Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL SINGLE HUNG WINDOWS 8-23-171/4/2018 Florida Building Code Online I;I BCIS Home Log In User Registration Hot Topics I Submit Surcharge I Stats & Facts Publications FBC Staff I BCIS Site Map I Links Search product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL16177-R2 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email' Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method C Custom Window Systems Inc. 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext245 kpine@cws.cc Kevin Pine kpine@cws.cc ]ay Lathrop 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Arturo Monteverde 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext221 amonteverde@cws.cc Windows Single Hung SGANNED By St. ft pe ?0117 `LOc o Scol p , ty Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A. Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich, PE RI Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Standard AAMA/W DMA/CSA/101/I. S.2/A440-08 ASTM E1886-05 ASTM E1996-09 PA TAS 201/202/203 Year 2008 2005 2009 1994 Equivalence of Product Standards Certified By _app_dti.aspx?param=wGEVXQwtDgvyf4ngAXh10y8QtjDbmBlPrafAGHlxlsgtjUObEAbzoQ%3d%3d 1/2 1/4/2018 4 Sections from the Code Florida Building Code Online x [ Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/28/2017 09/29/2017 10/03/2017 12/12/2017 FL # Model, Number or Name Description 16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window. Limits of use Installation Instructions Approved for use in HVHZ: Yes FL16177 R2 II CWS-812C.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: SH-8100 PVC Impact, no sill anchors required. Safety FL16177 R2 AE EvalRenort812C.pdf glazing required on outer lite above 30 ft. in HVHZ. Glass Created by Independent Third Party: Yes complies to ASTM E1300-04. Back Poext Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessi611ity Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® eche'cE •M f CreditCard, i Safe.. oddabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDqvyf4ngAXhl Oy8QtjDbmBiPrafAGHlxlsgtjUObEAbzoQ%3d%3d 2/2 Ff 1239 Jabara Ave. URNER North Port, FL 34288 ENGINEERING & Ph. 941-3 80-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 812C August 29, 2017 Product Description: Series 8100 PVC "Single Hung, Large Missile Impact, 51 7/8" x 61 3/4" unit size, +/-70 PSF, no anchors in sill Manufacturer: Custom Window Systems, Inc. 1900 SW 4,e Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4.). , This product complies with the requirements of the 6`h Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-812C, signed and sealed by Lucas A. Turner, P.E. 3) Test Report NCTL-210-3815-1A, -2, and -2A, by National Certified Testing Laboratories, Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed:' TAS 201/202/203- 94, ASTM E 1886-02/04/05, 1996-02/04/06/09, and AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support CWS-812C, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-812C. Limitations of Use: This product: • May be used in O/X configuration in sizes and with max. glass DLO heights as shown in CWS- 812C • Is impact resistant and does not require the use of shutters, • May be used in the High Velocity Hurricane Zone • Requires 7/8" Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite (Tempered required above 30, ft in HVHZ) — Air — 5116 Laminated (1/8Ann-.090PVB-1/8Ann) inboard lite • Requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-1117.021 • Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.101 t I have evaluated the materials in these NOAs and find that they comply with the requirements of the 6'h Ed. (2017) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. Lucas H1 582Zp Turner' 2017-08-30 ; `+ S1 •• STATfi OF . 4U 16:11 +20:00 '�,�„•�.�.',+ 8/29/2017 '`►10 '.? 1:�•'���� �'rrr�C)NAI-JJ;+��� Lucas A. Turner P.E. FL PE #58201 SINGLE HUNG.- LARGE MISSILE IMPACT 63" MAX. OVERALL FLANGE HEIGHT B 61 314" i 30 3/16" MAX SASH ' HEIGHT - a TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS GLAZING DETAIL.................................2 SECTION VIEWS.................................3 EXTRUSIONS & B.O.M.......................A ANCHOR SCHEDULE & NOTES INSTALLATION DETAILS....................6 1/8' MAX. OVERALL FLANGE WIDTH —51 718" MAX. UNIT WIDTH —4711/16" GLASS DLO A �- C B 1 I I I 28 7/8' X I I GLASS DLO B 6 I C 1 6 A — 451116" GLASS DLO 48 318" MAX. SASH WIDTH GENERAL NOTES: uw90m-C/ 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WINDOW SYSTEMS %j�"7j L`�J TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA, FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2. GLAZING OPTIONS: (SEE SHEET 2) 8100 PVC 3. CONFIGURATIONS: 'CDC. SINGLE HUNG 4. DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER O INFILTRATION TEST PRESSURE AND GLASS TABLES F o w o ASTM E-1300-04e01/09. z w w❑ ¢ Z w BEEN USED w 0 z0z w - - t= Q co ?� } O M � m 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT LL F-w ZF-3:N2 IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR z0 H 0 ¢ 4 IU 0 0 DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD Oz U w z Z CL ANCHOR CALCULATIONS. Z > CO 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. zaaZ ¢ Z LL O z 0 LL O 0 OFF Z z ¢ Fw- 7 SMALL JOINT SEAM SEALANT ATMES AND VENTS FULLY WELDED. 2 ���}Z 0m U) Wco 00 J co H USED FIXED MEETING RAIL AND JAMB. Z a 8. SERIES / MODEL DESIGNATION SH-8100. 0 w wH0 a.2�� x a � w a I- a 9. THE DESIGNATION XAND O STAND FOR THE FOLLOWING: pu sAll"� X = OPERABLE SASH, O = FIXED SASH w�p�y.TG'', 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR ; '� SF '•,'L1:� LOCATION. jG �' No 58201 % 11. EXTERNAL WEEP SLOT =1/4" x 1-1/4" LOCATED 4" FROM BOTH ENDS. DESIGN PRESSURE MAX. UNIT SIZE RATING IMPACT RATING 51-7/8" x 61-3/4" +/- 70 PSF LARGE MISSILE IMPACT LucasTurne r 2017-09-22 13:36-04:00 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS BAT 06/18/12 /G#: REV.: CWS-812 C ALE: SHEET 7/8' OVERALL INSULATED GLASS 1/8' ANNEALED OR TEMPERED 7/16" AIRSPACE 5116" LAMINATED GLASS 1/8' ANNEALED .090' PVB INTERLAYER BY DUPONT 1/8' ANNEALED QUANEXDURASEAL IG SPACER PURFECT GLAZE W OR SIKAFLEX 552 1/2" GLASS BITE FIXED LITE 718' OVERALL INSULATED GLASS 1/8" ANNEALED OR TEMPERED 7/16" AIRSPACE 5/16' LAMINATED GLASS 1/8' ANNEALED .090" PVB INTERLAYER BY DUPONT 118" ANNEALED QUANEX DURASEAL IG SPACER PURFECT GLAZE "H' OR SIKAFLEX 552 1/2" GLASS BITE aoibma- WINDOW SYSTEMS 1900 SW 44TH AVE: OCALA, FLORIDA 34474 W W W.CWS.CC 8100 PVC SINGLE HUNG IMPACT z 3 azo h owo ¢wow w zoz W--L o a�3>oo!�m Ii F-w Zh3:ME z Z=2<wwoo U U~� d a' fA z ��D z p D-K06 7Uw >- ¢§pw2.=OZ W 00 coCaw wul U. fn W Q J (q F- a =~a ul3w� i pSOREW Al 61 No SB201 k. * '*Z 90:.STATE OF ;tu 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ;HEET DESCRFTION: GLAZING DETAILS )RAWN BY: DATE: BAT 06/18/12 )WGM REV.: CWS-812 C 'GALE: SHEET INTERIOR SECTION A -A NOTE: ITEMS NOT SHOWN FOR CLARITY: 20, 25-26, 36-37, 44, 51-52, 55-56, 64, 67-68 INTERIOR SECTION B-B NOTE: LEFT SIDE SHOWS FIXED SECTION VIEW, RIGHT SIDE SHOWS SASH SECTION VIEW. Qm2m 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8100 PVC SINGLE HUNG IMPACT a z � aZ3 WLuod I- ow0 <F2. Z W z0Z 0_f., O Fw�ZO��2 Z Z=m<ww00 0 Ua)�OaHWaa Z O DZZ7VW ZOOZ a F -u- �300u-Z 0HFC0- z w p0ciaujwuj a Asa wow w =~a uj�a0 a ~ ON VIOPJ=-Vv .� � 5 G i No 58201 ' 9 %13 STATE OF .W •F<ORI;QAG���� /ONA� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SHEET DESCRIF TION: SECTION VIEWS )RAWN BY: DATE: BAT 06/18/12 )WG#: REV.: CWS-812 C SCALE: SHEET 2 or x r4 1 v- osw 1ffa x im-, ran mean, ItK 1 rastenal LINE ITEMS NOT USED: 5, 7, 11, 15-17, 21.22, 29, 31, 33-36, 41-43, 46, 49-50, 55, 57-61, 69 p 1/16° 2 3 10 11116"L 4 1 5/8• q 1/16• - o L 1/16° 0 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. PVC FRAME FLANGE-6031 / 9/16° 0 -V3 /16° REINF., IMPACT HOOK -1112 15/16" 0 7/8• L v1s° .PVC SASH STOP -6025 3/4° 3/16° 13 T 1l16° REINF. S.B.R./S.S.R. -1498 PVC SASH BTM. RAIL-6028 13/16----� 1 1 5/a' 1/16" PVC SASH SIDE RAIL - 6004 18 1/16° PVC SCREEN CATCH - 6013 3/4° 3 15/16' L REINF. BTM RAIL-1699 0 3/16" O . 1 5/16° 6 718• 1/16" �5°� IMPACT HOOK S-1577 f—23/16' 8 PVC SASH TOP RAIL-6027 1 1/2° 1 2 1/16° FD(ED RAIL - 1836 9/7IT16� 1 5/16° 041 PVC FD(ED RAIL COVER- 6063 5/8 ,N6• REINF. TOP RAIL-1497 FRAME CORNER CONSTRUCTION CORNER WELD (ALL SIDES) 1:8 37 FD(ED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME 1:8 5/16' is PVC SCREEN SUPPORT - 6014 1/4• r r 7/8' 7 PVC GLAZING BEAD-6064 1/2" 3/1(1 1 3'---1 ro . SCREW SUPPORT-3113 Qg�mw 1900 SW 44TH AVE. OCALA, FLORIDA U474 W W W.CWS.CC 8100 PVC SINGLE HUNG IMPACT Q z- 3 "¢ZO 1- OUIQW-jo ¢Wpm Q ZwZ}00w?:w Q �zz Z Z 2 m 6 K w o p U OF -OF d LL' - - Z 00=--jU— C Zooz F--LLmLQOLLZ mg z W 0 0 �uu))0 wvQ)w LL u)W QJu)I- a O wF0 (L (L (L X3:w ,�y��uur.ryrr 0%PNOREIV G�CENS No 58201 -°• %'A STATE OF ° AU z� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 68201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 BOM AND EXTRUSIONS BAT 06/18/12 VG #: REV.: CWS-812 C 'ALE:SHEET 6' MAX (TYP.) 6' MAX (TYP.) 10 1/2' MAX O.C. (TlP.) L. 1 4' (TYP.)_I� MAX O.C. (TYP.) 101/� 2' x MAX O.C. (TYP.) I I 4- (TYP.) - - - - - - — S 4" (TYP.) NO ANCHORS REQUIRED IN SILL A ANCHOR LAYOUT - (FLANGE) NOTE 2 INSTALLATION ANCHOR (TYP.) EMTG RAL NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. NO ANCHORS REQUIRED IN SILL. 2 QW14 AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE TRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3.., ;.OR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3' FOR MASONRY, 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMANUDMA 300(EXTERIOR DOORS) ummo 1900 SW 44TH AVE. OCALA, FLORIDA U474 WWW.CWS.Cc 8100 PVC SINGLE HUNG IMPACT Q Z ?: aZ0 awo QIW-o u. �w�zl-3:2x Z Z2�QwwQQ U OFO a¢ w Z �u~ia. w Z Oam-Dw FZCOO a30wI- FQ- W 0`-��O.W fAW fn W Q J fn F p wH� aa=} co a w�W a a 0 ( NDREW r,F4' : No 59201 :11 -*• * :ire 513't •STATE OF :'01� �0Ri0P' N\ 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SCHEDULE AND NOTES BAT 1 06/18/12 CWS-812 C 'ALE: SHEET SUBSTRATE BY OTHERS SEE TABLE 1 PERIMETER SEALANT— BYINSTALLER INSIDE AND OUT SEALANT BEHIND - FLANGE BY INSTALLER INSTALLATION ANCHOR SEE TABLE 1 SEALANT BEHIND FLANGE BY INSTALLER PERIMETER SEALANT- 6M.INSTALLER 6MIDE AND OUT 3 SUBSTRATE BY OTHERS SEE TABLE 1 TYPICAL HEAD ANCHORAGE MIN. EDGE DIST. SEE TABLE I ___ MIN. EMBEDME SEE TABLE 1 1/4" MAX SHIM CONTINUOUS DOUBLE 3/16" BEADS OF TREMGLAZE U1600 SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND BUCK BY INSTALLER. 114" MAX SHIM MIN. EMBEDMENT SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 SECTION TABLE 1: APPROVED LATION FASTENERS ANCHOR TYPE MIN. EMBEDM CONCRETE (2.0 KSI M_ IN.) 3/16" ITW TAPCON 1-1/2" 1-1/8" HOLLO CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON 1" 1" _ GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-1/4" 2-1/2" 2XMIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON OR ELCO ULTRACON 1-3/8" 7/8" 2X.MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/9" 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KW IK-FLEX OR ITW TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.060" 7/16" 1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.) #10 GRADE 5 SELF -TAPPING / DRILLING SCREW FULL THREAD THRU 0.125" 7/16" 9 MIN. EMBEDMENT SEE TABLE 1 SUBSTRATE BY OTHERS uvmm 1900 SW 44TH AVE. 1/4" MAX. SHIM SEE TABLE 1 OCALA, FLORIDA 34474 —1' WWW.CWS.CC MIN. EDGE DIST. SEE TABLE 1 $.� 00 PVC iNSTALLATIONANCFioR SEE TABLE 1 SINGLE HUNG IMPACT �� PERIMETER SEALANT BY INSTALLER INSIDE AND OUT SEALANT BEHIND - FLANGE BY INSTALLER %B HORIZONTAL SECTION 6 TYPICAL JAMB ANCHORAGE PERIMETER SEALANT BYINSTALLER INSIDE AND OUT C HORIZONTAL SECTION 6 BOX FRAME INSTALLATION HEAD AND SILL SIMILAR FOR BOX INSTALLATION FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: - MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. - PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS. Q Z �: ¢ZO I- ❑WO QIW-aO w ZOZ W--t a _ QO>-0w3:m LL I-W�ZI-3: �2 Z Z=2<wwoO UU~�d a uFa O —K{ -D Z �2w FZzOWZ�30F�t-0Z}} 00 =):02— W LLfAW�OJf) 22 z- a O W~a0: w=jai 3: W 9/2212017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 HEET DESCRIPTION: INSTALLATION DETAILS RAWN BY: DATE: BAT 06/18/12 iWG#: REV.: CWS-812 C GALE: SHEET