HomeMy WebLinkAboutPRODUCT APPROVAL FIXED WINDOWS6/13/2018 BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge rProduct Approval USER: Public User , Florida )Building Code Online f lit, Stets & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search SCANNED Y Product ARoroval Menu > Product or ARplication Search > 6polication List > Application Detail ] a Ip.lj%nl 0 C �pnt , FL # FL13010-R6 l5 i4U1�pV 4Jltl VI�1V Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived 0 �%!j� G�2 %O Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 �0ontp (352) 368-6922 Ext 245 kpine@cws.cc G'�?j�, E Authorized Signature Kevin Pine kpine@cws.cc Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Quality Assurance Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications, Inc. Validated By Steven M. Urich, PE Oe Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-05 2005 AAMA/WDMA/CSA 101/I.S.2/A440-08 2008 a ASTM E1886-05 2005 ASTM E1996-05 2005 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By _app_dtl.aspx?param=wGEVXQwtDgvQEb8FEH60Vrs5wFsWUkbaazonS2SDienp6kee9uGfEA%3d%3d 1/3 6/13/2018 i i Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida 13uilding Code Online Method 1 Option A 05/30/2018 05/31/2018 06/10/2018 FL # Model, Number or Name Description 13010.1 PW-8150 PVC Fixed Window PW-8150 PVC Fig/Fin Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010 R6 C CAC CAR 138-1357.pf Approved for use outside HVHZ: Yes FL13010 R6 C CAC CAR 138-1362.pdf Impact Resistant: Yes FL13010 R6 C CAC CAR 138-562.pdf Design Pressure: N/A Quality Assurance Contract Expiration Date Other: PW-8150, 36" x 72" and 72" x 76" see installation 09/14/2019 detail for DPs. Large Missile Impact. In HVHZ may only be used Installation Instructions up to 30ft above grade. Glass complies to ASTM E1300-04. FL13010 R6 II CWS-433D.W Verified By: Lucas A. Turner 58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalRep2rt433 -j& Created by Independent Third Party: Yes 13010.2 PW-8150 PVC Fixed Window PW-8150 PVC Fig/Fin Fixed Window, Continuous Head & Sill. Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010 R6 C CAC CAR 138-261e2.pd Approved for use outside HVHZ: Yes FL13010 R6 C CAC CAR 138-705aZ= Impact Resistant: Yes FL13010 R6 C CAC CAR 138-706e2.pdf Design Pressure: +67.5/-67.5 Quality Assurance Contract Expiration Date Other: Large Missile, Dp = +/- 67.5 psf, Max. size 74 1/8" x 08/12/2019 72". Outer lite must be safety glass above 30 ft. in HVHZ. Installation Instructions Glass complies to ASTM E1300-04. FL13010 R6 II CWS-510C.pd Verified By: Lucas A. Turner 58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalRep2rt5 QC.pdf Created by Independent Third Party: Yes 13010.3 PW-8300 PVC Fixed Window PW-8300 PVC Fig/Fin Fixed Window, 120" x 48" Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010 R6 C CAC CAR 138-258e2.pdf Approved for use outside HVHZ: Yes FL13010 R6 C CAC CAR 138-481e2.pdf Impact Resistant: Yes FL13010 R6 C CAC CAR 138-482e2.pdf Design Pressure: +70/-70 Quality Assurance Contract Expiration Date Other: PW-8300, 120" x 48", DP = +/- 70 psf. Large Missile 04/09/2019 Impact. Glass complies to ASTM E1300-04. Installation Instructions FL13010 R6 II CWS-373C.pdf Verified By: Lucas A. Turner, P.E. FL PE #58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalReport373C.pdf Created by Independent Third Party: Yes 13010.4 PW-8300 PVC Fixed Window PW-8300 PVC Fig/Fin Fixed Window, 120" x 48" Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010 R6 C CAC CAR 138-1093.pdf Approved for use outside HVHZ: Yes FL13010 R6 C CAC CAR 138-1320 e2.pd Impact Resistant: Yes FL13010 R6 C CAC CAR 138-250.W Design Pressure: +70/-70 FL13010 R6 C CAC CAR 138-274e2.W Other: PW-8300, 120" x 48", DP = +/- 70 psf. Large Missile FL13010 R6 C CAC CAR 138-457.= Impact. Glass complies to ASTM E1300-04. FL13010 R6 C CAC CAR 138-465.pdf FL13010 R6 C CAC CAR 138-534.pjff FL13010 R6 C CAC CAR 138-730e2.pdf FL13010 R6 C CAC CAR 138-739e2.W Quality Assurance Contract Expiration Date 03/16/2020 Installation Instructions FL13010 R6 II CWS-159E.pdf Verified By: Lucas A. Turner, P.E. FL PE #58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalReport159E.pd Created by Independent Third Party: Yes liding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvQEbBFEH6OVrs5wFsWUkbaazonS2SDienp6kee9uGfEA%3d%3d 2/3 6/13/2018 Florida Building Code Online Back Next Contact Us :: 2601 Blair Stone -Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Cony fight 2007-2013 State of Florida.:: Privacy Statement :: Accessibi fty Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 0 11-M-AJ ® ECMrk Cr.',edit U d :Safe _app_dtl.aspx?param=wGEVXQwtDgvQEb8FEH60Vrs5wFsWUkbaazonS2SDienp6kee9uGfEA%3d%3d 3/3 � - `1239 Jabara Ave. URNER North PortFL 34288 ENGINEERING & Ph. 941-3 80-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 159E September 7, 2017 Product Description: Series 8300 PVC Fixed Window, Large Missile Impact, 48" x 72" unit size DP55 or 72" x 76" unit size DP67.5 (DP65 outside HVHZ) Manufacturer: Custom Window Systems, Inc. 1900 SW 44 h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6`h Edition (2017) Florida Building Code including the HVHZ. The product testing. standards performed are outlined below. Technical Documentation: 1) This "report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-159E, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3954-01 and 4A, and NCTL-210-3955-01 and 4A, from National Certified Testing Laboratories, Orlando, FL, with Testing Performed: AAMA/WDMA/CSA 101/I.S.2/A440-08, ASTM El886-05, ASTM E1996-05/09 and TAS 201, 202, 203 1994 (TAS reports 3954-1A and 39554A signed and sealed by Gerard J. Ferrara, P.E.) 4) Supplemental Calculations to support CWS-159E, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-159E. Limitations of Use: This product: • May be used in O configuration in sizes up to 48" x 72" unit size at design pressures of +/-55 psf, or in sizes up to 72" x 76" unit size at design pressures of +/-67.5 psf in HVHZ or +/-65 psf outside the HVHZ, with max. glass daylight sizes as shown in CWS-159E • Is large missile impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires outer lite in I.G. to be safety glass when used in HVHZ above 30 ft of grade • Requires glazing as shown in CWS-159E, with Kuraray (Dupont) SentryGlas Interlayer per Miami -Dade NOA 14-0916.11 t in DP65 or 67.5 units or Kuraray (Dupont )PVB Interlayer per Miami -Dade NOA 16-11-17.02t in DP55 units • Requires Quanex (Milffon) white rigid PVC framing per Miami -Dade NOA 17-0206.1 Ot t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 6'" Ed. (2017) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. *IUR�E►�P �,�iji �*.....,, �ti4�Q �. "i3O E N Lucas Turner No 58201 2017-09-16 �` * 9/07/2017 07:24+20:00 ;. STATE OF ;' Lucas A. Turner, P.E. '�,�0,4, s FL PE #58201 PICTURE WINDOW - LARGE MISSILE IMPACT 49 1/4' MAX. OVERALL FLANGE WIDTH 48" MAX UNIT WIDTH 45 1/8' GLASS DLO A —� 731/4' I MAX. OVERALL FLANGE B I O IT 69 1/8- y GLASS DLO I . I I A A. TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS .......I ARCHITECTURAL SHAPES...................2 GLAZING DETAILS.................................3 SECTION VIEWS....................................4 EXTRUSIONS & B.O.M...........................5 ANCHOR SCHEDULE & NOTES ......... 6-7 INSTALLATION DETAILS.......................8 GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED um�m" TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRINCANE ZONE (HVHZ) 1900 SW 44TH AVE. 1900 SA.4THFLORIDA E. AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS OCAWWW DEFINED IN ASTM E 1996 PER THE FBC. CF34474 2. GLAZING OPTIONS: (SEE SHEET 3) 8300 PVC 3. CONFIGURATIONS: "O'. ARCHITECTURAL SHAPES INCLUDE, BUT ARE PICTURE WINDOW NOT LIMITED TO, THOSE SHOWN ON SHEET 2. IMPACT 4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/O9. -� z -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER H o w p to O O INFILTRATION TEST PRESSURE AND GLASS TABLES z w -i ❑ a k w z ASTM E-1300-04e01/09. w LL z o z w m ?� r_ 5. ANCHORAGE: THE 331/3% STRESS INCREASE HAS NOT BEEN USED z z x 2 ¢ lxw p 0 IN THE DESIGN OF THIS PRODUCT. SEE SHEET 8 FOR ANCHOR O O I- O U Q = I- ix U y z n F w D. DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD 3 z — V- O ANCHOR CALCULATIONS. Z V vi Z� I--LL�OOI'-z 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT � 0 Fw- F- F Z — REQUIRED. FQ W w 'n j ?f 0 C6 21�U)0wcow 7. ALL FRAMES ARE FULLY WELDED. a Z.= nw. o �O co � j 8. SERIES / MODEL DESIGNATION PW-8300. 0 m w P 0 ax�> � w uj � w 9. THE DESIGNATION XAND O STAND FOR THE FOLLOWING: �i�uup 0 = FIXED SASH. 1 SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR :,CAP`:SFT(.,pti�% LOCATION. : J�' m, s sr�n' t�nL LucasTurner 2017-09-22 11:45-04:00 LOCATION MAX. UNIT SIZE I DESIGN PRESSURE. RATING IMPACT RATING ANY 48" X 72" +/- 55 PSF LARGE MISSILE IMPACT NON-HVHZ, + - 72" x 76' HVHZ +/- 67.5 PSF 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. - NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: GENERAL NOTES AND ELEVATIONS AWN BY: DATE: ADE 05/05/07 VG #: REV.: CWS-159 E ALE: SHEET FULL CIRCLE • 112 CIRCLE I' 1/4 CIRCLE FULL ELLIPSE ("OVAL") OCTAGON TRIANGLE TOMBSTONE TRAPEZOID NOTES: 1. SEE SHEETS 6 & 7 FOR DETAILED ANCHOR INSTALLATION REQUIREMENTS. 2. THRU FRAME - MASONRY, WOOD OR METAL OPENING. THRU FIN - WOOD OPENING. 3.OVERALL SIZE MUST NOT EXCEED THE MAX. WIDTH AND HEIGHT OF RECTANGULAR WINDOWS ON SHEET 1. 4. ANCHOR SPACING FOR ARCHITECTUAL FLANGE AND FIN WINDOWS MUST FOLLOW THE LAYOUTS SHOWN ON SHEETS 6 & 7, WITH ANCHOR SPACING MEASURED ALONG THE LENGTH OF THE PRODUCT. Dubm' WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.CC 8300 PVC PICTURE WINDOW IMPACT a ? ¢z� z woo awI-0w w zOz O:--t o :74w>O=m LL z Z=N<Xwoo U U—0za-Pena.. yZ Z OC)Vw—=)O— 4 -?LLMOOOU- > ¢3Ow—x0_ z W Oaxwowmw 2 ?0a o-1mF a.o w�� w=ww a! x a a it wa z� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: RCHITECTURAL SHAPES LAWN BY: DATE: ADE 05/05/07 VG p: REV.: CWS-159 E ALE: SHEET 1" OVERALL 3/16' ANNEALED or TEMPERED ' 1/2' AIRSPACE 5/16" LAMINATED- 1/8' ANNEALED .090 DUPONT PVB INTERLAYER 1/8' ANNEALED ' DURASEAL IG SPACER IG SPACER PURFECT GLAZE "H" 6 SIKAFLEX 552 QUANEX DURASEAL IG SPACER 10 1/2' GLASS BITE 10 •17 7 �J� � GLASS TYPE A SETTING BLOCKS PER FBC 2411.3.3.1 1" OVERALL 3/16" HEAT STRENGTH or TEMPERED 3/8" AIRSPACE 7/16" LAMI GLASS 3116" HEAT STRENGTH .090 SENTRY GLASS IONOPLAST INTERLAYER 3/16" HEAT STRENGTH PURFECT GLAZE "H" SIKAFLEX 552 J 1/2" GLASS BITE GLASS TYPE B C GLASS MAXSIZE TYPE W x H DP +/-55 A 48 X 72 DP +/-67.5 B 72 X 76 goffig WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc 8300 PVC PICTURE WINDOW IMPACT z ¢z3 z WJ❑ -w W zOz D'=zI_' 0 Z Z2mQffWOOO U 0coOVaHv7a CO Z p l --no— �30FFF0— z it 1~11 000�(�l75WfOW rnWa O -jaOI- O W~� w=mvi a F a O3a ,� %%sU ,% � Pp1DREW -j: No 58201 t T y9at STATE OF 1411u? ' 4 O R 10 P'j\a��� �4 iS�ONA z� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 MEET DESCRIPTION: GLAZING DETAILS )RAWN BY: DATE: ADE 05/05/07 )WG#: REV.: CWS-159 E 'GALE: SHEET i 5n m n O z m D D Dr m m -�z m m m z u �V Ct u m m 9 O z Z m m 0 G�i m D f m m � f155ing1/ & 'c k ����,,' PROPRIETARY AND CONFIDENTIAL ••• � 0-8 I °i v m j 1 N W nco r- THE INFORMATION CONTAINED IN 'Sc' C p� cc O Z a z D jv v. O m 1a �1D#C Co. i m �O y 2 9'� THIS DRAWING IS THE SOLE N �O: i o 0. �{ = z• o o• o PROPERTY OF CUSTOM WINDOW N 1 ` 7� * m,A: o" a D: m z; rt5 a SYSTEMS, INC. ANY 1 'r W �� O V m O_ D y r o f 0— y > m o m 4 m Z r D No 1 o O o y' REPRODUCTION IN PART OR AS A v %my�,Y m �'=y WHOLE WITHOUTTHE WRITTEN (7 k+ m �^ y m m y cn a m' '�,�G'�••.• PERMISSION OF CUSTOM WINDOW Z a m '�.,'E.........j�i� SYSTEMS, INC p -mj o .�" IS PROHIBITED. QC ai C PARTS LIST ITEM PART # DESCRIPTION VENDOR MATERIAL 1 H-6006B FRAME, PW, MAIN, HEAD MIKRON PVC 2 H-6006B FRAME, PW, MAIN, SILL MIKRON PVC 3 H-6006B FRAME, PW, MAIN, L. JAMB MIKRON PVC 4 H-6006B FRAME, PW, MAIN, R. JAMB MIKRON PVC 5 H-6006A FRAME, PW, MAIN, FIN MIKRON PVC 6 P-3113 SCREW SUPPORT FOR PVC TEAM PLASTIC RUBBER 7 P-3352 SET. BLK., 85 DUR., 1/8" x 5/8" x 2" LG. FRANK LOWE RUBBER 8 PURFECT GLAZE "H", SIKAFLEX 552 HENKEL / SIKA SILICONE 9 P-3752 CAP PLUG, 1/2" HOLE M&M SILICONE S-6064 GLZ. BE., FXD. (1" O.A. I.G.) MIKRON PVC GLASS SEE SHEET 3 3 1/8° Li 21/18° PVC FRAME FLANGE - H-6006B 114" 1/16° 7/8' 10 PVC GLAZEBEAD - S-6064 2 PVC FRAME FIN - H-6006A 1� 3" SCREW SUPPORT - P-3113 2AME CORNER CONSTRUCTION�//77((��v9�j///�J) WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.Cc CORNER WELD (ALL SIDES) 8300 PVC SCALE 1:8 PICTURE WINDOW IMPACT a i 3 <z3 QWoaZwzw w 3'aO z Z'2<0Y.80 (0.1 U��VaFWa Z Q D Z Z j U w } «0W-20_ W 0"�eOW(AW to CL 0 � =~a Wow"' a I- D. 46 No 58201 :?1: �90� STATE OF 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: EXTRUSIONS & B.O.M. AWNBY: DATE: ADE 05/05/07 VG #: REV.: CWS-159 E ALE: SHEET 14' MAX. 6' MAX 6' MAX i 1, M (1 ANCHOR LAYOUT - (FLANGE) DP +/- 55 PSF 4" MAX. i TE2 4' MAX 8' MAXI (TYP. INSTALLATION ANCHOR (TYP.) 0 ANCHOR LAYOUT - (FIN) OP +/- 55 PSF cmg®m WINDOW SYSTEMS E 2 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8300 PVC PICTURE WINDOW INSTALLATION IMPACT ANCHOR (TYP.) NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. ANCHOR SPACING APPLIES TO ALL SHAPES (SEE SHEET 2) ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2. iS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE 'RUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 8. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 8. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 8. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: Q Z 3: az0 i--OWO Qz WOW z WJO o <III CO OE:m U U~Oa=F--x Z�OZZF�CD Q O Z O O Z O W O }� �owr�0Z z w LL Mw(Dw zoww 0-1m1-- w =~K W w m M X AV-11 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 iEET DESCRIPTION: ANCHOR SCHEDULE & NOTES iAWNBY: DATE: ADE 05/05/07 NG #: REV.: CWS-159 E 6' MAX. 6' MAX. 7 5/8" MAXI (TYP. 4' MAX. 2 4' MAX. INSTALLATION ANCHOR (TYP.) ANCHOR LAYOUT - (FIN) DP +/- 65 PSF a0ga m WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWw.CWS.Cc 8300 PVC PICTURE WINDOW IMPACT Q Z QZD I- OWE W o ' Z WJ❑ W Z_OZ mr-zF Q Z z=m<XWOO U U~FVa2F mF-Z ranD- Q OZOOZO 0 1--Iim00LLZ w Q30WF,F0— 2N ~ W LLc11W�0-1 z— a o W�0 a.xX NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. ANCHOR SPACING APPLIES TO ALL SHAPES (SEE SHEET 2) ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2. ' LS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16' IS PRESENT. LOAD BEARING SHIMS SHALL BE ,'RUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 8. 9/22/2017 LUCAS A. TURNER, P.E. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST FL l #BARA BE PROTECTED TO PREVENT REACTION. 1239 JA A AVE.A 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT, FL 34288 PH. 941-380-1574 SPECIFIED IN TABLE 1, SHEET 8. SHEET DESCRIPTION: 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. ANCHOR SCHEDULE 8 INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL. DRAWN BY: DATE: ADE 05/05/07 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG u: REV,: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLEI, SHEET 8. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-159 E 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AARAA 90IVPIN wiKinnWF\ FMA/AAMA gnnim ANf7F WINIV1W6t1 FMANVTIMA 9E,OfRf]X WINnnw.g1 FMA/AAMAtwnMA 300fFXTFRIOR TInORSI _ _ — SCALE: -,3n SHEET _-..�-..—.._ SUBSTRATE BY OTHERS--,, SEE TABLE 1 PERIMETER SEALANT BYINSTALLER INSIDE AND OUT SEALANT BEHIND FLANGE BY INSTALLER INSTALLATION ANCHOR SEE TABLE 1 TYPICAL HEAD ANCHORAGE MIN. EDGE DIST. SEE TABLE 1 MIN. EMBEDMENT SEE TABLE 1 1/4" MAX. SHIM MIN. EMBEDMENT SEE TABLE I SUBSTRATE BY OTHERS 1/4' MAX. SHIM SEE TABjILE 1 MIN. EDGE DIST. SEE TABLE 1 INSTALLATION ANCHOR SEE TABLE 1 PERIMETER SEALANT BY INSTALLER INSIDE AND OUT SEALANT BEHIND Fl ANGE BY INSTALLE B 1 HORIZONTAL SECTION 8 TYPICAL JAMB ANCHORAGE 1/4' MAX. SHIM SEALANT BEHIND FLANGE BY INSTALLER 0 PERIMETER SEALANT MIN. EMBEDMENT BY INSTALLER INSIDE AND OUT SEE TABLE 1 SUBSTRATE BY OTHERSlo SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 SEALANT UNDER SCREW � VERTICAL SECTION . HPan My INSTALLER 8 TYPICAL SILL ANCHORAGE TABLE 1: APPROVED INSTALLATION FASTENERS . LANGE CONCRETE (2.0 KSI MIN.) FLANGE — FLANGE CONCRETE (2.85 KSI MIN.) FLANGE GROUT -FILLED CMU (ASTM C-90) FLANGE 2XMIN. SOUTHERN PINE (G=0.55) FLANGE 12XMIN. SOUTHERN PINE (G=0.55) FLANGE 16 GAUGE (0.060") MIN. STEEL ST (33 KSI YIELD MIN) 11/8' FLANGE 1/8" ALUM.. (6063-T5 MIN.) OR STEEL (33 KSI MIN.) i" ELCO ULTRACON 1" 1" i" ELCO ULTRACON 1-1/4" 2-1/2' i" ITW TAPCON 1-3/8" 7/8" ELCO ULTRACON WOOD SCREW 1-3/8" 7/8" -16 HLTI KW IK-FLEX OR ITW FULL THREAD :S SELF -DRILLING SCREW THRU 0.060" 7/16" GRADE 5 SELF -TAPPING / FULL THREAD LUNG SCREW I THRU 0.125" 7/16' asINDOWggpx.r�m SYSTEMS MIN. EDGE DIST. SEE TABLE 1 SUBSTRATE BY OTHERS SEE TABLE 1 1900 SW 44TH AVE. OCALA, FLORIDA 34474 1/4" MAX. SHIM WWW.CWS.CC O� S ETABLE DMENT 8300 PVC PICTURE WINDOW IMPACT Q Z 3: <Z3: PERIMETER SEALANT z w J o ¢ W O W BYNSTALLER INSIDE AND OUT W 9 LL Z 0 Z Q m�i} O W3: m INSTALLATION ANCHOR Z Z= 2< of W O0 00 SEE TABLE I SEALANT BEHIND 0 00 O F- O Lj Q=I.- w Z— co Z Z I_� cn FIN BY INSTALLER Z 0 0 V 0 0— %� HORIZONTAL SECTION Q X F- — LLM O O LL Z 8 TYPICAL FIN ANCHORAGE HEAD AND SILL SIMILAR FOR FIN INSTALLATION F 2 �.0 � F- F-- Z 0.ui O LJJ O } ui LLc) 0JCnF- a co O WF-LL0,' W=�(ni a F a 0: a. ,`4�tuuur", pr10REW T ,,,. ,��.�` E N sF GPyc��. `.JVP°.:��C : t : No 58201xx �9' STATE OF :�kl�: ��i In •; O R 1 �. G�,�� ociETE_:P- `yy 1 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 >PERIMETER 1239 JABARA AVE. SEALANT--- EALANT BY INSTALLER NORTH PORT, FL 34288 INSIDE AND OUT PH. 941-380-1674 HORIZONTAL SECTION SHEET DESCRIPTION: B BOX FRAME INSTALLATION HEAD AND SILL SIMILAR FOR BOX INSTALLATION INSTALLATION DETAILS FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: ADE 05/05/07 MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED DWG #: REV.: INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. CWS-159 E PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SCALE: SHEET SHOWN FOR FLANGE WINDOWS. — 4 ____�_