HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING1
SCIS Home I Log In j User Registration ; Hot Topic Submit Surcharge Stats & Fads Publications FBC Staff ! BCIS Site Map' i Unks i Search
'Product Approval
USER: Public User
1203
ProductAooroval Menu > Product or Aoolication Search > Aoolication List > Application Detail ST. LUCI E COUNTY
BUILDING DIVISIO
FL # FL17022-R7 "`�"
Application Type Revision FOR COMPL
REVIEWED B
Code Version 2017 DATE
Application Status Approved PLANS AND PERMIT
MUST BE KEPT ON JOB OR
Comments 08/18/2017v. date reapply 08/2,417 NO INSPECTION WILL BE MADE--
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive THESE PLANS AND ALL PROPOSED WORK
Palm City, FL 34990 (772)872-8034 ARE SUBJECT TO ANY CORRECTIONS
flvalidation@yahoo.cam REQUIRED BY PIU WSPECTORS MAT
WAY DE NECESSARY IN ORDER TO
Authorized Signature Richard McKuhen flvalidation@yahoo.com COMPLYWITH ALL APPLICA CODES .i
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive CONCFAED FASTENERS OR ATTACHMENTS
Palm City, FL 34990
(772) 872-8034 ARE THE RESPONSIBIM OF THE
rchard@emfab.net CONTRACTOR OF RECORD
Quality Assurance Representative
Address/Phone/Email SG nN NFED
Category Roofing dBy
�},,�
Subcategory Metal Roofing St. Lucie County
''oo ountV
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
UL 580
Year
2003
2012
2006
Equivalence of Product Standards r ��
Certified By
Sections from the Code
..F
/pdpr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d
1/4
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Snmmnry of Prnriurtc
Method 1 Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (116)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (116)
0.032" Aluminum, 318" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. InstaII the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odF
Created by Independent Third Party: Yes
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3
3 - "1.5" Mechanical Seam" (R5)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
!
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24oa ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL i
installation method listed in this report and applicable code
seam 24oa ssr.odf
sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 U FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
installation method listed in this report and applicable code
ALUMINUM ssr.odf
sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.5
5 - "1 in. Nail Strip" (R5)
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr Ddf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
EVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 214
Design Pressure: +N/A/-Tahlp A Evaluation Reports,
Other: Refer to evaluation" 'Irt for conditions and FL17022 R7 AE° `17022.5 1.0 NAILSTRIP ssr.pdf
limitations of use. Install thi,_._ �oembly in compliance with the Created by Indej • _ _ Int Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.6
6 - "1 in. Nail Strip" (115)
1" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 H FL 17022.6 1.0 NAIL STRIP 0,032
ALUM ssr.odf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.pdf
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.7
7 - "1.5 in. Nail Strip" (115)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr Ddf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.odf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.8 18
- "EMAX Rib" (115)
29 gauge steel, lapped roof panel mechanically attached to
i
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 177022.8 EMAX Rib ssr pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 177022.8 EMAX Rib ssr.odf
limitations of use. Install the assembly in compliance with the
Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
i
17022.9 9 - " PBR MAX" (115)
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.9 PBR RIB ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Design Pressure: +N/A/ A
Created by Independent Third Party: Yes
-Table
Evaluation Reports
I Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.9 PBR RIB ssr.odf
limitations of use. Install the assembly in compliance with the
Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
Plext
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail bo this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determinA if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
ON WE _chat 13
3/4
Palm City, FL 34990
Complilal nt with Florida Building Code 2017 (6t�' ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Produ41. 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosi n Resistant Compliant: FBC Sec.1507.4.3
Fastene�; 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" mlljn. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements) .
Fastene� 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetra a 3/161,min. thru deck or 5/8"embedment into wood plank. (*or sufficient length
to meet requirements)
Underla 'Iment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Det�lls: Table A Allowable Loads
METHOD 1.
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPAdNG
16" ox.
16" ox.
8" O.C.
6" o.c.
FASTENER " PACING (ALONG Panel width)
12" ox.
12" ox.
12" ox.
12" ox.
FASTENEk$IZE
#9
#10
#10
#10
Reference
Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
!UL580-06
1897-041 Test Report IMS93.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-0
Test Report D05893.02-450-18 07/22/14
*E UIVALE
Q l�l
CY-UL 1897-04 is Design pressure margin of safety 2;1
equivalent to test standard UL 1897-1�I
l rff
Locke Bowde
', P.E. does not have, not will acquire a financial in` 111 distributing
under this eva
�r cg rlyin0%facturing or products
uation. �.
Locke Bowde
P.E. is not owned, operated, or controlled by aQy coAparflrvm3 96A;turem, or distributing products under this
report.
' ��4,fS
r Tt
l
t
.imitations:
1. Underlayi
2. Minimum
3. Products
4. Engineeri
5. Fire class
6. Support fi
Structural
7. This repot
FL17022.1 5V ir,- r y np (26GA Steel), 24"' Wide Roof El-o�el -Details
nt to be compliance with current Florida Building Code (FBC)2017 6t' ed.
ipe to be compliant with Florida Building Code 2017 6"' ed., and per with Manufacturer's installation reference.
compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
analysis for "project specific approval by local authorities wrurisdiction is allowed by other registered engineers.
ation is not part of this acceptance. Shear diaphragm values are outside this report.
ling in compliance w/FBC 2017 6"' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
not imply warranty, installation, recommended product use outside of this report.
30
i
24-
dW 1T
oPrromAL s mTlcws
Panel Profile
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
X 1-1/2" Min. or #10 x 1-1/2" Min. per
—fable "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
-Wood plank
Credit Card -
Safe
4/4