Loading...
HomeMy WebLinkAboutPRODUCT APPROVALI■ Al GENERAC° RECEIVED rotcr° AUG a 3 2a98 PROTECTOR® QS SERIES Brie Standby Generators ST. Lucie County, Permitting Liquid -Cooled Gaseous Engine Two -Line LCD Multilingual Digital Evolution'"" Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position. True Power'" Electrical Technology Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System Smart Battery Charger LIV/Ozone Resistant Hoses ±1 % Voltage Regulation Natural Gas or LP Operation 5 Year Limited Warranty LIL 2200 Listed Capability to be installed within 18" (457) mm of a building* if located away from doors, windows, and fresh air s, and unless otherwise directed by local codes. ATURES Gy INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. Standby Power Rating Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz Model RG032 (Aluminum - Bisque) - 32 kW 60 Hz Model RG038 (Aluminum - Bisque) - 38 kW 60 Hz Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz C E1� QUID tomeflkmYl-bnpW Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant 32 & 38 kW not for sale in CA / MA O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. TEST CRITERIA: O GENERAC TRANSFER SWITCHES. Long life and reliability are d PROTOTYPE TESTED v NEMA M61-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this v SYSTEM TORSIONAL TESTED v MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. TA!W11's 9001: S200H 22 a 27 . 32 . 38 . 48 kW SPECIFICATIONS Type Synchronous Rotlor Insulation Class H (22 & 27 kW) or F (32, 38 & 48 kW) Sta�or Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bongs Sealed Ball Cor piing Flexible Disc Excitation System Direct VOLTAGE REGULATION Typ 'l Electronic Sen ;ing Single Phase Reg lation ± 1°% GOVERNOR SPECIFICATIONS Typcl Electronic Fro' ency Regulation Isochronous Steady State Regulation ± 0.25°% ELECTRICAL SYSTEM Battey Charge Alternator 12 Volt 30 Amp Static!, Battery Charger 2.5 Amp Rec )I )emended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) or Group 24F (48 kW), 525CCA System Voltage 12 Volts GENERATOR FEATURES Rev ;ving field heavy duty generator Dire I connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Cla H insulation is NEMA rated Clas F insulation is NEMA rated All Iodels fully prototyped tested ENCLOSURE FEATURES II Alu 'num weather Ensures protection against mother nature. prot ctive enclosure Electrostaticallyepoxy applied textured P xy Paint for added durability. Encl sed critical grade Quiet, critical grade muffler is mounted inside the unit muff �r to prevent injuries. Sma t, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. (All ra ngs in accordance with BS5514, IS03046, ISO8528, SAE J1349 and DIN6271) GENERAC® application & engineering data ENGINE SPECIFICATIONS: 22, 27, 32 & 38 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3.41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (22 & 27 kW) or Turbocharged/Aftercooled (32 & 38 kW) Lifter Type Hydraulic ENGINE SPECIFICATIONS: 48 kW Make Generac Model V Type Cylinders 8 Displacement (Liters) 5.4 Bore (in/min) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge Crankcase Capacity (qVl) 4/3.8 (22, 27, 32 & 38 kW) or 6/5.7 (48 kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven 1980 - 22 & 27 kW Fan Speed (rpm) 1500 - 32 & 38 kW 1954 - 48 kW 18.1/459.7 (22 & 27 kW) or Fan Diameter (in/mm) 22/558.8 (32, 38 & 48 kW) Pusher (22 & 27 kW) or Fan Mode Puller (32, 38 & 48 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 mm HG LP Fuel Pressure 11 -14" Water Column NG Fuel Pressure 5 -14" Water Column 927*32.38.48kW GENERACO operating data GE I IERATOR OUTPUT VOLTAGEAW - 60 Hz kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both) 120/240 V, 10. 1.0 pf 22 92 22 92 100 R 3022 120/208 V, 30, 0.8 pf 22 76 22 76 80 120/240 V, 30, 0.8 pf 22 66 22 66 80 120/240 V, 10, 1.0 pf 27 113 25 104 125 R 027 120/208 V, 30, 0.8 pf 27 94 25 87 100 120/240 V, 30, 0.8 pf 27 81 25 75 90 120/240 V, 10, 1.0 pf 32 133 32 133 150 120/208 V, 30, 0.8 pf 32 111 32 111 125 R � 032 120/240 V. 30, 0.8 pf 32 96 32 96 100 277/480 V, 30, 0.8 pf 32 48 32 48 60 120/240 V, 10, 1.0 pf 38 158 38 158 175 120/208 V, 30, 0.8 pf 38 132 38 132 150 R 036 120/240 V, 30, 0.8 pf 38 114 38 114 125 277/480 V, 30, 0.8 pf 38 57 38 57 60 120/240 V, 10, 1.0 pf 48 200 48 200 200 120/208 V, 30, 0.8 pf 48 167 48 167 175 R 048 120/240 V, 30, 0.8 pf 48 1 144 1 48 144 1 150 277/480 V, 30, 0.8 pf 48 1 72 1 48 72 1 80 SU 1 GE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @ < .4 pf Natural Gas Propane 15% 30% Wffir) (m,'/hr) (gal/hr) (1/hr) (ft'/hr) 120/240 V, 10 55 135 RG022 120/208 V, 30 40 92 120/240 V, 30 35 80 120/240 V, 10 62 170 R1027 120/208 V, 30 70 120 120/240 V, 30 61 1 103 120/240 V. 10 75 180 120/208 V, 30 87 210 R6032 120/240 V, 30 75 182 277/480 V, 30 36 87 120/240 V, 10 75 180 R 038 120/208 V, 30 87 210 120/240 V, 30 75 182 277/480 V, 30 36 87 120/240 V, 10 85 195 120/208 V, 30 90 218 R 48 120/240 V, 30 78 189 i 277/480 V, 30 36 87 Note: Fuel pipe must be sized for full load. For B u content, multiply ft3/hr x 2520 (LP) or W/hr x 1000 (NG) For a �gajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Refer o "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQ01D permitting purposes. Exercise cycle 42 1.2 0.44 1.7 16 25% of rated load 100 2.8 1.1 4.2 40 RG022 50% of rated load 190 ' 5.4 2.1 7.8 75 75% of rated load 255 7.2 2.8 10.5 101 100% of rated load 316 9 3.4 13 125 Exercise cycle 42 1.2 0.44 1.7 16 RG027 25% of rated load 108 3.1 1.2 4.5 43 50% of rated load 197 5.6 2.1 8.1 78 75% of rated load 287 8.2 3.1 11.8 114 100% of rated load 359 10.2 3.9 14.8 143 Exercise cycle 79 1 2.2 0.8 3.2 30 25% of rated load 144 4.1 1.7 6.3 60 RG032 50°% of rated load 226 6.4 2.7 10.3 97 75°% of rated load 298 6.4 3.7 13.9 132 100% of rated load 375 10.6 4.6 17.5 166 Exercise cycle 83 2.3 0.9 3.2 31 25°% of rated load 162 4.6 1.7 6.6 62 RG038 50% of rated load 255 7.2 2.9 10.8 103 75% of rated load 345 9.8 4 1 15 142 100% of rated load 437 12.4 5.2 19 185 Exercise cycle 95 2.7 1 3.9 38 RG048 25% of rated load 204 5.8 2.16 8.5 82 50°% of rated load 392 11.1 4.14 15.7 151 75% of rated load 547 15.5 5.8 22.8 220 100% of rated load 756 21.5 7.96 31.3 302 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no ipverload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. GENERAC® 22, a 27.32.38.48 kW COOLING operating data 22 kW 27 kW 32 & 38 kW 48 kW Airlflow, (inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 4350/123.2 Sy,�em coolant capacity (gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5 3/11.4 1 e10 rejection to coolant (BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153 186,000/196.2 M#mum operation air temperature on radiator (°C/°F) 60/150 M imum ambient temperature (°C/°F) 50/140 REQUIREMENTS Flo`v at rated power (cfm/cmm) I 68/1.9 I 68/1.9 I 106/3 163/4.6 SOUND EMISSIONS So ' d output in dB(A) at 23 ft (7 m) with generator in exercise mode* 1 61 1 61 1 58 1 63 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 1 70 1 70 1 64 1 68 *S�,AUST lnd levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. EX Exhaust flow at rated output (cfm/cmm) 1 165/4.7 1 180/5.1 1 300/8.5 1 414/11.7 Exhaust temperature at muffler outlet (°CPF) 1 482/900 1 538/1000 1 579/1075 1 552/1025 PARAMETERS Rat ,d Synchronous rpm 1 1800 ADJUSTMENT FOR AMBIENT CONDITIONS lure Deration...........................................................................................................3°% for every 10 °C above 25 °C or 1.65°% for every 10 "F above 77 °F Deration (22, 27 & 48 kW).....................................................................................1 % for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Deration (32 & 38 kW).......................................................................................1 °% for every 100 m above 915 m or 3°% for every 1000 ft above 3000 It FEATURES Two tine Plain Text LCD Display....................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto..............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser Off...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual......................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Proglammable start delay between 10-30 seconds.................................................................................................................................................10 sec standard Engi' a Start Sequence..................................................................................................................... Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration) Engi'e Warm-up.....................................................................................................................................................................................................................5 sec Engia Cool-Down..................................................................................................................................................................................................................1 min r Lock-out................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmaBattery Charger.......................................................................................................................................................................................................Standard Auto atic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................ Standard Autoatic Low Oil Pressure Shutdown............................................................................................................................................................................... Standard Overpeed Shutdown.............................................................................................................................................................................................. Standard, 72 Hz High�femperature Shutdown...............................................................................................................................................................................................Standard Overrank Protection..........................................................................................................................................................................................................Standard SafetpyFused ...................................................................................................................................................................................................................... Standard Failureto Transfer Protection.............................................................................................................................................................................................. Standard LowPattery Protection........................................................................................................................................................................................................ Standard 50 E lent Run Log............................................................................................................................................................................................................... Standard Futua Set Capable Exerciser.............................................................................................................................................................................................. Inco��ect Wiring Protection................................................................................................................................................................................................. Standard Standard InternalFault Protection......................................................................................................................................................:.............................................. Standard CommonExternal Fault Capability......................................................................................................................................................................................Standard Gavenor Failure Protection................................................................................................................................................................................................Standard GENERAC® 927.32.38.48kW available accessories dsi .. _ a d oestr ptio Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with G 06463-4 Mobile Link'"" any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. G006478-0 Harness Adapter Kit The Harness Adapter Kit is required to make liquid -cooled units compatible with Mobile Link'"". G I05630-1 91 - 22, 27, 32 & 38 kW If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit Kit battery G005632-1- 48 kW Cold Weather Kit to maintain optimal battery temperature. consists of warmer with thermostat built into the wrap. G00561 1 6-0 - 22, 27, 32 & 38 kW Extreme Cold Recommended where the temperature regularly falls below 32 OF (0 °C) for G007088-0 - 48 kW Weather Kit extended periods of time. For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged, it is important to G005703-0 - Bisque Paint Kit touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G005656-0 - 22 & 27 kW The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware G005984-0 - 32 & 38 kW Scheduled Maintenance Kit necessary to perform complete maintenance on Generac liquid -cooled G006205-0 - 48 kW generators. G006664-0 Local Wireless Completely wireless and battery powered, Generac's wireless remote monitor Monitor provides you with instant status information without ever leaving the house. G006665-0 Wireless Remote Extension Harness Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater. Smart Management Modules are used in conjunction with the Automatic G0 6873-0 Smart Management Transfer Switch to increase its power management capabilities. It provides Module (50 Amps) additional power management flexibility not found in any other power management system. GO 6510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the I Wi-Fi LP Fuel Level connected LP fuel tank. Monitoring the LP tank's fuel level is an important GO 7005-0 Monitor step in making sure your generator is ready to run during an unexpected i power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. ojra�- 7rot7tor70S Series RADIATOR/EXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES) (BOTH SIDES) BATTERY I2 GRP 26 NEGATIVE GROUND P/N: 077483 V REMOVE COVE FOR ACCESS TC RADIATOR FILL CAP , 427 [16.8] EXHAUST MUFFLER - ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATORIEXHAUST DISCHARGE AIR 141 It- �- 629.9 [24.B] � [5.6] CENTER OF GRAVITY (SEE NOTE 5) TOP VIEW RECOVERY DRIVE BELT EITHER SIDE AN BELT SEE NOTE 11 REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 1040 —� [40.9] 48 48 UEL LINE CONNECTION 3/4" NPT FEMALE COUPLING LEFT SIDE VIEW NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE 1092 (43') WIDE X 1885 (74.2') LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. -REAR ENCLOSURE 980 _ COVER PANEL [38.6] SEE NOTE 4 OVERALL HEIGHT USTOMER ACCESS 48 WL.00ATEDWITHIN SSEMBLY,CONTROL [1.9] ANEL ACCESS, TYP ATTERY CHARGER I SEE NOTE 4 I —776 [30.6]—►I 45 . OVERALL WIDTH [1.8] REARVIEW TYP WEIGHT DATA ENGINEII(W ENCLOSURE WEIGHT GENSET ONLY WEIGHT SHIPPING SKID SHIPPING WEIGHT KVA MATERIAL KG [LBS] KO [LOS] KG [LBS] 2.41- 22KW (60HZ) SINGLE PHASE 17.4KVA(50HZ) AL 410.5[905] 30(66] 440[971] THREE PHASE 22KVA (SOHZ) 24L 27KW (60HZ) SINGLE PHASE 21.6KVA (SOHZ) AL 426 [940] 30 [66] 456 (1DOS] THREE PHASE 27KVA (SOHZ] 631 - 1490 [58.7] TYP - - 1580 [62.2]— OVERALL LENGTH RIGHT SIDE VIEW DIMENSIONS: MM [INCH] VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR CD co m 41 n 2 O N 20 N a' y m z m J� m 0 C 45 [1.8] TOP VIEW LEFT SIDE VIEW IOTE- STUB -UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. RCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING. i STUB -UP COVER 735 [28.9] A116 �AL­l 96 [3.8] 27 [1.0 r= 723 [28.5] TYP TYP MOUNTING SLOT CENTERS 776 [30.6] REAR VIEW DIMENSIONS: MM [INCH] RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) Q 167 [6.6] T 5335 [21.11 z a 2.5" O.D. EXHAUSTn• OUTLET REMOVECOVE FOR ACCESS TO RADIATOR FILL CAP RADIATORfEXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES 768 [30.2] CENTER OF GRf SEE NOTE 5 TOP VIEW `BATTERY 12V, GRP 26 NEGATIVE GROUND PIN: 077483 EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE FUEL LINE CONNECT] 3/4" NPT FEMALE COUPLING LIFTING PROVISIONS (4 PLACES) SEE NOTES 5,7 AND CENTER OF GRAVITY DIMENSIONS REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. 3 NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2255 (88.8'1 LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL CIRCUIT BREAKER INFORMATION: -SEE SPECIFICATION SHEET OR OWNERS MANUAL -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. S. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. VICE ACTION LATCH, ONE PER DOOR, - 759 [29.9] ONE LIFT OFF DOOR TYP DOOR PER SIDE OF GENERATOR • O • ' REAR ENCLOSURE COVER PANEL �r. 1171[46.1]SEE NOTE 4 OVERALLtA rc< HEIGHT USTOMER ACCESS IffASSEMBLY, CONTROLANELACCESSATTERY CHARGEROCATEDWITHINIIIEE 50 [2.0] NOTE 4 i_ 888 [35.0]� 47 1857 [73.1] TYP -158 1000 [39.4]� OVERALL WIDTH 1950 [76.8]� [2.3] LEFT SIDE VIEW Tva] REAR VIEW OVERALLLENGTH TYP ` RIGHT SIDE VIEW WEIGHT DATA ENGINEMW ENCLOSURE WEIGHT GENSET ONLY WEIGHT SHIPPING SKID SHIPPING WEIGHT MATERIAL KG 1LBS1 KG [LBS] KG jLBS] 24L 32KW AL 556112i.5] 441981 1 600[13231 24L3SKW AL 1 5MI12351 1 441981 1 605113331 DIMENSIONS: MM [INCH] W CD cm N � GG W VECTIONS. J OPENING. P ACCESS COVER "H GENERATOR) RING GENERATOR 50 TYP 12.01 Protector® OS Series RADIATOR/EXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES) BATTERY 12 (BOTH SIDES) NEGATIVE GRP 26 GROUND n P/N: 058208 508 [20.0] --►1 240 Ir 19.41 REMOVE COVET FOR ACCESS TO RADIATOR FILL CAP EXHAUST MUFFLE ENCLOSED WITHIN GENERATOR ENCLOSUR 1DIATOR/EXHAUSI DISCHARGE AIR 55 I� 721.4-1.I CENTER OF GRAVITY (SEE NOTE 5) TOP VIEW FUEL LINE CONNECT]ONJLEFT SIDE VIEW 3/4" NPT FEMALE COUPLING RADIATOR"U_CAP ROOFTOP AIR CLEANER ELEMENT EITHER SIDE SPARK PLUGS I EITHER SIDE FAN BELT BATTERY REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 NOTES: 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (477 VIDE X 2256 (88.8' LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: -SEE SPECIFICATION SHEET OR OWNERS MANUAL -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. -LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 518-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 8. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. VICE ACTION LATCH, ONE PER DOOR, TYP-1 ONE LIFT OFF DOOR TYP DOOR PER SIDE OF GENERATOR I 'REAR ENCLOSURE 1170 COVER PANEL [46.1] SEE NOTE 4 OVERALL HEIGHT USTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 1� 868 [ ►1 47 11.8 O 670 —►i OVERALLWIDTH WIDTHIDTH TYp [26.4] REAR VIEW WEIGHT DATA ENCLOSURE WEIGHT WEIGHT SHIPPING WEIGHT ENOINEMW GENSETON- SHIPPINGSKID DIMENSIONS: MM [INCH] MATER W" KG [LBSI KG ILBSI KG ILBS] 5.4L/48KW AL 70S I1555] 44[NJ 75011&931 1857 [73.1] TYP 1950 [76.8] OVERALL LENGTH 58 [2.3] TYP g 1 401, Co o_ N 4g'I M d Z Z .w CO a. ZO OZ WO ZU Z W OZ UZ WO U,U a� . O OU OZ LL P e7 a O U 7 D CO �d 5 IL O r m GENERAC installation layout Drawing #OK9243-B (2 of 2) W W z W U o J Uz CO m NI F D: Z M O U Z �O Z =� O N Z W O 60. N L~ GPNERACA Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 111 @2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin OL0036SBY-J 9/15/17