Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC.
26 Ga. GulfRibTm Roof Panel over 15132" Plywood
Florida Product Approval #11651.22 R3
Florida Building Code 2017
Per Rule 61 G20-3
Method: 1 —D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61 G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 PNML SI'/f�,�
Newberry, FL32669 O.•',rvEN".,y%
Engineer Evaluator:
Dan Kuhn, P.E. #75519
Florida Evaluation ANE ID: 10743
Validator:
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1 — 5
11651.22 R3 • OCTOBER 5, 2017
* , No, 75519 ;
-a =
STATE OF
�'�,; ONA L EN�io/o5/202 j
GuIX66st
SUPPLY & MANUFACTURING
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
Product Description:
GulfRibTM, 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage,
through fastened roof panel over minimum 15/32" Plywood Decking. Non
Structural application.
Panel Material/Standards:
Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2017 Section 1507.4.3.
Paint Finish Optional
Yield Strength: Min. 80.Oksi
Corrosion Resistance: Panel Material shall comply with Florida Building
Code 2017, Section 1507.4.3.
Panel Dimension(s):
Thickness: 0.018" Minimum
Width: 36" Coverage
Rib Height: 3/a" Major Rib at 9" O.C.
Panel Fastener:
Substrate Description:
Design'Uplift Pressures:
11651.22 R3 • OCTOBER 5. 2017
#9-15x1.5" HWH with sealing washing or approved equal
1/4" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4
Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this
evaluation. Must be designed in accordance w/ Florida Building Code 2017.
Table "A"
Max um use
692M5 psf
59-5 '
TatalUplftesignPr�es
}�sfgIT
Fastener Pattern
9"-9"-9"-9"
6.5"-2.5"-6.5"-
2.5"6.5"-2.5"-6.5"
Fastener�Pattern SpacingLIM
4' ®.C.
Design Pressure includes a Safety Factor = 2.0.
W
Zu\� _ .` OGufc6 t
SUPPLY & MANUFACTURING
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with.the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL 1897-12 - Uplift Test for Roof Covering Systems.
Reference Data: 1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 117-0062T-07A, B, Dated 02/19/2007
2. Certificate of Independence
By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC
(FBC Organization # ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test
standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005(3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including
Section 1507.4.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per Manufacturer's recommended details.
Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1.
11651.22 R3 • OCTOBER 5, 2017
i`
GuIX&&
SUPPLY & MANUFACTURING
TM
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10
using allowable stress design. The maximum fastener spacing listed herein shall
not be exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
FL#I11651.22 R3 • OCTOBER 5, 2017
GulfC6&t
SUPPLY & MANUFACTURING
ENGI
I EER LOAD TABLE: 26 Ga. Gulf RibTM Panel over 15/32" Plywood
Bi�ldi
180h;°Exposure
igs, }atring a Raaf iViean Height 20 0",toaf 5f4pe 212 ' 12 ;/12`K Gab(e'orHlp Roof,>Wincl Speeds
C; Risk Category Ifi,Fnelose Building, based on F(or►da Builcing Cade'2017 ' '
120
130
140
150
160
170
180
WII
SPED
D FASTENER
'(MIN 1/4"
Penetration)
SUBSTRATE
(MIN. 15/32")
ON CENTER
SPACING
ON CENTER
SPACING
ON CENTER
SPACING
ON CENTER
SPACING
ON CENTER
SPACING
ON CENTER
SPACING
ON CENTER
SPACING
Plywood
'24" TYpE 1
24"' TYPE try"
24 7YPE 1
24 TYPE 1
` 24 > TYPE 1 "'4",
TYPE (
z4" TYPE
ZO
E 2 #9-15x1.5"
Plywood
24"", TYPE 1
24"', TYPE 1
24", TYPE 1
24", TYPE 1
24", TYPE 1
24"", TYPE 1
24", TYPE 2
Q11E
3, , #9 15X1 S"
Plywood
24 ; TYP^E�1
24 k, TYPE 1»a
°24, TXPE1`
a�
72 TYPE'2
12 1TYPE 2^
�
%12TYPE 2 r
x
12 } TTYPE 2-
1.) PA
EL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL.
2.) P41,
I EL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL
3.) M
PSF @
4.) PL
XIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25
h 2" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
WOOD DECKING: MIN. 75/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE'2017.
5.) R
OF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
6.) L
AD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE
2017.
ZONE 2 HIP ROOF a
ZONE 3
JA-----_tea
--RI—_—_—ZONE1
ZONE 2 GABLE ROOF Tad
�—— — — — — — — — — — — — — — — — — is
I
I
--RIDGE �
I
ZONE1
'-ZONE3 —SAVE
1651.22 R3 • OCTOBER 5, 2017
Note: Dimension (a) is defined as 10% of the minimum width of the building or
40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
less than either 4% of the minimum width of the building or 3 feet.
TYPE FASTENER PATTERN
At Panel
Cont. Tape Seal for use on Slopes less than
#9-15 x 1-1/2" w/Sealer Washer @ 24" O.C. Max,
TYPE 2 FASTENER PATTERN
Cont. Tape Seal for use on Slopes less than
#9-15 x 1.1/2" w/Sealer Washer @ 12" O.C. Max.