HomeMy WebLinkAboutPROPOSED UTILITY STRUCTURE PLANSFBC APPROVED PRODUCTS LIST
SUB CA
STRUCTURAL COMPONENTS ROOF DECK
STRUCTURAL COMPONENTS I STRUCTURAL WALL
EXTERIOR DOORS
EXTERIOR DOORS
FRONT ELEVATION
SCALE: 1/8'.=1,
LEFT SIDE ELEVATION
SCALE: 1l8' =1'
SWINGING
ROLL -UP
MAN
UNION CORRUGATING COMPANY
26 Gauge MasterRib Panel
FABRAL
26 Gauge Grandbeam Panel
26 Gauge MasterRib Panel
ELIXER DOOR AND METAL COMPANY
Series 407
ASTA INDUSTRIES INC.
Model 203
OCCUPANCY GROUP:
U
GENERAL NOTES:
1.
THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM; COMPONENTS AND CLADDING, AND BASE RAILANCHORAGE. OTHER DESIGN
CONSTRUCTION TYPE:
II-B
ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESSIEGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATIONS AND SLOPES, OR OTHER LOCAL ZONING
RISK CATEGORY:
I
APPRE)VAL--
E-QUIREMENTS-ARE-THE-RESPONSIBILITY-OFOTHERS.
No. & DATE
2.
THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE
BUILDING ENCLOSURE TYPE:
ENCLOSED
LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED
WIND EXPOSURE CATEGORY:
C
PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S
RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS.
ULTIMATE WIND SPEED (MPH):
150
FL9555.2-R4
12/12/17
3.
ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
NOMINAL DESIGN WIND SPEED (MPH):
116
FL14081.1-R3
4.
ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
MEAN ROOF HEIGHT (FEET):
14.08
12I13/17
5.
ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14x 1' SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
ROOF ANGLE.(DEGREES):
14.0
_--fL9555T. -R4 --
--6—GONG
_ UNrCUMPRES510E-STRENGTH70F250DPS1-Al 9UAYS7rREREINFORCI RAi3EdU-CON --
-DESIGN PRESSURES`(PSF)t --- --
- — — -----
12/12/17
BE REINFORCED WITH 6X6-W1.4XW1.4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
ROOF:
7.
CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
ZONE 1:
+16.0 / -25.9
FL17996.5-R1
ZONE 2:
+16.0 /.36.5
01/29/18
8.
POST/RAFTER BRACING: 13RACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS.
ZONE 3:
+16.0 /-57.6
9•
i`
SLAB FOUNDATION'SUBGRADE SOILS SN.ALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE, SIXTH EDITION
DESIGN ROOF PRESSURES:
+16;01.29.9
FL8888.1-R5
(2017) - RESIDENTIAL, AND SECTION 16', 1 OF THE FLORIDA BUILDING CODE; SIXTH EDITION (2017) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE
WALLS:
10/07/17
OF 2,000 PSF IS ASSUMED.
ZONE 4:
+26.7 / -29.1
ZONES:
+26.71-32.5
10.
14 GA FRAMING: 2-1/2' x 2-1/2' TUBE STEEL ITS) WITH 2-1/4' x 2=1/$ TS NIPPLES.
DESIGN WALL PRESSURES:
+26.71.29.8
12 GA FRAMING: 2-11,Px 2-1/4' TS WITH 2' x_ 2' TS NIPPLES.
SCANNED
SWINGING DOOR:
+29.91.34.7
BY
ROLL -UP DOOR:.
+28.01.31.1
St. Lucie County
' FTLE.COPY
REAR ELEVATION
SCALE: 1/8'=r' ST LUCIE COUh'Tv
REVIEWED FOR
REVIE _
DATE --?
PLAN t . A D PEF,
N
MUST BE KEPT ON.J
METAL FRAMING AND SIDING PREFABRICATED BY
CARPORTS ANYWHERE
P.O. BOX 776
STARKE, FL 32091
THESE ENGINEERING DRAWINGS ARE THE PROPERTY
OF BECHTOL ENGINEERING & TESTING, INC. AND
CARPORTS ANYWHERE, INC. THESE DRAWING MAY
NOT BE REPRODUCED WITHOUT THE WRITTEN
CONSENT OF BECHTOL ENGINEERING & TESTING, INC.,
AND CARPORTS ANYWHERE, INC.
THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS
HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL
ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION 1609 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017).
THE PLANS ARE.VALID UNTIL THE NEXT REVISION OF THE FLORIDA
BUILDING. CODE:
i
BECHTOL ENGINE G STING; 6.
605 WEST NEW YOROV J= 8
DELAND. FLORIDA 3L%720 ;
Certificate ' ofAuthorIzz0M o,5,4 No,Au
Thomas B tol; P.E. (E"
ox
Florida Lice
PROPOSED UTILITY STRUCTURE
4680 JORGENSEN ROAD
FORT PIERCE, FLORIDA.
0/18
MVSECHT.OL ENGINEEMN6 - . NM .rxe • NOTED
AND '7ES AfA lim .
COKSONG MTWMru, uNeGNUEimw mro WMAIS miING DONMM omaa MKB .. ioain _G1$002
G■�.r°w°"`r„"'°°°°°'°'' - wcwm TB.' ' SHEET 1 OF'3
WELD, CONTINUOUS, ALLSIDES,
TOP AND BOTTOM TRUSS CHORDS
4'
D
. I T 8' 4 14' # 8'
FRONT POST/TRUSSED RAFTER FRAMING PLAN
SCALE: 118' =1'
LEFT SIDE POST/TRUSSED RAFTER FRAMING PLAN
SCALE: 1/8' =1'
CONCRETE:
Concrete Shall Have a Minimum Specified Compressive Strength of2500 PSI at 28 Days.
COVER OVER REINFORCING STEEL
For foundations, minimum concrete cover over reinforcing bars shall be:
3 inches in foundations where the concrete is cast against and permanently in contact with the earth or exposed to the earth
or weather, and 1-1/2 inches elsewhere. Reinforcing bars embedded in grouted cells shall have a minimum clear distance of
114 inch for fine grout or 1/2 inch for coarse grout between reinforcing bars and any face of a cell. Reinforcing bars used in
masonry walls shall have a masonry cover (including grout) of not less than 2 inches for masonry units with face exposed to
earth or weather 1-1/2 inches for masonry units not exposed to earth or weather.
REINFORCING STEEL:
The reinforcing steel shall be minimum Grade 40.
GALVANIZATION:
Metal accessories for use in exterior wall construction and not directly exposed to the weather shall be galvanized in
accordance with ASTM A 153, Class B-2. Metal plate connectors, screws, bolts and nails exposed directly to the weather
shall be stainless steel or hot dipped galvanized.
REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED:
1. All reinforcement is bent cold;
2. The diameter of the bend, measured on the inside of the bar, is not less than sic -bar diameters; and
3. Reinforcement partially embedded in concrete shall not be field bent
EXCEPTION:
Where bending is necessary to align dowel bars with a vertical cell, bars partially embedded in concrete shall be
permitted to be bent at a slope of not more than 1 inch of horizontal displacement to 6 inches of vertical bar length.
26 GA. GALVANIZED METAL ROOF PANELS FASTENED
TO PURLINS WITH (2) #12-14 x 1' SDPs WITH CONTROL
SEAL WASHER @ MAXIMUM S' O.C. SPACING
WELD ALLCHORD
CONNECTIONS,
BOTH SIDES
tN
TYPICAL INTERIOR POST/TRUSSED RAFTER SECTION
SCALE: 118' =1'
26 GA. GALVANIZED METAL WALL PANELS FASTENED
TO POSTS WITH (2) #12-14 x 1' SDPs WITH CONTROL
1' 16 GAUGE FURRING CHANNEL FASTENED TO EACH
RAFTER WITH (2) #12-14 x 3W SELF -DRILLING FASTENER SPACED
NOT MORE THAN 48' O.C.
26 GA. METAL ROOF PANEL
L---TS RAFTER
ROOF PANEL ATTACHMENT
Not To Scale
4'
REAR POST/TRUSSED RAFTER FRAMING PLAN
SCALE: 1/8' = V
■I�I�I�I�I�I�I�I�I�I�I�
0
v
7SIMP
_
RIGHT SIDE POST/TRUSSED RAFTER FRAMING PLAN
SCALE: 1l8' = V
\\�11,111III//��/
H
BECHTOL ENGINEERINt3 E f �1VG•.
605 WEST NEW YORK AVENUIr'
•• Q
�
DELAND, FLORIDA 32720 .� �
Certificate of Auth IN
0 8538
2-1/4' FOR 16 GAUGE U-CHANNEL BRACE
Thomas Bechtol, E.
Florida License No. 38538 �� •• STATE OF .' ,441
12 GA FRAMING FASTENED TO THE POST AND
2-1/2'FOR RAFTER, WITH (2) #12-14 x 31,V
// •'•.F.ORIDP•'��G�
/// SS
14 GA FRAMING SELF -DRILLING SCREWS AT
EACH END (4 PER BRACE)
0
��,, ONAL-
`w \%
BRACE SECTION
Not To Scale
PROPOSED UTILITY STRUCTURE
4680 JORGENSEN ROAD
FORT PIERCE, FLORIDA
4/30/18
M BECHTOL ENG/NEERM o NIM °G1E NITS
AND TES77NG, hm
o MKB `qO1 is G18002
cONSULTNc WNEGHNx'ill. DMONIOUA. Aim NATIMALS Wnxo ENONEE M
°"�,rm°°'"m°°' Gxa u APR O EQ TB SHEET 2 OF 3
TS BOX EAVE RAFTER
MINIMUM 6' LONG TS NIPPLE
NIPPLETO ins'
SECURE WITH (4)#12-14x314'
r
INSTALL 112' x 5-1/2' EXPANSION ANCHOR
THROUGH BASE RA1rWITHINS'OFEAC
RAFTER
E
N4
IMUlul6' LO'4)
SELF -DRILLING FASTENERS
#1 1
SECURE WITH (4) #12-14x 314'
BOW ALONG SIDES OR INSIDE EVERY
48' 16 GA U-CHANNEL BRACE
SELF -DRILLING FASTENERS
TS RAFTER POST (CORNER)
OTHER END WALL POST ALONG END
BRACE ANGLE SHALL BE MIN. 45•
NIPPLETO 3116•
WALL SECTIONS
o TO MAX. 60• FROM HORIZONTAL
BASE RAIL
1-1/2' x 1-1/2' x 2' 16 GA CLIP
E
_ _ _
ANGLE, SECURE TO RAFTER _
E
6'
i POST AND BASE RAIL
MINIMUM 2-1/4' EMBEDMENT
i i WITH (4) #12-14 x 3W SDF's
TS RAFTER POST
, I
GROUND SURFACE
NIPPLETO 3116'
BASE RAIL o TS CONTINUOUS BASE RAIL
\/�\\�� ✓\\//\\�\\,,�\
MINIMUM 6' LONG TS NIPPLE
SECURE RAFTERAND POST
'
-TONIPPL-E-W ITHj4)#12-14x314'-
SELF -DRILLING FASTENERS
°I
TS CONTINUOUS BASE RAIL
MONOLITHIC CONC. FOOTING (2500 PSI MIN.)
TS RAFTER POST
•
REINFORCED WITH 2 #Fs CONTINUOUS
BOX EAVE RAFTER/CORNER POST
RAFTER POST/
'
�� ONCRETE MONO. SLAB BASE RAIL ANCHORAGE
,, CONNECTION DETAIL
BASE RAIL CONNECTION DETAIL
END POST/BASE RAIL CONNECTION DETAIL
Not7o sca e
L Not To Scale
Not To Scale
Not To Scale
TS TRUSSED RAFTER CHORD,
OR NON-STRUCTURAL HEADER
TS POST
OR
TSKFOR
NIPPLE 3/16'
ROLL -UP DOOR FRAME)
D
DBL HEADER
TS RAFTER
2' x 2' x 2' 16 GA ANGLE CLIP
SECURE TO POST AND TOP OF
TS END POST OR DOORI
HEADER, OR BOTTOM OF WINDOW
MINIMUM 6' LONG TS NIPPLE
WINDOW FRAME POST 2'x2'xT 16 GA ANGLE CLIP
RAILIGIRT WITH #12-14 x 3/4' SOFs
••
SECURE EACH WITH (4) #12-14x 314'
TS NON-STRUCTURAL HEADER SECURE TO POST (EACH SIDE) AND
�®
SELF -DRILLING FASTENERS
(12 GA FOR-STRUROLL-UP DOOR FRAME), RAFTER CHORD/RAIL WITH (4) #12-14 x 314'
BASE RAIL, OR WINDOW RAIL SDF's, (2) ON BOTTOM AND (2) ON SIDE
2'xTxT 16 GA ANGLE CLIP
NOTE: AT ROLL -UP DOOR OPENINGS,
TS NON-STRUCTURAL HEADER
SECURE TO POST AND
POST SHOULD BE FLUSH WITH RAIL
(12 GA FOR ROLL -UP DOOR FRAME)
RAFTER WITH #12-14 x 3/4'
END. CLIP POST TO RAIL ONLY ON
SDF's, (2) ON TOP AND
SIDE OPPOSITE THE OPENING.
(2) ON SIDE
L J L J 12 GA TS POST
OR
TS END POST 2'x4' 16 GA PLATE
W RAIL (OR GIRT
SECURE TO EACH SIDE OF
ICAL SIDING OPTION)
POST/RAFTER CONNECTION
WITH (4) #12-14 x 3/4' SDFs,
(2) ON POST, (2) ON RAFTER
POST TO NON-STRUCTURAL HEADER, BASE
NON-STRUCTURAL HEADER OR WINDOW
p DBL HEADER/POST CONNECTION DETAIL
RAIL, OR WINDOW RAIL CONNECTION DETAIL
5
��� RAIL TO POST CONNECTION DETAIL
, END POST/RAFTER CONNECTION DETAIL
$ Not To Scale
V
Not To Scale
� Not To Scale
Not To Scale
3116' WELD, BOTH SIDES, 3116' WELD, CONTINUOUS,
ALL FOUR SIDES, TOP AND
��111111l11�/
\ /
H
•
MINIMUM 6' LONG TS NIPPLE
SECURE EACH WITH(4)#12-14x314'
TOP AND BOTTOM BOTTOM TRUSS CHORDS
(TYPICAL ALL TRUSS POSTS)
\
BECHTOL ENGINEERING A��+' G,
O
TS RAFTER POST
SELF -DRILLING FASTENERS
605 WEST NEW YORK AVENU� O �,� • , 0j i
:.
DELAND, FLORIDA 32720 `
Certificate of Auth tion N _
3g538 •�
0 i
MINIMUM 6' LONG TS NIPPLE
SECURE
12 GA TS POST
TS POST
_ r
WITH (4) #12-14 x 314'
r, SELF -DRILLING FASTENERS
I
LLI
TS CONTINUOUS BASE RAIL
Thomas Becht
Florida License No. 38538 ••• TE OF
12GADBLTSHEADER
°
FLR� OV PCA •'•`•
N
/ •......••
FSS1111111/ONAL
3116' NIPPLE TO
BASE RAIL
3116' NIPPLE TO
BASE RAIL
PROPOSED UTILITY STRUCTURE
4680 JORGENSEN ROAD
RAFTER POST/DBL HEADER
RAFTER POST/BASE
FORT PIERCE, FLORIDA
9 CONNECTION DETAIL
10 RAIL CONNECTION DETAIL
11 TRUSSED RAFTER CENTER CONNECTION DETAIL
�
"M 4/30/18
Not To Scale
°"""x NIM
Not To Scale
Not To Scale
BECHTOL ENGINEERING
W� AND 7ES77N% Ina
""`a NTS
MKB
°"O1 "a G18002
°OMON° cEmECMIC.A.. DMRMmmt. Arm WATMn S TMNG ENMNEM
SHEET 3 OF 3
TB