PRODUCT APPROVAL
FAUG IVED 3 2018 kST. Lucie countvv PQ fylK"129 True Power'"" Electrical Technology Two Line LCD Multilingual Digital Evolution'm Controller (English/Spanish/ French/Portuguese) Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. Electronic Governor System Status & Maintenance Interval LED Indicators Sound Attenuated Enclosure Flexible Fuel Line Connector Direct -To -Dirt Composite Mounting Pad Natural Gas or LP Gas Operation 5 Year Limited Warranty Capability to be installed within 18" (457 mm) of a building* TUBES GENERAL' GUARDIAN° SERIES Residential Standby Generators SCANNED Air -Cooled Gas Engine BY - - Standby Power Rating Models 0007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models 0007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. C @LISTED Note: 0UIET FED Note: CUL certification only applies to unbundled units and units packaged with pre -wired switches. Units packaged with the Smart Switch are UL certified in the *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component, TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA M61-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. LLJ GENERAC at�•3s y �b • � * �', Mobile PROMISE®�e �q� Llnk -Built In fna 1AV umn0 dnm-le and faratpn pM. GENERAC* 16/r 0/22 W features and benefits Engi �1 • G nerac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. I' • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • FuI11 pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • L oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • H�I h temperature shutdown Prevents damage due to overheating. Gene Bator • R Zving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • S hewed stator Produces a smooth output waveform for compatibility with electronic equipment. • D III placed phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • LI 2200 listed For your safety. Tranfer Switch (if applicable) • Ftilly automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • R�imote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolu�t�ion'°' Controls • Alto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • S laled, raised buttons Smooth, weather -resistant user interface for programming and operations. • LA Ility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80°% pick-up, of standard voltage. • G aInerator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • U ility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • E gine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • EIIgine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • P, ogrammable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • S art battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Fain line circuit breaker Protects generator from overload. • E ectronic governor �I Maintains constant 60 Hz frequency. Unit • S E weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • E closed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Instalillation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • D�sect-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 IMpgral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 6/20/22 kW Continuous Power Capacity (NG) Continuous Load Current— 240 Volts Line Circui ier of Rotor generator operating at normal load" of Engine GENERAL specifications 0007035-0,G007035.0, G007038-0,G907039.0 G007042-0,G007043-0 G007037-0 (16 kW) (20 kW) (22 kW) 16,000 Wafts' 18,000 Watts' 19,500 _ 66.6/66.6 83.3/75 91.6/81.3 AR —RI) esx,,th8n >w t ss` harr i9b . 70 Amp 100 Amp 100 Amp 2 1.0 1.0 1.0 `°"�°"�_��7"�is Group>2 R�4D G6A-Minimum rb r�i'oup 357�GM $b0 CGA t�immum �' 406/186 448/203 466/211 66 _ 66 67 cY ^ ---^ 5 min 5 min 5 min GENERAC G-Force 1000 Series GENERAC G-Force 1000 Series GENERAC G-Force 1000 Series 999 cc 999 cc 999 cc ,mil Gast r[ alb S 77- Overhead Valve Overhead Valve Overhead Valve 3,600 c We: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercury) for natural gas,10-12" water column (19-22 mm mercury) foi LP gas. For Btu content, multiply 0/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Controls 2 Se Plain Text Multilingual LCD Display Simple user interface for ease of operation. IN gftl TWA.. ,.,Atikdrt Staff "ontiliur7day9Xet(set.z° . Manual Start with starter control unit stays on If utility fails, transfer to load takes place i .Eg ,9 t., ,h s t St€ rs uni Power is (emoyed C of.an cWryet soli operate to Run/Mamtenance Messages Standard p�RR'R(e�lna (dy L.�"�;.�. Pr grammable start delay between 2-1500 seconds Standard (programmable by dealer only) I�(t !i : tam Loss/Re(ixEktaUttU+Adprs[abla:(giownout Seffn4j . Y z K " Frrxr t4� 17.1;V11 216�- �V " Future Set Capable Exerciser/Exercise Set Error Warning Standard Iart�iMatrdorrance s ��,�<,� ,�:�...�•� E dine Start Sequence Cyclic cranking: i6 sec on, 7 rest (90 sec maximum duration). equency/Overload/Stepper Overcurrent Protection c Low Oil Pressure/High Oil Temperature Shutdov Standard id levels are taken from the frontof the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Rating definitions -Standby. Applicable for supplying emergency power forthe duration utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). • Maximum kilovolt amps and currenlare sublectto and limited by such factors as fuel Btu/megaloule , ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percentfor each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 T) above 16 °C (60 °F). 16/20/22 kW • i Circuits Switch Features Circuits. cally operated, mechanically -held contacts for fast, positive ctions for all classes of load,100% equipment rated, both inductive and pole, 250 VAC contactors. ) millisecond transfer time. tat coil design. ited for both copper and aluminum conductors. ' ain contacts are silver plated or silver alloy to resist welding and sticking. =MA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor ounting flexibility. ulti listed for use with 1" standard, tandem, GFCI and AFCI breakers from emens, Murray, Eaton and Square D for the most flexible and cost effec- re install. tensions 200 Amps 120/240,1e Open Transition Service Rated Height Width H1 H2 W1 W2 Depth I,in 27.24 30.0 11.4 13.5 7.09 gn 692.0 762.4 289. 3343.0 180.0 Note I'iThe 50 amp switcn is flush mountable. H1 and W1 refer to mounting hole spacing. H2 and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover Wirp Ranges I'I Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 210-#14 Ser"'rice Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional • IUp to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • ,hated for all classes of load,100°% equipment rated, both inductive and resis- tive. • Up to four more large (120/240 VAC) loads can be managed when used in con- ijunction with 50 amp Power Management Modules (PMM**). • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • 'Main contacts are silver plated or silver alloy to resist welding and sticking. • INEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height Width I� HI H2 Wi W2 Depth in i1i 27.24 30.0 11.4 13.5 7.09 mm , 692.0 762.4 289.0 343.0 180.0 GENERACW switch options G007036((-jj0 (16kW) /Model _rt�a. t�cs'nf°t�viBs : ,) l 6,2! 9i:' K[ i Current Rating (Amps) 100 Vullagd,;attng(4!k0) Utility Voltage Monitor (Fixed)` -Pick-up 80% -Dropout 65% Ret�to lfrh' �� �� � �.., .;a., ..,, , _. � �"�, . �daP➢ro7c 1 .., F °� ��1 � ..'r� �;, Exerciser bi-weekly for 12 minutes`t Standard Total of Pre -wired Circuits 16 No. 15A120V 5 No. 20 A 120 V 5 No. 20 A 240 V 1 No. 30 A 240 V - No. 40 A 240 V 1 No. 50 A 240 V 1 Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly — DEPTH -I Model G007037-0 (16 kW)/GO07039-0 (20 kW)/ 0007043-0 (22 kW) Current Rating (Amps) 200 Utility Voltage Monitor (Fixed)` -Pick-up -Dropout 80% 65% Exerciser weekly for 12 minutes` Standard Enclosure Type NEMAlUL 3R t ' ;te'akdi; te�c2ed' n22b. Lug Range 250 MCM - #6 *Function of Evolution Controller GENERAC 1 0/22 kW available accessories d�j � ��� '� r' � �s+'�%_' ��"�`W`—�`---�✓'t� �s��' � '"f'`.�„c �. , ��-`"`"".'8 S4 ,,. rasa-_ .�°, Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- 63 4 Mobile Link'" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generators status occurs. Available in the U.S. only. 19-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). 01-0 Battery Pad Warmer The pad warmer rests underthe battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). 02-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0°F. I103 The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers GOOI 0 Breather Warmer only in climates where heavy icing occurs. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G00 621-0 Contact Kit m you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G00 027-0 - Bisque Fascia Base a e Wrap Kit sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting (Standard 22 holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. Z00163.0 Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its Smart Management Module power management capabilities. It provides additional power management f lexibility notfound in any other 1i (50 Amps) power management system. dimensions & PCs Dimensions shown are approbmate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LE17SMVIEW GENERAC® Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 mcwr m Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Pad No.10000000194-C 08/18,,16 HURRICANE CONCRETE PAD FOR GENERAL GENERATORS (GENERAC UNITS) UMITS & REQUIREMENTS OF USE' z 1) THE PAD AND THE SUPPORTED EQUIPMENT MUST BE LOCATED AT GROUND LEVEL. THIS TABLE DOES. NOT APPLY TO ROOFTOP EQUIPMENT, EQUIPMENT LOCATED ON BALCONIES, c c OR ANY OTHER EQUIPMENT TO BE ELEVATED ABOVE GROUND LEVEL $ d 2) THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. MINIMUM SOIL COEFFICIENT OF FRICTION - 0.25 1 3) MAXIMUM DIMENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. PAD WEIGHT TO BE VERIFIED BY OTHERS. 4) ORIGINAL EQUIPMENT MANUFACTURER INSTALLATION INSTRUCTIONS SUPERSEDE HURRICANE PAD INSTALLATION INSTRUCTIONS IF MORE STRINGENT. 31.31n. 5) ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED 31NSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE. ETC.) PAD WOIH SHALL BE AS PER'MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 6) ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, oL a). INDEMNIFIES a SAVES ^��� � HARMLESS THIS ENGINEER FOR ALL COST 8 DAMAGES INCLUDING LEGAL FEES 8 APPELLATE FEES RESULTING FROM MATERIAL FABRICATION. SYSTEM ERECTION, (4 CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL. STATE. 8 FEDERAL CODES 8 FROM DEVIATIONS OF THIS PLAN. 7) THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY. THE ER BE8 9(r>1TOOR ARCHITECTIENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 8) THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. (f! 9) THIS ENGINEER SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS, DIMENSIONS ARE .54.3 6. PhD LCNCIH--.� SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. 10j THIS ENGINEER SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO RE-EVALUATE THIS WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO TYMALAWHORAOe: loT-3I MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. `` {{ {{ / 1W Du -fi1.k 11M.T6 S'W". Eoae 11 ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION. orsTANCE. 1 W EU8M mra CCNMTe (MADE PAN U N TN=HE6a-067ANa MOa 12) EXCEPT ASEXPRESSLY PROMDEDHEREIN. NOADDITIONALCERTIFICATIONSORAFFIRMATIONSAREINTENDED. \�� A`� �, Q� // :•.. SEMMO=KNOT"-eNsg 13) PADS SHALL BE CONSTRUCTED WITH PRECAST CONCRETE, MINIMUM COMPRESSIVE STRENGTH. fc=7.DD0 PSI AT 28 DAYS.C7� / 14) ALL OTHER UNITS NOT SHOWN SHALL BE DESIGNED ON A CASE BY CASE BASIS. iC %Ifs `. 7 15► CONTRACTOR SHALL -PROVIDE SW DIA, (0.675" O.D.) GALV, TUBE ASTM A530 SCH 40 MIN. OR 112' DIA. SOLID COPPER BAR = �4,' � • V F •` ::� � � ''•� SPIKE 4'MIN. EMBED. (SEE MIN. EMBED. AS PER CURRENT ELECTRICAL CODE_ BY OTHERS) INTO GROUND THROUGH CONCRETE PAD FOR SLIDING RESISTANCE PURPOSE.12 DIAMETERS EDGE DISTANCE FROM ANY CONCRETE FACE (NOT SHOWN). No. 80017 16) PADS 1 UNITS INSTALLED DIRECTLY ON ANY COASTLINE REQUIRE A HEAVIER AND LARGER PAD •�- * * ! * �:• TO ACCOUNT FOR EXPOSURE D ; Table 28.3.1. Kr. a 1.03 ENGINEERING DATA: 4 1) Analyses per6th Edition (2017) of8re Florida BuBding Cede -Section 1620 Hlgh Velocity Hurricane Zones. �. STATE OF 2) WIND LOADS B LOAD COMBINATKNIS PER ASCE 7.10 SECTION 2A.1(LOAD COMBINATIONS), SECTION 29.58 O 01 1, - PI : �v� FIGURE 29.5.1 FOR: WIND LOADS ON OTHER STRUCTURES / �. {O \ r 3) RISK CATEGORY = II TABLE 7604.5 - RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES. SECTION 301,16 OF \ 4) THEWINMECHANICAL CODE, WINO ESI Wind TRANCE. AND 55M04OF THE MPH (R RI CATS ORYES WIND STORM LOSS MITIGATION. ���ONAL, ` ���\ \ !, F = gz'G•Cl•A1 (E¢ 29.5.2) c 70.65 -At (ft) 1 qz = 0.00256 • Kz' Kzt' Kd • W2 _ $3.45 PSF � EXP93UM C ; Table 28.3.1 Kx - 0.85 DS�AflF�t3 Figure 2S.8-1 Kzt - 1.00 veruTreeh Corporation Table 26.0.1 Kid= 0.90 6650 $Lwdoaf Parkway #100 Fure29.5.1 o 1.31 lt:)uh[; 1I'11r:=(lemN. 1r�G'nI!nNIr}1 riiN'G i"CfDultdh,3A30097 G. 0.86 800 397-482 L). mig BiNi,: PAGE 1 of 1 UN T I EQUIPMEN FG315440 PAD USED FOR All. 1 180 MPH 0.8(UN T+ PAD) WEIGHT LBS. RESISTING MOMENT FT-LBS DESIGN CHECK. MAXIMUM DIMENSIONS INCHES MINIMUM WEIGHT LBS MODEL NUMBER WEIGHT LBS. PAD WIDTH IN, PAD LENGTH IN. PAD THICK IN, WIND LOAD LBS. 0.6(WIND MOMENT) FT-LBS. WIDTH LENGTH I HEIGHT GENERAC 09 W 25 48 29 340 FG5431-4G 275 31.3 54.3 4 683 632 369.0 481 OK FOR 1 157 1MPH GENERAC 11kW 25 48 29 348 F05431-AG 275 31.3 64.3 4 683 632 373.8 487 OK FOR 1 156 1 M H GENERAC 16kW 25 48 29 406 FG5431-4G 275 31.3 54.3 4 683 632 408.6 533 OK FOR- 166 MPH GENERAL 2DkW 25 48 29 448 FG54314G 275 31.3 64.3 4 883 632 433.8 IS 6 K FOR 1.2 170 MPH GENERA[ 22kW 25 48 29 466 FG5431-4G 275 31.3 54.3 4 683 632 444.E 580 KFOR 171 MPH