HomeMy WebLinkAboutPRODUCT APPROVAL 8-22-18Flori''a Building Code Online _ Page I of 2
II 0QS Home Log In i User Registration `• Hot Topics Submit Surcharge Stats & Facts Publications i FBC Staff i BCIS Site Map Unks Search
bird
1 E` 2 g j rn Product Approval ��'++(�%%%���
USER: Public User Chi OL � �®
Product Approval Menu > Rm c[ or Applfcagon Search > Apiiq n Ust > Application Detail
i
FL #
FL2569-1114
Application Type
Revision
RECEIVE
Code Version
2017
Application Status
Approved
AUGn 2. 2018
Comments
ST. LucileJ1C]ounty, Permitting
Archived
Product Manufacturer
Soprema, Inc. (Canada)
Address/Phone/Email
1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
memathieu@soprema. ca
Authorized Signature Marc -Etienne Mathieu
memathieu@soprema. ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative Jean -Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
!._ Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Robert J. M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich, PE
i Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R14 COI 2018 01 COI NIEMINEN.pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D4798
2011
ASTM D6163
2008
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
UL1897
2012
VAff
n•;L If
)://www_floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB IO... 4/20/2018
Flori' !a Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary roducts
Method 1 Option D
02/12/2018
02/14/2018
02/17/2018
04/10/2018
Page 2 of 2
FL #
Model, Number or
Description
Flame
2569.1
Soprema Roof
Self adhering roof underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R14 1%2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
R14_pAf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for
Evaluation Reports
Limits of Use. 2.) The design pressure
EL2569 R14 AE 201802 FINAL ER SOPREMA CA UNDER R. YMEN S FL2569-
Ridf
noted herein pertains to underlayment
systems used beneath adhesive -set the
Created by Independent Third Party: Yes
systems. Refer to ER Section 5.6.4 for
details.
i N__
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: SSOr487-IS24
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if
they have one. The emalis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
El
Credit Card
Safe
/www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB10..., 4/20/2018
ENGINEER EVALUATE TEST
?ma, Inc.
rue Haggerty
mondville, Qu6becJ2C 5138 Canada
478-2400
Certificate of Authorization N32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
CONSULT CERTIFY
Evaluation Report S18010.06.09-1112
FL2569-R14
Date of Issuance: 06/15/2009
Revision 12: 02/12/2018
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
co �struction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
pr ducts described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
se !tions noted herein.
D IIE,SCRIPTION: Soprema Roof Underlayments
EUNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
"eln.
NTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
ality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
s Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of
s Evaluation Report relative to updated Code requirements with each Code Cycle.
VERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
iertising literature. If any portion of the Evaluation. Report is displayed, then it shall be done in its entirety.
PECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
distributors and shall be available for inspection at the job site at the request of the Building Official.
Evaluation Report consists of pages 1 through 8.
eared by:
art J.M. Nieminen ' P.E.
': c ter..; ,_= The facsimile seal appearing was authorized by Robert
to Registration No. 59166 Florida DC4ANE1983
Nleminen, P.E. on 02/12/2018. This does notserve as an
-��•�•nn! "' electronically signed document
IFICATION OF INDEPENDENCE:
NEMO ETC, LLC does not have, nor does It intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates. ,
MEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
S"NEM0
etCe
�Roo�
FING COMPONENT EVALUATION:
Y .^?� .Y V".ba'a :;r A t?"i ...k � ..{�„ .I�C'g zh P;u'rw�,y 1 ux'2" - 1^•'�... ��C-. .:i�'�'. .'•.rhvms..i" £ f.�' � � ,.
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 6th
Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions
of Use set forth
herein.
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
FRSA/TRI April 2012 (04-12)
Physical Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
ASTM D4798
2011
,tom. �,e_. _ �,
� `�'. , -« T"�•.. �'�«r�:rt T�`"r
Enti
Examination
Reference
Date
ERD (TST6049)
ASTM D1970 / TAS 110
2968.05.04-2
05/14/2004
ERD (TST6049)
Physical Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 / TAS 110
2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance
2779.11.05-R1
04/18/2007
ERD (TST6049)
TAS 103 / TAS 110
S7120.11.07-2
11/02/2007
ERD (TST6049)
ASTM D1970 / TAS 110
513190.02.09-131
04/01/2010
ERD (TST6049)
ASTM D1970 / TAS 110
531370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.10-R1
09/09/2010
ERD (TST6049)
Physical Properties /Tensile Adhesion
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties / Tensile Adhesion
S43530.02.14-1
02/21/2014
ERD (TST6049)
Physical Properties / Tensile Adhesion
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.14
04/17/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-D (CER1592),
HVHZ Compliance
15-0508.04
09/24/2015
[CC -ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
PRI (TST5878)
Physical Properties
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
1 Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths; 36 and 45 inch; meets ASTM D1970.
3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven 'polyethylene surfaced, SBS modified bitumen roof
underlayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970.
4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
ETC, LLC Evaluation Report 518010.06.09-1112
to of Authorizatlon #32455 6" EDITION (2017) FBC NON.HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 2 of 9
1
.4
y
9
Lastobond Pro HT-N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths; 36 and 45 inch; meets ASTM D1970.
Lastobond Pro HT-S is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
EnviroShield is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment; meets ASTM D1970.
Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
Lastobond Smooth Seal HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970.
RESISTO LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width; meets ASTM D1970.
PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
RESISTO LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment,
with a 44-inch sheet width; meets ASTM D1970.
Colphene FIR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Fire Classification. is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
Allowable Roof Covers:
,: v..,
' a ® ®
�Mgl�
.,ter•,
r:
a z ..Rwaa t i%�wSa va
a Na , x rn`
Wood or
Slate or
Underlayment
Asphalt
Nail -On
Foam -On
Metal
Composite
Composite
Shingles
Tile
Tile
Shakes &
Slate
Shingles
LastobondTU HT
- Yes
Yes "
Yes
. Yes'-
Yes•
Yes
See551,
Lastobond Shield / Pro HT-N /
Yes
No
No
No : _
Yes`
Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT / Pro HT-S
Yes. ,
No
No
Yes.;
Yes-
Yes
EnviroShield
Yes
No, •
._ No :.
Yes :
Yes.
Yes
ETC, LLC
ite of Authorization ti32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION
Soprema Roof Underlayments
Evaluation Report 518010.06.09-1112
FL2569-R14
Revision 12: 02/12/2018
Page 3 of 8
E O etc.
"yiit
Wood or
Slate or
Asphalt
Nail -On
Foam -On
Metal
Composite
Composite
Underlayment
Shingles
Tile
Tile
Shakes &
Shingles
Slate
Lastobond Eaves Protection Sheet /
Yes
No
No
No. •
Yes ..
Yes", -
Lastobond 195
Lastobond ECO / RESISTO LB1236,
Grip Rite Eave &Valley Protector /
Yes
No
No
=No.
Yes-'
:Yes.
RESISTO LB1244
y
Lastobond Smooth Seai HT
Y.es
No
No.
Yes
Yes .,.
Yes
Yes.
Yes
Yes
No
:Yes
Yes
Colphene FR GR
See 5.5.1
.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
Adhesive
Florida Product Approval
Underlavments.
Dow TileBondTM'
FL22525
Lastobond TU HT
ICP Adhesives PolysetO AH-160
FL6332
Lastobond TU HT or Colphene FR GR
6 Allowable Substrates.
6.1 Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO L61244 or Lastobond Smooth Seal HT applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.
N ote:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming
with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of
the self -adhering underlayment.
.2 Bond-to-Irisulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO L61244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on
tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional
and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D,
Testing Application Standard TAS 114, Appendix J or UL1807.
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product ApprovalforOverturning Moment Resistance Performance.
ETC, LLC Evaluation Report 518010.06.09-R72
ite of Authodzotlon #32455 6' EDITION (2017) FSC NOrl-HVHZ EVALUA T 10N FL2569-R14
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 4 of 8
t
1 N EMO- J etc.
Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT -IV, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ ASTM D226, Type I or II felt; Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems (Lastobond TU FIT only), base layer shall be
attached in accordance with FRSA/TRI April 2012 (04-12).
Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol600c
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
#3 Maximum Design Pressure = -150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or weighted
roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -
laps.
#4 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC
1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced' rows
in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered
.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on the systems carry a Maximum
Design Pressure of-45 psf.
ETC, LLC Evaluation Report 518010.06.09-1112
ate ofAuthorirotion #31455 6' EDITION (2017) rSC NON-HVHZ EVALUATION FL2569-1114
soprema Roof Underlayments Revision 12: 02/12/2018
Page 5 of 9
For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.
Assemblies marked with an asterisk's carry the limitations set forth in Section.2.2.10.1 of FM Loss Prevention
Data Sheet 1-29.(January 2016) for Zone 2/3 enhancements.
Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236,
Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after
installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-
S, EnviroShield shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FIR GR shall not be left exposed for longer than 180-days after installation.
Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
7,.t=I.�C:4jA.I?„°p.n.�.1:,35
Maximum
Underlayment
Tile Profile
Staging Method
Slope
Flat
Max. 10 the stack
6:12
Lugged
Max. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high
6:12
on slope, as shown below)
LastobondTU HT
r ��
Lugged
S
.1
Flat
Max. 10-tile stack
5:12
FColphene FR GR
Lugged
Max. 10-tile stack
6:12
ETC, LLC Evaluation Report S18010.06.09-1112
ite of Authorization #32455 6" EDITION (2017) FBC NON-HVHZ EVALUA T 10N FL2569-1114
Soprema Roof Underlayments Revision 12, 02/12/2018
Page 6 of 8
Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or
RESISTO EXTERIOR PRIMER (if applicable).
Lastobond TU,HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HTT S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth -Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Colphene FIR GR:
1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
2 Non Tile Applications:
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR
PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of
release film.
Adhere the exposed part tolthe substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed
using either heat -welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of the
sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction.
For valleys, apply the sheet starting at the lowest point and work upward.
3 Tile Applications (Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall
outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 2 herein, and Soprema published requirements for tile staging.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
ETC, LLC Evaluation Report S18010.06.09-R32
de of Authorization #32455 6TE EDITION (2017) FBC NON-HVHZ EVALUATION! FL2569-R14
Soprema Roof Underlayments Revision 12: 02/12/2019
Page 7 of 8
Contact the noted QA agency for information on product locations covered for F.A.C. 610320-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant
Specification
Product(s)
Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-N, Lastobond Pro HT-S, EnviroShield, Lastobond 195,
Drummondville,
ASTM D1970
Lastobond Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth
QC (Canada)
Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley
Protector, RESISTO LB1244
ASTM D1970 & FRSA/TRI 04-12
Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Wadsworth, OH
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
ASTM D1970 & FRSA/TRI 04-12
Lastobond TU HT; Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Gulfport, MS
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
ETC, LLC Evaluation Report S18010.06.09-1112
to oJAuthorizotion N32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12: 02/12/2018
Page 8 of 8