PRODUCT APPROVAL
0 True PowerTm Electrical Technology Two Line LCD Multilingual Digital Evolution""' Controller (English/Spanish/ French/Portuguese) Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. Electronic Governor System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* FEATURES GENERAC 0 GU I ROIAN° SERIES SCANNED ResidentiJl Standby Generators BY Air -Cooled Gas Engine St. LucieCounty Models G007036-0, G007037-0 (Alu Model G007035-0 (Alu Models G007039-0,.G007038-0 (Alu Models G007043-1, G007042-1 (Alu O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTiNG are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times In high temperatures and extreme operating conditions. O TRUE POWER', ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: J PROTOTYPE TESTED V NEMA MG1.22 EVALUATION d SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY 9 c uiL us OC LISTED Note: CUL certification on limited circuit switches. U the USA only. *Only if located away and unless otherwise SOLID-5?1YTE, FREQUENCY This state-of-the-art power n all Generac models. It provid load conditions and MAXIf eledtronically torque-matchi voltage regulation at ±1 %. SINGLE SOURCE SERVICE network provides parts and st engine to the smallest electro Standby Power Rating num - Bisque) -16 kW 60 I-Iz num - Bisque) -16 kW 60 Hz num - Bisque) - 20 kW 60 I-Iz num - Bisque) - 22 kW 60 Hz to unbundled units and units packaged with god with the Smart Switch are UL certified in and fresh air Intakes, jMFENSAiE0 VOLTAGE REGULATiON: mining regulation system Is standard on optimized FAST RESPONSE to changing M MOTOR STARTING CAPABILITY by the surge loads to the engine. Digital WONSE from Generac's extensive dealer ;e know-how for the entire unit, from the component. O GENERAC TRANSFER 3 " iTCHES: Long life and reliability are synonymous with GENERAC� POWER SYSTEMS. One reason for this confidence is that the GENE AC product line includes its own transfer systems and controls for total! system compatibility. w G E N E R A C ryat�•3ss ; ,���4A PROMISE zoos• -Im la mu." vIM00omaaVa aa0larolgn pMf. 1 I \ �3ENERAC" benefits 16/ �0/22 kW feo tures and Engin .I • G( G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma moly rings helps the engine nerac run cooler, reducing oil consumption resulting in longer engine life. • "piny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • EI lctronic ignition/spark advance These features combine to assure smooth, quick starting every time. • F 'I I pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less mainten nce and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • L w oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Bert rator • F evolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revo ving armature generator. • kewed stator Produces a smooth output waveform for compatibility with electronic equipment. • I laced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • 1 IL 2200 listed For your safety. I rare Iter Switch able) • ully automatic Transfers your vital electrical loads to the energized source of power, • EMA 311 Can be installed inside or outside for maximum flexibility. • iemote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evo • !,Z!cr A.Ianlrais Illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in an condition. • tto/Manual/Off o-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • ,i hlity voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to thh home. • JG.enerator Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the t ctory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • 'Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation provl ilng flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdo r air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency, U i • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- Ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent Injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 1811 away from a bulldini 1. Ills allation System • 1 it (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system, 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolo 1ging engine life. GENERAL 1 /20/22 kW specifications E-7c6:Ci fgk©P 0007035-0, 6007036.0, G00703810, G007039.0 G007042.1, G007043.1 Mo all 0007037.0 (16 kW) (20 kW) (22 kW) RatMaximum Continuous Power Capacity (LP) 16,000 Watts' 20,000 Walls" 22,000 Rad Maximum Continuous Power Capacity (NO) 16,00 QWatts` 18,0b gOWails. 19,500 , 00 Aa Voltage Rated Maximum Continuous Load Current — 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 To I 1 Harmonic Dislortibn Less than 5% Lei 1�o 5% Lets than5% M Line Circuit Breaker 70 Amp 0 An P p Ph 'se 1 1 1 Nu 1 bar of Rotor Poles 2 2 2 Ra ed AC Frequency 60 Hz 60 Hz 6OHz Po'or Factor 1.0 Be ery Requirement (not included) 12 Volts, Group 26R 54Q, CCA Mini 1.0 1.0 Turn or Group 35AGM 650 CCA Minimum U It Weight (lb/kg) 406/186 4148/203 466/211 Di ensions (L x W x H) In/mm 48 x 25 x 291218 x 638 x 732 S and output in dB(A) at 23 R (7 m) with generator operating at normal load** 66 66 67 S and output in dB(A) at 23 it (7 m) with generator in Quiet -Test'" low -speed exercise mode"" 58 58 58 ercise duration 5 min 5 min 5 min P, gl'le2 TT1 pit of Engine GENERAL G Force 1000 Series N imber of Cylinders 2 1 2 2 D spiacement 999 cc 399 cc 999 cc C fibular Block Aluminum / Cast Iron Sleeve V Iva Arrangement Overhead Valve Ove head Valve Overhead Valve I onion System Solid-state w/ Magneto Solld-stale w/ Magneto Solid-state w/ Magneto Ivemor System Electronic Electronic Electronic ompression Ratio 9,5:1 9.5:1 9,5:1 Starter12 Vdc 12 Vdc 12 Vdc dil Capacity Including Filter Approx 1.9 gV1.8 L Appro 1.9 gl/1.8 L Approx.1.9 gt/1.8 L dpporating rpm 3,600 3.600 3,600 Friel Cansumillion atural Gas ft3/hr (m3/hr) 1/2 Load 218 (6.17) 2)4(5.78) 228 (6.46) Full Load 309 (8.75) 3 1 (8.52) 327 (9.26) quid Propane ft3/hr (galthr) [Vhr] 1/2 Load 91.6 (2.52) [9.53] 86 ( .37) (8.99] 92 (2.53) [9,57] Full Load 106.8 (2.94) [11.11] 129.6 (3.56) [13.481 142 (3.90) (14.771 tdole: Fuel pipe must be sized for lull load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7°water column (7-13 mm mercury) for natural gas, 10-12" water column (19-22 mm mercury) rtir UP gas. For Btu content, multi Iy It3/hr x 2500 (LP or flaAr x 1000 (NG . For Mega)oule content, multiply ma/hr x 93.15 (LP) or maPor x 37.26 (NG) Line Plain Text Multilingual LCD Display Simple user Inteti ace for ease of operation. ode Bultons:Aulb Automatic Start on L Illily failure. 7 day exerciser, anual Start with starter control, unit slays on. If utility fails• transfer to load takes place. If Stops unit. Power is removed. Control and charger stilt operate. eady to Run/Maintenance Messages tandard ngine Run Hours Indication $landard rogrammable start delay between 2-1500 seconds Standard (progr mettle by dealer only) lility Voltage Loss/Retum to Utility Adjustable (Brownout Setting) From 140 171 V/190-216 V iulure Set Capable Fxerefser/Exercise Set Error Warning itandard uniAlarm/Malntenance Logs 50 vents Each Engine Start Sequence Cyclic cranking:16 sec on. 7 rest (90 sec maximum duration). tarter Lock -out Starter cannot re-engage u All 5 sec after engine has slopped. mart Battery Charger tandard he rger Faulf/Missing AC Warning tandard how Battery/Battery Problem Protection and Battery Condition Indication ;tandard utomalic Voltage Regulation with Over and Under Voltage Protection Standard nder-Frequency/Overload/Stepper Overcurrenl Protection Plandard y afetFusid/Fuse Problem Protection Standard [Automatic Low Oil Pressure/High Oil Temperature Shutdown �Iandard OvercranlVOyerspeed (@ 72 Hz)/rpm Sense Loss Shutdown 15 Standard , Igh Engine Temperature Shutdown Standard Internal FaullAncorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard —Sound levels are Taken from the rmnlof the generator, Sound levels taken from other sides of the generator may be higher depending on Installation parameters. Rating delinitions- Stand by: Applicable for supplying emergency power for the duration of the utility power outage, No overload capability Is available for thi's rating. (All ratings in accordance with DS5514.1803046 and DING271). ' MWmum Movolt amps and current ard subject to and limited by such factors as fuel Blulimagajoule content, ambient lemperatme, altitude, engine powerand condition, etc. Maximum power decreasesaboul3.5percenlfofeach 1,000 feet (304.8 meters) above sea level; and alsowill decrOaabbut 1 percent for each 6 °C (10 °F) above 16'C (60'F). Automatic Transfer Switches • GENERAL' Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase C @ us LISTED *CUL only applies to non -service rated switches Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'"' or NexusT"" Co troller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non lservice equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. ndard Features SeMce rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 311 enclosure*, with elei �trostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for ye �s of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All swi ches are covered by a 5 year limited warranty. * Non -service rated (RXSC) switches are housed in a steel enclosure. 0 'M Technology )ugh the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC trolled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be iaged as well, providing the most installation efficient power management options available. So 9007: GENERAC® 10�0-400 Amps, Single Phase Automatic Smart Transfer Switches Fu ctioas All ti iing and sensing functions originate in the generator controller ,Utilityvoltage drop-out......................................................................................................................................................................................................................<65% Timer to generator start ..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer" Enginewarm up delay.................................................................................................................................................................................................................5 seconds Standbyvoltage sensor..................................................................................................................................................................................................65% for 5 seconds Utilityvoltage pickup.........................................................................................................................................................................................................................>80% �Re-transfer time delay...............................................................................................................................................................................................................15 seconds EEnginecool -down timer............................................................................................................................................................................................................60 seconds xerciser..............................................................................................................................................................5 or 12 minutes adjustable weekly/Bi-weekly/Monthly.. ,line transfer switch can be operated manually without power applied. used in conjunction with units utilizing Evolution" controls "Adjustable via the controller Spocificadions Mod ' RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW20OA3 RXSW300A3 RXSC400A3 RXSW400A3 Amp 100 100 150 200 200 300 400 400 Volta .e 120/240, ie 120/240,1e 120/240, is 120/240, ie 120/240,1a 120/240, ie 120/240, ie 120/240, ie Load ransitian Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition L Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Encic sure Type NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R UL Ring UUCUL UL UL UUCUL UL UL UL/CUL UL With (Amp) land Rating 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug I ange I 1/0 - #14 250 MGM - #6 600 MGM - #4 or 1/0 - 250 MGM 111 lodel RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 RXSW300A3 RXSC400A3 RXSW400A3 Heig H1 t 17.24/437,9 17.24/437.9 26.751679.4 17.24/437.9 26.75/679.4 42.9111089.9 31.25/793.8 42.91/1089.9 (In./m ) H2 20/508 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 48/1219.2 NOW1 1 12.51317.5 12,5/317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 (in./m ) W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 0epl (In./trim) 7.09/180.1 7.09/160.1 6.3/160.1 7.09/180.1 6.3/160.1 10.06/255.5 10.06/255.5 10.a6/255.5 Weigh I(IbsJkilos):20KO7r225,�21 i 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 DEPTH DEPTH GPN E RAC° Generac Power Systems, Inc, • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com IF02017 Generac Power Systems, Inc. All rights reserved. All specilicatians are subject to change without notice. Bulletin 16000013459-A 04/24/17 1 b/ GEIliERAC h ZWZZ KIN available accessories Mo el # Product Description -The WI-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon- G00 0 Wi-Fi LP Fuel Level Monitor Itoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an ,005 unexpected powerfallure. Status alerts are available through a free application to notify when your LP tank Is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G00 463-4 Mobile Link'" cess to an Internet connection from a PC orwith any smart device. You will even be notified via a -mall or text message when a change in the generator's status occurs. Available in the U.S. only. 000 819-0 26R Wet Cell Battery Every standby generator requires a battery to startthe system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact@). G00 101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). G00 Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 102-0 Oil Warmer O,F G00 621.0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a GOO I027-0 - Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodents and Insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, It is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit Includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase its (50 Amps) power management capabilities. it provides additional power management flexibility not found in any other power management system. dimensions & UPCs Dimensions shown are approximate. Refer to Installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. BBB LE" sloe VIEW L! `~ pa.s lm FRONT VIPW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 N E RAC® Generac Power Systems, Inc. - S45 W29290 HWY. 59, Waukesha, WI 53189 - generac.com samnzs�' w { ©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No.10000000194•F 613117 LJ 'earl Management Modules (SMM) GENERAC® ACCESSORIES Model G006878-0 C@Us Us:m 1CRIPTION Ra's Smart Power Management System Is designed to optimize the performance of a standby generator. The system can consist of up to 8 Individual Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self - and operate autonomously. Y Is the true measure of generator engine performance and does not need to factor In Increased ambient temperatures, elevation changes or fuel type. The modules monitor the frequency (Hz) of the power being produced by Qenerac's standby generators and It It falls below a certain the module will automatically folloW a polder management algorithm to ensure that the generator is not overloaded. The �odules can be set to a load priority between 1-8 or be set In a lock out only mode for loads that just simply do not need to run In an outage, therefore reduping the necessary size of the generator for a more cost eflective solution. 89 IM SPECIFICATIONS — PowsSupply Saome... ...».»............................................ ......... .......... »..................................................... Supp Fled Voltages .... ............. »..»............................................ ;........... ........................................................»..........»............................................. 240 VAC (from U24 Input) Conor CWI Vcttege..».............................................................,......................,.............................................,...................................» ..240 VAC Collc In coll.........»...............».»....._.».......»...................»»_.......»........................................................................................»..............................................................240 VAC coilV Sealed....................................................................».......................................................:.............................................................................................» ......... ».......... 30 Poles'.............................................................................................................................................................................................»....».........,.................»..............................., 62 » Restsire Amps..».................................................................................................................................................................................................................................................... so F/LIn uctiveAmps................................ .................... .............. I........... »........................ Loc RotorAmps........................................................................................................ .....................»..........................»................................................... ... 40 ............ UI50............................................................... . Yes Enclo ure Rating .............. ».......... ...... ................... ................... ....... ...........................;..................... ...y........ _............................................ ............................,.............. .............. NEMA SR GENERAU " BENERACO Management Modules Dlm®nslnns and DISC Model GOOfi M Height OP/MM) Hi H2 6.17/156.8 2.300 YAM OWM) W1 W2 7.081179.4 4.72/120 WNW) 8.7/94 Weight {Ibs/Idlos) 2.0610.94 Shipping WetgM O Wios) 2.4411.11 UPC Code 698471068733 Controls (located behind the cover of the module) s ! LED ON=LOAD OOMMOTAD LEO FLASHiS a LOAD SHED LOOKOUT LOOKOUT PRIORITY LO LED FLASH 38=0MIN LOOKOUT GENERATOR LED FLASH 68= GM LOAD LOOKOUT 3 7 �^ LEOOFF=NOMGDOLEPOWER ® -� (0 0 LOOKOUT TEST DISABLED Priority Diet (A) — Sets module priority. Lockout Switch (B) — Pravanis load from operating when system Is operating under generator power, Test Butlon (C) — Disablss contactor output for a specified tlms. ID) _ Provides module slalus vdth easyvjewing through the external viewing window LED Coated in the upperrIght comer of the module, Generac Power Systems, Inc. a S45 W29290 HWY. 59, Waukesha, WI 53189 a gEnerao,cOM 02016 Generas Parlor systems, lno. All rigllle reserved. Builenn OL16OM MINAS Site Selection and Prep>arafion 3: Sife Selection and Preparation Selection i 5 It (1.62 m) ; ti , 3 ft B O ¢'(0,91 rn) 3ft(0.91 m) IBp�� ' Figure 3-1. Installation Cleamnees ID Description Comments A Top of generator — B Front and end clearance Minimum clear distances cannot include shrubs, bushes, or trees. l C Rear clearance '18In (48.7 cm) minlmum clearance per NFPA teagny, labeling, and listing, unless state or local codes dictate otherwise. D j Windows and openings No operable windows, doors, or openings In the wall are permitted within 6 ft (1.62 m) from any point of the generator. E Edsting wall One -hour fire rated watts allow closer placement of the generator set. Confirm before Installation. F Removable fence Removable fence panels for servicing cannot be placed less than 3 ft (0.91 m) In front of the generetor. G Overhead clearance 5 ft (1.62 in) minimum distance from any structure, overhang, or projections from the wall. DO HOT install under wooden decks or structures unless this distance Is maintained. Guidelines For 60 Hz Air -Cooled Generators 11 Selection and Prepar; '� t all the generator set, In Its protective enclosure, faors where adequate cooling and ventilating air is Iys available (.Tgn a 2- ). Consider these factors: The installation of the generator must comply strictly with 1CC 1FGC, NFPA 37, NFPA 54, NFPA 58, and NFPA 70 standards. install the unit where air inlet and outlet openings Will not become obstructed by leaves, grass, snow, etc, if prevailing winds will cause blowing or drifting, consider using a windbreak to protect the unit. Install the generator on high ground where water levels will not rise and endanger it. This unit should not operate In or be subjected to standing water. Allow sufficient room on all sides of the generator for maintenance and servicing. This unit must be Installed In accordance with any local, state, or national codes for minimum distances from other structures. Clearance from the ends and front of the generator must be 3 ft (0.91 m). This includes shrubs, bushes, and trees, Clearance from the back of the generator must be at minimum of 18 In (457 mm). Clearance at the top should be a minimum of 5 ft (1.52 m) from any structure, overhang, or protections from the wall. DO NOT Install under wooden decks or structures unless there Is at least 5 ft (1.62 m) of clearance above the generator, Install the unit where rain gutter down spouts, roof run-off, landscape Irrigation, water sprinklers, or SUMP pump discharge does not flood the unit or spray the enclosure, Including any air inlet or outlet ° install the unit where services will. not be affected for obstructed, including concealed, underground, or covered services such as electrical, fuel, phone, air conditioning, or irrigation. This could affect inlarranty coverage, ere strong prevailing winds blow from one fiction, face the generator air inlet openings to Prevailing winds. all the generator as close as possible to the fuel oly to reduce the length of piping. REMEMBER ►T LAWS OR CODES MAY REGULATE THE rANCE AND LOCATION. In the absence of i codes regarding placement or clearance, we mmend following these guidelines: install the generator as close as possible to the transfer switch. REMEMBER THAT LAWS OR CODES MAY REGULATE THE DISTANCE AND LOCATION. — The generator must be installed on a level sur- face. The generator must be level within a 0.5 In (13 mm) all around. — The generator is typically placed on pea gravel, compacted soil, crushed stone, or a concrete Pad. Check local codes to see what type is required. if a concrete pad is required, all appli- cable codes should be followed. Installation Guidelines for Stationary Air -Cooled Generators NFPA 37 is the The National Fire Protection Assoclatlon's standard for the installation and use of stationary combustion engines. Its requirements limit the spacing of an enclosed generator set from a structure or wall NFPA 37, Section 4.1.4, Engines LoGatsd OUtd00rS: Engines, and their Weatherproof housings if provided, that are Installed outdoors shall be located at least 5 ft 0.52 m) from openings In walls and at least 5 ft (1.52 m) from structures having combustible wails. A minimum separation shall not be required where the following conditions exist. 1. The adjacent wail of the structure has afire resistance rating of at least one hour. 2. The weatherproof enclosure is constructed of noncombustible materials and It has been demonstrated that a fire within the enclosure will not Ignite combustible materials outside the enclosure. Annex A -- Explanatory Material A4.1 A (2) Means of demonstrating compliance are by means of full scale fire test or by calculation procedures. Because of the limited spaces that are frequently available for Installation, it has become apparent that exception (2) would be beneficial for many residential and commercial Installations. With that in mind, the manufacturer contracted with an independent testing laboratory to run full scale fire tests to assure that the enclosure will not ignite combustible materials outside the enclosure. NOTE: Southwest Research Institute testing approves 18 in (457 mm) Installation minimum from structure (•'=5=F1-o�:', C). Southwest Research institute is a nationally recognized third party testing and listing agency. The Qrlterla was to determine the worst Case fire scenario within the generator and to determine the Ign)tability, of items outside the engine enclosure at various distances. The enclosure is constructed of non-combustible materials, and the results and conclusions from the independent testing lab indicated that any fire within the 12 I Installation Guidelines For 60 HzAlr-Cooled Generators 1 r Site Selection and Preparation generator enclosure would not pose any Ignition risk to nearby combustibles or structures, with or without fire service personnel response. Wnn�..� — s:» ft-1 wtaxes � i i g0 aiAR �` +NOSE 4 in CHAR � NOTE 8 0 CHAR NOSE 8 0 CHAR "-�.....a ®--�" W M 7 00 CHAR. Figure 2-2. Southwest Research Institute Marlsirrg Based on this testing and the requirements of NFPA 37, Sec 4.1.4, the guidelines for Installation of the generators listed above are changed to 18 in (457 mm) from the back side of the generator to a stationary wall or building (C). For adequate maintenance and eir`Iow clearance, the area above the generator should be at least 5 ft (1.52 m) with a minimum of 3 ft (0.91 m) at the front and ends of the enclosure. This includes trees, shrubs, and bushes. Vegetation not in compliance with these clearance parameters could obstruct air now. in addition, exhaust fumes from the generator could inhibit plant growth. See jT.- :"s �'4 and the installation drawing within the owner's manual for details. Automatic start-up. Disconnect utility power and render unit Inoperable before working on unit. Failure to do so will result In death or serious lnjury. (000191) Site Preparation ° Locate the mounting area as close as possible to the transfer switch and fuel supply. o Leave adequate room arourid the area for service access (check local code), and place high enough to keep rising water from reaching the generator. ° Choose an open space that will provide adequate and unobstructed airflow. Place the unit so air vents won't become clogged with leaves, grass, snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, ventilation fans, or other air Intakes (see ° Select the type of base, such as —but not limited to --compacted soil, gravel, or concrete, as desired or as required by local laws or codes. Verify your local requirements before selecting. Material Sufficient for Level Installation Prepare a rectangular area approximately 5 in (127 mm) deep (A) and approximately 6 In (152 mm) longer and wider (B) than the footprint of the generator. Verify that the surface where the generator will be mounted is compacted, leveled, and will not erode over time. A concrete pad can be poured if desired or required. gay ^-w1,y-at,un, mountng engines produce Figure 3►3 Compacted Sol1 or travel pad carbon monoxide, a c000rless, odorless, avoided, Will result in deatohnor serrious to u NOTE: If a concrete pad Is required, follow ail applicable (000103) federal, state, or local codes. OTL: If the generator is not set to OFF, It can crank and ;art as soon as the battery cables are connected. If the !Pity power supply Is not turned off, sparking can occur the battery posts and cause an explosion. .+rn�1G111 i= rut ov nz mr-umiea (jenerators- 93