sealant between rake and panel. Valleys (PV 1) j specify pitch if greater than 7/12. Seal with universal foam closure material. Open -hemmed valleys (PV 2) aid water -tightness. Sidewall (SW-1) Use butyl sealant between sidewall flashing and panel. Endwall (ENV-1) Specify pitch if greater than 5/12. Seal with outside closures. Transition flashing Specify pitches of both roofs. Seal lower slope using outside_ closures and, if desired, inside closures on upper slope. I i- . - MT, \�a IG'ULF R'IB,'m DETAIL. MANUAL Ridge Cap l000. The Ridge Cap is used to seal the point at which two upward slopes meet. This can be both along the ridge of the roof as well as a covering for a hip. Either woodgrip or self -drilling lap TEK screws are applied through the ribs of the metal. Since debris, insects, and blowing rain can find easy access under the ridge cap, closures are required to either completely or partially seal the opening. Closures under ridge caps come in 3 types: solid, vented, and hip tape. Solid closures ("Outside Closures") are (right). the same width as the panels. They lock together in a row placed directly under the screws that attach the ridge cap, and form a solid, water -tight, air -tight barrier. Profile Vent® comes in 50 foot rolls, is 3 inches wide, and forms a water - retardant, insect resistant barrier that allows hot air to escape from the attic, and is superior to many more elaborate and expensive vent systems. Any length may be ordered. Hip closure tape (Peel and Seal") is a sticky, adhesive -backed metallic tape that seals the hip roof. It is 6 inches wide and comes in 33'/z foot rolls. Because it must be conformed to the rise and fall of the panel ridges, approximately 10% extra may be needed beyond the length of the hip being covered. Outside 6„ / Profile Vent"' closure or j Versa -Vent' f\Lap or 2'/2" Woodgrip e ---w screw required RC-2 Standard 12-inch Ridge Caps are strong, economical and adequate for most of your roofing needs RC-1 style 12-inch Ridge Caps are also available in custom widths Figure 10 Pipe Boots provide a water -tight seal around roof vents and come in a variety of sizes. They seal with caulk and conform to the shape of the panel ribs. a� RC-2 style over -sized ridge caps are available with 18-inch coverage, or as a custom trim item in total widths (2 times "a") of 14-, 16-, 18-, 20-, 22-, and 24-inch