HomeMy WebLinkAboutPRODUCT APPROVALGENERAL"
RECEIVED -- ---
Automatic
Trl
,;' Hafer Switches AUG 23 2018 Service and non -Service rated
ST. Lucie County, Permittino tomatic Smart Transfer Switches
100 - 400 Amps, Single Phase
SCANNF-D
BY
She Ud1e, C®t11*,
C&us
LISTED
"CUL only applies to non -service rated switches
*cription
Gen lac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution TM or Nexus"'
Cont'�oller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and
non ervice equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated
equipment configuration.
Standard Features
Serviice rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with
elect",ostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
year of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All
switch, es are covered by a 5 year limited warranty.
* Non -service rated (RXSC) switches are housed in a steel enclosure.
DP Technology
Thro gh the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC
contr 'lled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be
managed as well, providing the most installation efficient power management options available.
ff 4so
GENERAC®
102-400 Amps, Single Phase Automatic Smart Transfer Switches
Fu ctions
All ti ing and sensing functions originate in the generator controller
IlUtility voltage drop-out...................................................................................................................................................................................................................... <65%
imer to generator start . ..........
.......
......
.........................
.......
............
................
............-10 second factory set, adjustable between 2-1500 seconds by a qualified dealer"
Enginewarm up delay.................................................................................................................................................................................................................5 seconds
Standbyvoltage sensor.................................................................................................................................................................................................. 65% for 5 seconds
Utilityvoltage pickup.........................................................................................................................................................................................................................>80%
Re -transfer time delay...............................................................................................................................................................................................................15 seconds
Enginecool -down timer............................................................................................................................................................................................................ 60 seconds
Exerciser..............................................................................................................................................................5 or 12 minutes adjustable weekly/Bi-weekly/Monthly—
The transfer switch can be operated manually without power applied.
When used in conjunction with units utilizing Evolution'" controls —Adjustable via the controller
Mod,l
RXSC100A3
RXSW10OA3
RXSW150A3
RXSC200A3
RXSW200A3
RXSW30OA3
RXSC400A3
RXSW400A3
Amp�
100
100
150
200
200
300
400
400
Volta
° e
120/240, i e
1201240,10
120/240, to
120/240, 1 e
120/240,1 a
120/240, 10
120/240, 1 a
120/240, i e
Load
(Aut
Transition Type
matic)
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Encl
s ,ure Type
NEMA/UL 311
NEMA/UL 311
NEMA/UL 3R
NEMA/UL 311
NEMANL 3R
NEMA/UL 3R
NEMA/UL 311
NEMA/UL 3R
UL Rating
UUCUL
UL
UL
UL/CUL
UL
UL
UUCUL
UL
With
(Am
stand Rating
)
10,000
10,000
22,000
10,000
22,000
22,000
1 22,000
22,000
Lug qange
1/0 - #14
250 MCM - #6
600 MCM
- #4 or 1/0 - 250 MCM
t
I. Model
RXSC10OA3
RXSWIOOA3
RXSW15OA3
RXSC20OA3
RXSW20OA3
RXSW30OA3
RXSC400A3
RXSW40OA3
Ij H1
17.24/437.9
17.24/437.9
26,75/679.4
17.24/437.9
26.75/679.4
42.91/1089.9
31.25/793.8
42.91/1089.9
Heig
I
(inJm
� )
H2
20/508
20/508
30/762
20/508
30/762
48/1219.2
36/914.4
48/1219.2
W1
12.51317.5
12.5/317.5
10.5/266.7
12.5/317.5
10.5/266.7
16.69/423.9
19.18/487.2
16.69/423.9
Widt
(inJm
)
W2
14.6/370.8
14.6/370.8
13.5/342.9
14.6/370.8
13.5/342.9
21.82/554.2
24/609.6
21.82/554.2
Deps
(inJmm)
7.09/180.1
7.09/160.1
6.3/160.1
7.09/180.1
6.3/160.1
10.06/255.5
10.06/255.5
10.06/255.5
Weigli
(lbsJkilos)
20/9.07
22.5/10.21
39/17.69
20/9.07
39/17.69
140/63.5
133/60.33
140/63.5
- DEPTH
C
i
G7 N E RAC' General; Power Systems, Inc. • S45 W29290 HWY.. 59, Waukesha, WI 53189 • generac.com
@2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 10000013459-A 04/24/17