HomeMy WebLinkAboutFSCE CERTIFICATIONFLORi FSEC 9 S902 FOS E C C LvZT I RCA 110A a ENERGY CENTER A94 Lk'_soL R � i t id —32 22 57e3— �321}636- Solar Enerl System �AS2.®ton DEC "rmitting C NOV 93 St, Luele BY 4305 W. Alva St. Tampa, Florida 33614-7636 St. LudeCount The system listed below was evaluated by the Florida Solar Energy Center (FSEC) in accordance with the Florida Standard Program for Solar DomesticWaterand.Pooi Heating Systems (FSEC-GP-80-7) and was found to,"et the minimum standards established by FSEC. Description designates various model suffixes Collector I Model Units Total Rating Amer. Energy Tech. AE-40 _ I 38;100 Btu 2 3 4 Tank " I Model Capacity 0 Direct- I •1 - Mor-Flo, SSTA-8I-EXV 82 gal. ❑ Int- Heat Exch. 2 Mor Flo: ST-82-EV/TEy 82 gal- 3 Rheem giv-80-Te-i _82 sal.__ . 4 Ruud RSTC-80-1 82 gal. 5 American SE52-80H--085S 82 gal_ 1 Hartel C23 7 Watts 11100 H.P. -_March 809-Bg 12124 48 Watts 1/100 H-P. - 3 4 Controller I Model,, ❑ Differential Temperature t Hosaa H-1004✓ ❑ Absolute Temperature 2 Sour x MS7E=1t) D Thermosephon 3 - W Other Photoiroltaic 4 Freeze protection by thermaL freeze proof valve and manual draindown. Other I Major Components y Eaton -Dole EP-45 Freeze Prevention Valve in addilion -to above 2 ME V-243 Freeze Piotection Valve 3.314" ID plains must be used on entire solar loop. d " ` If further information is required you may contact the Florida Solar Energy Center at the above address- ST. LUCIE COUNT BUILDING DIVISION REVIEWED F C MP ANCE $ PY REVIEWED BY FILE DATE PLANS AND PERMIf MUST BE .-KEPT ON JO OR NO INSPECTION WILL BE MADf. L,d I 1.00L £Z6 b96 Z# e5P3JeneJ 841 ebL:LL LL R7. JeIN SOLARTHERMALCOLLECTOR(S} VACUUM BREAKER AUTOMATIC AIR VENT ��PPESSURERFLIEFVAI LTAIC AUTOMATIC FREEZE VALVE ROOF PEN ETRATION COPPER TUBING & INSUL_ ATION LOW OLTAGE P.V. 1RES I 9ED i BLA K- _ f - -BACK--FLUSH VALVE! MANUAL DRAIN CIRCULAPR ON/OFI PUMP F SWfiCH � CHECK VALVE MANUAL DRAIN n n BALLVALVE BALL VALVE (I OLATION VALVE) (ISOLATION VALVE} -�- HOT WATER TO HOUSE COLD W,9 TER FROM HOUSE -- ELECTRICAL SUPPLY I 1 TEMPERATURE & f I RESET BUTTON I I I 1 PRESSURE RELIEFVALVE- EATING ELEMENT SOLAR RETURN FROM THERMOSTAT CONTROL I f I COLLECTOR I �► i�ti SOLAR FEED TO i I I SOLAR HOTWATER TANK COLLECTOR I I I I l I��E It 0. -TANK DRAIN LOOL EZ6 1,96 Z# 66P31SA9� 6U L Eb V L L L L 87, SSW s � i The new degree of comfort." Professional Classic° tankless electric water heaters offer continuous hot water quick and on demand for single point=o user=m-ultipfe=applications Performance Features • On demand, consistent and endless hot water • Compact and stylish with digital temperature control in increments of 1 T ranging from 80T to 140°F* • 99.8% Energy efficient • Robust copper immersion heating elements with brass top increases durability and are threaded for easy replacement • Simple Installation • Digital temperature display • External controls to adjust temperature in increments of 1 °F* Applications • Whole -Home — up to 6 GPM • Water -Saver Shower Head —1.5 GPM • Standard Shower Head — 2.0 GPM • Standard Hand Sink — 0.5 GPM • Kitchen Sink-1 to 2 GPM •Bath Tub —a4GPM • Dishwasher —1 to 2 GPM • Washing Machine —1 to 1.5 GPM Average Gallons Per Minute (GPM) based on 2010 Plumbing Standards Warranty • 5-Year heating chamber and 1-year parts limited warranty See Residential Warranty Certificate for complete information *RTEX-04 and RTEX-06 only show output temperature and are non -thermostatically controlled MODEL NUMBER TEMPERATURE RISE °F 0.5 GPM 1:o GPM 1.5 GPM 2.0 GPM 2.5 GPM 3.0 GPM 4.0 GPM 5.0 GPM 6.0 GPM RTEX-04 48° - - - - - - - - RTEX-06 75° 37° - - - - - - RTEX-08 - 55° 36° 27° 22' 18° - - - RTEX-08(derated 208V performance) 79° 40° 27' 20° - - - - - RTEX-11 - 75° 50° 38' 30° 25' - - - RTEX-11 (derated 208V performance) ' - 56° 37° 28° - - - - - RTEX-13 - 89° 59° 44° 1 36° 30° 22° - - RTEX-13(derated 208V performance) - 69° 46° 34° - - - - - RTEX-18 - + 82° 62° 49' 41° 31° 25° - RTEX-1 8 (derated 208V performance) - 90° 60° 45° 36° 30° - - - RTEX-24 - + + 82° 66° 55° 41' 33° 27' . RTEX-24 (derated 208V performance) - + + 60° 48° 40° 30° 24° 20° RTEX-27 - + + 92° 74° 62° 46° 37° 31° RTEX-27(derated 208V performance) - + + 68° 55° 45° 34° 27° 23° RTEX-36 - + + + 98° 1 82° 62° 49° 41° RTEX-36 (derated 208V performance) - + + 1 91 73° 1 61° 45° 1 36° 30° +Temperature electronically limited setting on adjustable thermostat on front cover RTEX-04, RTEX-06 Unique Features: • External Digital Display - shows outlet temperature • Durable Copper Immersion single heating element, field serviceable • Simple Installation - 3 Foot electric cable included; Bottom 112" NPT water connections RTEX-08, RTEX-11, RTEX-13 Unique Features: • atemal Adjustable Digital Thermostatic Control with LED display (+/-1 degree accuracy) • Durable Copper Immersion two heating elements, field serviceable • Simple Installation - 3 Foot electric cable and 1/2 NPT adapters included; Side 1/2' compression water connections 1r l RTEX-18 Unique Features: • External Digital Thermostatic Control with LED display (+/-1 degree accuracy) • Most advanced self -modulation, adjust power to meet hot water demand • Durable Copper Immersion two heating elements, field serviceable • Simple Installation - Bottom 3/4' NPT water connections Residential Electric w Water Professional Classic ..w Tankless Water Heaters RTEX-04 RTEX-06 RTEX-08 TEX-11 RTEX-13 RTEX-24 RTEX-27 RTEX-18 RTEX-36 c �*1r Tested and certified by the I IY, Water Quality Association against NSF/ANSI 372 for Intertek �� • lead free compliance. See specifications chart on back. RTEX-24, RTEX-27 Unique Features: • External Digital Thermostatic Control with LED display (+/- 1 degree accuracy) • Most advanced self -modulation, adjust power to meet hot water demand • Durable Copper Immersion three heating elements, field serviceable • Simple Installation - Bottom 3/4' NPT water connections RTEX-36 Unique Features: • External Digital Thermostatic Control with LED display degree accuracy) • Most advanced self -modulation, adjust power to meet hot water demand • Durable Copper Immersion four heating elements, field serviceable • Simple Installation - Bottom 3/4' NPT water connections PRINTED IN U.S.A. 01/17 WP FORM NO. TKE-101 7 ne new degree of Comfort:". Specifications Residential Electric Water Professional Classic Tankless Water Heaters DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) RECOMMENDED MIN. MAX.. SHIP BREAKER RECOMMENDED FLOW FLOW WATER WEIGHT MODEL NUMBER JkW AMPS SIZE VOLTAGE WIRE SIZE [GU) (GPM) (GPM) HEIGHT WIDTH DEPTH CONN. (LBS.) RTEX-06 5.5 29A (1x30)A 220 10AWG 0.3 4.8 1 5-7/8 1 10-7/8 2-3/4 1 1/2 NPT 4.5 RTEX-08 8.0 33A (1x40)A 240 8AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 7 RTEX-08 (derated 208V performance)` 5.8 .28A (1x40)A 208 8 AWG 0.3 4:8 12-5/8 8-1/4 3-5/8 1/2 CF 7 .RTEX-11 11.0 46A (1 x50)A 240 6AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 8.5 RTEX-11 (derated 208V performance)' 8.2 29A (1 x50)A 208 6 AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 8.5 RTEX-13 13.0 54A (1x60)A 240 6 AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 8.5 RTEX-13 (derated 208V performance)' 10.1 49A (1x60)A 208 t6 AWG 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 8.5 {Ewa RTEX-18 18.0 75A (2x40)A 240 8 AWG tO.3 7.0 18-1/4 14-1/2 3-1/2 3/4 NPT 14.78 RTEX-18 (derated 208V performance)' 13.3 64A (2x40)A 208 8 AWG 7.0 18-1/4 14-1/2 3-1/2 3/4 NPT 14.78 r RTEX-24 24.0 100A (3x40)A 240 8AWG 0.3 7.0 18-1/4 17-5/8 3-1/2 3/4 NPT 17.8 RTEX-24 (derated 208V performance)' 17.5 84A (3x40)A 208 8 AWG 0.3 7.0 18-1/4 17-5/8 3-1/2 3/4 NPT 17.8 RTEX-27 27.0• 112A (3x40)A 240 8.AWG 0.3 7.0 18-1/4 17-5/8 3-1/2 3/4 NPT 17.8 RTEX-27 (derated 208V performance)' 20.0 96A (3x40)A 208 8 AWG 0.3 7.0 1 18-1/4 17-5/8 3-1/2 3/4 NPT 17.8 RTEX-36 36.0 150A (4x40)A 240' 8AWG 0.3 8.0 18-1A 21-5/8 3-1/2 3/4 NPT 22.7 RTEX-36 (derated 208V performance)` 26.6 127A (4x40)A 208 8 AWG 0.3 8.0 18-1A 21 55/8 3-1/2 3/4 NPT 22.7 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure. Suggested Specifications Product Rated Pressure 25 PSI min., 150 PSI max. Unit shall have copper clad immersion heating element(s) with brass Specifications Certifications ETL Listed to UL 499 and CSA terminations for increased durability. External temperature control (all models) Std. Temp. Settings 120"F (Adjustable 80"F-140"F) and display adjustable in 1 ° increments with a range of 80°-140°F. Temp. Accuracy +/-1" at Steady state flow - Display shall be capable of displaying setpoint temperature in Turn -On 0.3 GPM Celsius or Fahrenheit temperature scales. Unit shall utilize a flow meter with a 0.3 gpm activation point and manage power based on actual flow rate and inlet temperature. Values should be processed 60 times per second. Unit shall be WQA certified lead free, certified to UL499 and CSA22.2. Optional Inline Flow Regulator Suggested Sizing Guide • Enhanced outlet temperature control • Install on the outlet side of the heater • Limit maximum volume to the specified flow rate to ensure exiting temperature is within an acceptable range • Flow Regulators for 1/2" and 3/4" plumbing connections • Flow range: 1 to 5 gallons per minute RHEEM PART NUMBER GPM RATING OF INSERTS PROVIDED CONNECTION - SIZE RTE10001A 1.0, 1.5, 2.0 1/2" NPT RTE10001B 2.0, 3.0, 4.0, 5.0 3/4" NPT COLD CLIMATE (INLET TEMP. 35-45°F) WARM CLIMATE (INLET TEMP. 50-60-F) HOT,CLIMATE (INLET TEMP. 65-75-F) RTEX-04 N/A N/A N/A RTEX-06 N/A N/A N/A RTEX-08 RTE10001A RTE10001A RTE10001A RTEX-11 RTE10001A RTE10001A RTE10001A RTEX-13 RTE10001A RTE10001A RTE10001A RTEX-18 RTE10001B RTE10001B RTE10001B RTEX-24 RTE10001B RTE10001B RTE10001B RTEX-27 RTE10001B RTE10001B RTE10001B RTEX-36 RTE10001B RTE10001B RTE10001B Selection based on inlet temperature and an outlet temperature setting of 105"F In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem.com Info@rheemus.com • Toll Free 800.374.8806 Manufacturers National Service Department 400 Captain Neville Road, Waterbury, CT 06705 PRINTED IN USA 01/17 WP FORM NO. TKE-101 U O Z ¢�<c &j Zz3"J3 j W < n d Zi�d D6 O 0c�w� 'z 6zc= 7 F-4r„ LILL wo>oa om g>¢c< ziDo� W nw¢w SCOPE OF WORK: - DESIGNED PER: WIND LOAD: WIND: RISK CATEGORY II SOLAR SYSTEM COLLECTOR: APPLICABLE CODE: (.IDVVIM.L1r RAISED OR ELEcrreoNlc SEAL MAY NOT BE USED FOR PLANs..:-.,.c, INSTALLATION OFASOLAR WATER HEATING ASCE 7-10 MODEL: AE.21/AE-24/AE-2611,.28/AE32/AEdO/ 2010 FLORIDA BUILDING CODE PAPER COPYEVERY IT PULLED OF THIS PLAN REQUIRES A SEALED ELECTRONIC PLAN OR SEALED ORIGINAL SYSTEM WITH A ROOF TOP COLLECTOR DESIGNED FOR 200 MPH EXPOSURE CATEGORY D{ASC21/MSC32/MSC40/SHC-21/SHC32/SHG-40 The LeverEdge DOMESTIC HOT WATER (DHW) INSTALLATION NOTES: GENERAL THIS DRAWING AND THE SPECIFICATIONS HEREON ESTABLISH THE MINIMUM REQUIREMENTS FOR DHW EQUIPMENT ON BUILDINGS IN FLORIDA 60 FEET OR LESS IN SLEIGHT AND AT ROOF ANGLES FROM FIAT UP TO 4S DEGREES. PER THIS PARTICULAR INSTALLATION DOCUMENT, The Le —Edge DHW SOLAR PANELS MAY BE INSTALLED PARALLEL TO THE ROOF PLANE WITH HOLD DOWNS FLUSH ON TOP OF THE UPPER SURFACE OF THE ROOF COVERING OR TILTED -UP TO ACHIEVE COLLECTOR OR 4-ANCHORS FOR TWO COLLECTORS THRU USE OF APPROVED RACKING TO TIE THE TWO COLLECTORS TOGETHER -SEE FIGURE 2. TILT -UP IS PERMITTED ONLY WITH THE FOLLOWING STIPULATIONS: A) NO INSTALLATIONS OUTSIDE OF PRESSURE ZONE 1; B) USE ONLY OEM HARDWARE- EXCEPT 414 TEKS PER FIGURE 2; C) COLLECTOR LONG AXIS HORIZONTAL AND 30 DEGREES MAXIMUM TILT ANGLE; DI WIND ZONE 140 MPH AND LESS REQUIRE 4-ANCHORS PER TILT -UP COLLECTOR; F) WIND ZONES GREATER THAN 140 MPH REQUIRE 6 ANCHORS PERTILT-UP COLLECTOR AND MINIMUM TILT POLE WALL THICKNESS OF 1/8TH-INCH. CONTRACTOR SHALL KEEP LAG BOLT LOADING TO UNDER 528 POUNDS OF UPLIFT. REFER TO WHEN STRAYING INTO P22, INCREASE ANCHORS 50%ON THE PORTION OF THE COLLECTOR IN PII. ABSOLUTELY NO INSTALLATIONS IN PZ3. TESTING: The LeverEdge DHW COLLECTORS HAVE PASSED MIAMI TESTING LABS WIND LOAD TESTING OF-102 PSF PER ASTM E-330 (MTL FILE NUMBER 95-1249).TIIIS ENGINEER HAS EVALUATED THE INSTALLATION COMPONENTS AND HARDWARE CURRENTLY PROVIDED BY The LeverEdge AS OEM INSTALLATION KITS AND FOUND THEM TO MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE CURRENT AS OF THE DATE OF THIS PLAN. THERE SHALL BE NO SUBSTITUTION OF OTHER VENDOR MATERIALS WITHOUT PRIOR APPROVAL OF THIS ENGINEER THRU The LeverEdge. HARDWARE: THIS ENGINEER HAS DETERMINED THAT THE HOLD-DOWN HARDWARE AND FASTENERS SUPPLIED BY The LeverEdge WILL WITHSTAND HURRICANE FORCE WINDS UP TO AND INCLUDING 200 MPH 3-SECOND GUSTS. THE ONLY REMAINING VARIABLE OF SIGNIFICANCE IS THE ATTACHMENT OF THE HOLD DOWNS TO THE UNDERLYING ROOF SYSTEM USING OEM HARDWARE. LAGGING OF TLE DHW CO R N ELECTORS D FLUSH MOUNT OWED IN EXPOSURE (PARALLELCATEGH THE ROOF SURFACEAND Z ROSETHERETOAS PERMITTEDBY OEMHARDWARES SHALL AALLOWED IN STHR2CATEGORYBAND C AND IN BOTH P21 AND PII AT MEAN ROOF HEIGHTS OF 66ROR LESS AND IN ALL WIND ZONES THRU 200 MPH SO LONG AS TIE FOLLOWING CAUTIONARY RULES ARE OBSERVED. LAGS SHALL BE CORROSION RESISTANT STEEL, 3/81NCH DIAMETER MINIMUM OR BETTER LAGS SHALL ACHIEVE AT LEAST 3-INCHES OF THREAD EMBEDMENT IN RARER OR BLOCKING. MEASUREMENTS MUST BE CAREFULLY MADE AND PILOT HOLES SHALL BE DRILLED TO ENSURE HITTING UNDERLYING RAFTERS OR TRUSSES AND TO AVOID WOOD SPUTTING. SPECIAL PROCEDURES TO USE WHEN, IN THE INSTALLER'S OPINION. HITfI NG THE CENTER OF TRUSS OR RARER WITH A LAG CANNOT BE ASSURED. EITHER USE A 3/8INCH (MIN)"r BOLT GRABBING THETRUSS/RARER OR 3/8 INCH DIAMETER (MIN) ALL THREAD ROD PLUS STANDARD FENDER & LOCK WASHERS AND NUT THRU MINIMUM 4" BY 4' BY 9" BLOCKING ON THE UNDERSIDE OF THE ROOF SHEETING. WHERE BLOCKING METHOD IS USED, INSTALLER 514ALL APPLY A GENEROUS BEAD OF CONSTRUCTION ADHESIVE FOR MINIMUM OF 1 RAWNG THE NEAR JOINTS OF THE ROOF TRUSS AND SHEETING ON EACH TRUSS ON BOTH 5100 OF THE BLOCKING -SEE FIGURE 2 ON THIS SHEET. PLUMBING SHALL BE PER FIGURE 1. FLORIDA PLUMBING CODE SHALL BE ADHERED TO. PARTICULAR ATTENTION SHALL BE GIVEN TO PROTECTION AGAINST OVER -PRESSURE AND FREEZING - PER FLORIDA MECHANICAL CODE, CHAPTER 14, AND PER The LeverEft e INSTALLATION INSTRUCTIONS. THIS DRAWING SHOWS THE "W VERSION PLUMBING. HOWEVER, THERE ARE OTHER VARIANTS (PHOTO -VOLTAIC PUMP, INDIRECT, AND/OR DRAIN -BACK) WHICH, ALTHOUGH NOT SPECIFICALLY SHOWN HEREON, ARE COVERED BY THIS SEALED DRAWING -50 LONG AS INSTALLED PER The LeverEdge INSTALLATION INSTRUCTIONS. WATERPROOFING INSTALLER SHALL ADHERE TO REQUIREMENTS OF FBC CHAPTER 15 (ROOFING) AND BEST PRACTICES OF THE NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE THAT THE SOLAR INSTALLATION DOES NOT CAUSE ROOF LEAKS AT INITIAL INSTALLATION OR AS THE SYSTEM "AGES'. QUESTIONS: INSTALLERS, AUTHORITIES HAVING JURISDICTION. OR OTHERS HAVING QUESTIONS OR DIFFERING CONDITIONS• MAY CONTACT THIS ENGINEER DIRECTLY- CELL: 813 650 7246, E-MAIL: AMN@GEZEMIANPE.COM NOTICE TO AHJ, CONTRACTOR,OWNER,&OTHER INTERESTED PARTIES (DIP): THIS PLAN PROVIDES ENGINEER -SEALED DETAILS & SPECIFICATIONS FOR INSTALLATION OF BOTH AE & MORNING STAR CORPORATION (MSC) SOLAR DOMESTIC HOT WATER SYSTEMS. AE & MSC ARE MADE INTHE SAME PLANT BYTHE SAME MANUFACTURER. WHILE TIHEREARE SLIGHT PHYSICAL DIFFERENCES, THESE SYSTEMS ARE EQUIVALENT STRUCTURALLY, HYDRAULICALLY, &THERMALLY. AE DETAILS ARE SHOWN ON THIS PLAN SHEET, BECAUSE AE ISTHE VOLUME LEADER MSC DETAILS MAYBE VIEWED AT; http://W YBetsdar.mm/ ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDO C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 OR PROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT. DESIGN, OPINION. CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC C-700 MAY BE VIEWED AT: HTTP:I/GEZELMANPECOM/REFERENCE/AG/C-700.PDF .. = DIRECT'D'SYS sEM j THIS DRAWING SHOWS The LeverEdge DHW "D'(DIRECT) SYSTEM AND THIS PARTICULAR SYSTEMS PWMBING.THEREARE OTHER, SLIGHTLY DIFFERENT. The LeverEdge DHW SYSTEM VARIANTS WHICH AREALSO COVERED BY THIS SEALED DRAWING. THIS IS BECAUSE THE CRITICAL ELEMENT -THE COLLECTORS) AND ROOF MOUNTING DETAILS REMAIN THE SAME WHETHER The LeverEdge. DHW SYSTEM BEING INSTALLED IS A DIRECr,IN.DIRECTORDRAIN-BACK MODELS WHICH CAN BE CONFIGURED WITH EITHER AN A/C OR PHOTO -VOLTAIC PUMP D/C CONTROLLED ELECTRIC PUMP _ _ _OR `) COLLECTOR SENSOR I . I I I I .. T SOLLAA R LOOP DRAIN ISOLATION VALVE SOLAR LOOP DRAT - EXPANSION TANK MOTORIZED BALL VALV I DIFFERENTIAL CONTROL ET r HOT WATER OUTLET j COLD WATER INLET .;r-.. :,-;. I SHUT OFF VALVE l.•�IlTJ.. BACKUP ELECTRIC ELEMENT 11...•�(,':. STORAGE TANi'::'::fE::IJ. (::::II(. . .:. I'. I TANKSENSO :r.•,..:y }=•R : J m•:n'. TANK DRAIN I FIGURE 1 01 SCALE N i.S LEDGEND 60LA710N VALVE (OPTIONAU. TANK 611P1'LY bTM OFF SOLAR LOOP GRAN (OPRONAU FREEZE PROTECTION VALVE (CPf10NAL.) TB.PEFiAli1RE1PFi�l.FE f8� VALVE PRESSURE Fiat VALVE Ali VENT (OPTIONAL) S •-•� LAOTOf® BILL VALVE ELECIii1C RIsP AC/DC EXPAN890t1 TANG (tDP00NALI SOLAR UNIT (THERMAL OR PV) WIND FORCES GENRAL NOTE: SOLAR UNITS INSTALLED PER THIS PLAN SHALL NOT FORM PART OF THE BUIOING ENVELOPE LIKE WINDOW, DOOR, SKYLIGHT, OR BIPV. SOLAR UNITS SHALL BE MOUNTED ABOVE ROOF SURFACE LIKE AN AC ALL HOT WATER SOLAR COLLECTORS SOLD IN THIS STATE ARE REQUIRED TO HAVE BEEN TESTED BY THE FLORIDA CONDENSER THEREFORE, SOLAR UNITS TAUS INSTALLED DO NOT REQUIRE A PRESSURE DATING AS DO ENVELOPE COMPONENTS SUCH AS WINDOWS. DOORS, & SKYLIGHTS. SOLAR UNITS SHALL BE MOUNTED SOLAR ENERGY -CENTER AND BEAR .ITS CERTIFICATION LABEL. THE COLLECTORS LISTED ONTHIS PLAN COMPLY WI VERYSIOSESO.THE ROOF-SURFACE_7HI5 PROVIDES PRESSURE EQUALIZATION BETWEEN TFIEROOFSURF.iCEA NOTTIEBACKOFTfl ESOlART1NITS THIS RESULTS IN NO SIGNIFICANT CHANGE IN THE LOADS ON THE THOSE REQUIREMENTS. FURTHER INFORMATION MAY BE ACCESSED ON LINE AT: ROOF FRAMING FOR APAItAIIEL MOUNT AND MODEST CHANGES IF TILT UP. HOWEVER,THE INTERNAL UID EXTERNAL COMPONENTS OF WIND PRESSURE DECOUPLE,E.G. THE ROOF RESISTS THE INTERNAL WIND HTTp;//VIWW.FSEC.UCF.EOU/EN/INDUSTRY/TESTING/STCOLLERORS/HOT WATER RATINGS/INOEX.HTM PRESSURES ANDTME SOLAR UNITS RESIST THE ETERNAL WINO PRESSURES. THE E%TERNAL WIND FORCES ARE THEN TRANSFERRED TO THE ROOF FRAMING THRU THE SOLAR ATTACHMENT HARDWARE. WIND CALCULATIONS LINK HERE: HTTP://WWW.GE2ELMANPE.COM/GENERIC/2010fBC_WIND[AL[S.HTM ' NO PZ3 IN HVHZ WH COLLECTORAIM FLAB FWU WWG G� GOB~ rJQ' ROOF PENETRATION 5O GOB NOTE COLLECTORS MAY BE OFiE3rTA V6TIICALLY OR HOR2tDNTALLY MOUNTING BRACKET (BEE DETAIL BELOW N10Wf9 CAN BE ON '.mE9 OR COLLECTOR. ENDS OF COLLECTOR \ I ROOF INSTALLATION DIAGRAM 6(:lLLE: Ni.B. ALL THREAD ROD J BOLT OR LAG MOUNTING BRACKET ALUM TUBE ALUM 7LOE �� LJ�IL PITCH PAN TILE ROOF: CUT OUT RECTANGLE FOR PITCH PAN, J etiLTROR LAG D - INSTALL AND FILL W! 1-PART POURABLE WATER PROOF CONSTRUCTION SEALANT ALTERNATE. TILE ROOF MOUNTING DETAIL Rute4•=,•�• oz FIGURE 2 EVHUES EXPLANATORY INFORMATION ENLARGED NEW LNG & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV)PROVIDES MAGNIFIED VIEWING UP T06400%EV ALSO PROVIDES HYPERLIN.K ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION. EV AMY BE ACCESSED AT MTTP://NRNW.GEZEIMANPE.COM/GENERIC/A5.1.3.WH-lO.PDF I.- . I THERE ARE THREE PROPRIETARY RACK SYSTEMS APPROVED FOR USE WITH THIS PLAN. THESE MAYBE USED TO SUPPLEMENT OR TO REPLACE THE DETAILS SHOWN IN FIGURE 2. IN ALL CASES REFERTO OEM INSTRUCTIONS FOR OE: AILS/SYSTEM BEING USED. IN THE EVENT OF A CONFLICT BETWEEN OEM INSTRUCTIONS AND THIS PLAN, OEM INSTRUCTIONS SHALL PREVAIL OEM MANUALS MAYBE ACCESSED ELECTRONICALLY USING THE FOLLOWING HYPEPLINKS: NTTP://W W W,UNISTRUT.COMAITERATURE/INDEKPHP7DOC=N014&PG+1 HTTP://WWW.IRONRIDGE.COM/FILES/%RS/IRONRIOGE_%RS 1 RAIL SYSTEMADF HTTP://W W W.UNIRAC.COM/PDT/11]2].PDF STRUCTURAL LOADING: THIS PLAN WAS ENGINEERED FOR THE ENTIRE STATE OF FLORIDA INCLUDING HVIQ. 1 THE SOLAR EQUIPMENT REPRESENTED ON THIS PLAN IMPOSES A POSITIVE LOAD UPON THE ROOF STRUCTURE OF LESS THAN 4-PSF. MY UPLIFT PRESSURE CALCULATIONS MAY BE HEWED AT: FITTP://WNAN.GEZELMANPE.COM/GENERIC/2030FBC WIND[ALCS.HTM QUESTIONS REGARDING ROOF PRESSURE ZONES ARE REFERRED TO THE ASCE 10 DIAGRAM FOUND ON PAGE 5 AT THE ABOVE UNIRAC HYPERI.INK. RE 3 FI 03 weNrs ROOF FETTJEiRATKXV AHD FIXStGt2G 2 : PZ =PRESSURE ZONE FRONT ELEVATION -r SECTION A sate v4•=ro• WZ =WIND ZONE SCKE: are'=rm TI FOOT IN EACH I ..... 2-0 20T 4.4 EN TRUSSES Permitting MIDSPAN REINFORCEMENT SHW COLLECTOR MOUNTING BRACKET APPROVED RACKING TWO COLLECTORS MAYBE SYSTEM W/CHANNEL NUT MOUNTED ON 1.25'ALUM. ANGLE EXIST GROG ATTACHED TO BOTTOM FRAME APPRO RACKING 1' OIA SPACER WALL SPANNING BOTH COLLECTORS W/ WATERPROOF SEALANT AND SINGLE SET OF OEM HARDWARE OEM HOLD DOWN: LAGGING (POSITION OVER TRUSS; EXISTING ROOF TRUSS, 3B' LAG BOLT OR TOP CHORD J-BOLT (HOOKS TRUSS) TYP. SHINGLE, MET, FLAT TILE DETAIL. SCPLE: I-VT=1'6 APPROVED RACKING 1' DIA SPACER, LENGTH SYSTEM W/CHANNEL NUT ADNSTRU9IW/TOP OFTLLE EXISTING MEMBRANE 1'DI0.5PACER , LENGTH ADJUST FLUSH W/TOP OF TILE APPROVED RACKING 7. OIA. SPACER W/WATERPROOF SEALANT EXIST. BARREL TILE WHERE APPLICABLE EXISTING ROOF TRU55, OEM MOLD DOWN: FILL CAVITY UNDERTILE TOP CHORD 3LA/B�LAG BOINTERFACE BETWEEN , OTOR OVER TRUS. W/ EXPANSION CONST. FOAM J. BOLT (HOOKS TRUSS) TYP. BARREL TILE ROOF MOUNTING DETAIL SHW COLLECTOR APPLY CONSTR EXISTING ROOF MOUNTING BRACKET ADHESIVE MEDIUM OEM HOLD DOWN: BEAD BOTH SIDES OF LAGGING (POSITION OVER TRUSS) ROOFSHEE NG AND BLOCKIfJG�BETWEEN TRUSSES) RECEIVED D RECTION STARTING ...•.� FING SEALANT FOR WATERPROOFING FROM 'SPANNER' TO WHICH COLLECTOR AUG MOUNT FOOT -PAD IS SECURED BY ALL -THREAD ROD. µ' ng DePa( IN CONE TACTW PLYWOOD St,. LUCIIE COIJI TYP. BEAD OF CONSTR ADHES E%ISTING ROOF TRUSS, TOP CHORD NOTE -THERE SHALL BE AT LEAST 4 HOLD-DOWN ATTACHMENTS FOR EACH SOLAR COLLECTOR ON A ROOF. TYP. MOUNTING DETAIL Rack Mount Flush Mount Standard Mount System• System. System - •RM � � � a 8 iMH MOUNTING BRACKETS scAtE. N.r.s. HINGE MOUNT OEM FURNISHED FASTENER �� 3/8'-16 FINISHED HEX NUT 1/4'-20 X 12' MIX CAP SCREW �y 1 w� 1' x 1' x 0.072' 3/8'-tfi X 4' HIX tT.IANGULAR �? ALUMINUM SQUARETUBE CAPSCREW6 X 13/4'HEXSCREW MOUNTING FI TILT KIT -DECK ANCHOR SCALE NTS BRACKET D2 ELAIE. VNUES I CERTIFY THATTHIS DESIGN & SPECIFICATIONS MEL7THE REQUIREMENTS OF THE CURRENT FLORIDA BUILDING LODE 16502 HPJVNA RD. LUTZ, FLORIDA 3:i549 PH. 813 650 7246 -•%" Arlen@Gezelman PE.COM — �vvnv.GezelmanPEtomr " RAISED OR ELEC '-FRONIC SEAL —� _ I— Y � 2�',4 ":2011 II12 PE. # cAdvice: us Conloct: cAdvim ILK 3603 E Rer,elr Gr TLlmpp 11,33629 0(. 813 979 9154 F1C 666 694 7251 RMIIQCAdv10@.ui %/ wW W.fAdvlCe.uF Lu SYSTEM: 1423 GUNN HIGHWAY oDEssA, FL 33556 REV,0312/12-TM PUBLISHED:04/II9/127:02:55 PrJ THIS IS A SINGLE SHEET PLAN SHEET NAME: PERMIT SET DRAWN:SB CHECKED:AG SHEET NO: A.143-10 1dasN1'3I W w.1 araw--VW_j