Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL - METAL ROOFING
F1 nda Building Code Online \ Page 1 of 5 http:/ a+ .,� rw^y 1, d L'. '.3 ��•^3vi.t�..—.:ES ha Y a .,.q �S.4�Hr . y�-... .p�(f♦� .� AR —'-'� BCIS Home ( Log In ; User Registration Hot Topics ? Submit Surcharge ; Stars & Facts Publications ; F8C Staff • BCIS Site Map 1 Links Search i 1`bltda " &+ Product Approval USER: Public User Product AoprovalMenu > Product orpopiication Search > App�ica[ion Lift > Application Detail Q q � j SCAM 11iED FL # FL11651-R3�� BY Application Type RevisionTy �� cle Court Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Gulf Coast Supply & Manufacturing, LLC. 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352)498-0778 info@gulfcoastsupply.com Eng David info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 Info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352) 498-0778 david.eng@gulfcoastsupply.com Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Daniel S. Kuhn the Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications,.Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden P.E. .`+ Validation Checklist - Hardcopy Received Certificate of Independence FL,IM! R3 COI Celt of Indep ur LgDce 2_pdf Referenced Standard and Year (of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580IlC �©�� 2006 .floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwd)gsQFc5K%2frr... 4/16/2018 Building Code Online v Page 2 of 5 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page 'd FL # Model, Number or Name 11651.1 0.032" Aluminum 5V Crimp Method 1 Option D 10/10/2017 10/12/2017 10/17/2017 12/12/2017 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-308.5PSF Other: -108.5 psf @ 12" o.c. Install per manufacturers details. Not for use In HVHZ Zones. 11651.2 10.032" Aluminum Gulf Lok Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. a 4) Page l/2a *b Description Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 1 R3 Metat Roof Panel Q91-21 E signed pgL Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 1_R3 0325vCrimp 15- 32Plvwood Non HVHZ-signed.pdf Created by Independent Third Party: Yes Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL31651 2 R3 Metal Roof Panel Detail signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 2 R3 032GulfLok 16 1S- 32Piywood_Non HV H Z-signed. pdf Created by Independent Third Party: Yes 11651.3 1" 24ga. Gulf Snap 1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Installation Instructions FL11651-R3 II EL11651 3_R3_Netal Roof Panel Detail - signed.pd Impact Resistant: N/A Design Pressure: +N/A/--131.OPS Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 3 R3 1 24GulfSnao 17 IS- 32PI4Wgad HVHZ_sigged_pdf Created by Independent Third Party: Yes 11651.4 1" 24ga. Versal-oc 1" Versal-oc 24ga 16.5" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 II FL11651 4 03 Metal Roof Panel Detall- Approved for use outside HVHZ: Yes slgned.pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-138.5PSF Created by Independent Third Party: Yes Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c. Evaluation Reports clip spacing. Install per manufacturers details. For use in FL11651 R3 AE R I I A';1 4 R3 24Ver3aLoc SR 16.5 15= HVHZ Zones. 32PIy_woo(LHVHZ_ signed.p_df Created by Independent Third Party: Yes 11651.5 1" Versal-oc .032" Aluminum Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.OPSF 1" Versal-oc min .032" Aluminum over 15/32" Plywood Installation Instructions FL1X651 R3 II_FL11651__S R3, Metal Roof Panel Detail- siqned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes http:/)�v-floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2ffr... 4/16/2018 Building Code Online Page 3 of 5 Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6" Evaluation Reports o.c. clip spacing. Install per manufacturers details. For use FL 31 _ I R3 AE FL11651 5 R3 lIn n32VersaLoc In HVHZ Zones. SR 16 15-32PIy_wood HVHZ=signed.odIF Created by Independent Third Party: Yes I 11651.6 1.5" 24ga. Gulf Snap 1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 1I FL11651 6 R3 Metal Roof Panel Approved for for use outside HVHZ: Yes slgned.pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-116.OPSF Created by Independent Third Party: Yes Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" Evaluation Reports o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install FL11651 R3 AE FL11651_6 R3 1_5 24GulfSnap 16 15 per manufacturers detals. For use in HVHZ Zones. 32P1vwood HVHZ-sianed.pdf Created by Independent Third Party: Yes 11651.7 1.5" 249a. Versal-oc 1.5" Versal-oc min 24ga. 16" wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL116$1_J23 II FL11651 7 R3 Metal Roof Panel DeYail- Approved for use outside HVHZ: Yes signed.pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-123.5PSF Created by Independent Third Party: Yes Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12" Evaluation Reports o.c. clip spacing. Install per manufacturers details. For use FL11651 R3 AE FL11651 7 R3 1,5 24VersaLoc 16 15- in HVHZ Zones. 32P1vwood HVHZ-si nq ed.odf Created by Independent Third Party: Yes 11651.8 2" 24ga. MegaLoc Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.SPSF Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use In HVHZ Zones. FLI1651 R3 II F1 11_651 8 R3 Metal Roof Panel Detail - sAned.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports F1J1651 R3 AE FL11651 8 R3 24Versal-oc 18 15- 32Plvwood NonHVHZ-slgned pdf Created by Independent Third Party: Yes 11651.9 24 Ga. Gulf Lok Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail - Approved for use outside HVHZ: Yes sic ned_pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-96.7PSF Created by Independent Third Party: Yes Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76 Evaluation Reports psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8" FL31651 R3 AE FL11651 9 R3 24GuifLok 16 15- fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install 32ftwood NorrHVHZ-signed.pdf per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.10 r24Ga. Gulf Seam Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 1I FL11651 SO R3 Metal Roof Panel Detail - Approved for use outside HVHZ: Yes signed,pdf Impact, Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-93.SPSF Created by Independent Third Party: Yes Other: -93.5 psf @ 18" o.c. Install per manufacturers Evaluation Reports details. Not for use in HVHZ Zones. FL11651_R3 AE FL11651 10 R3 24GuIfSeam 16 1x4_15- 3212IYWood NonHVHZ-sisi_gned pdf Created by Independent Third Party: Yes 11651.11 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-1O8.5PSF Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail - signgdpdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 11 R3 24GuIfSeam 18 IS - 321!lywood NcnHVHZ-sIgi ned.pdf Created by Independent Third Party: Yes 11651.12 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 15/,32" Plywood k httpaI'i vww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwd)gs"c5K%2ffr... 4/16/2018 r ida building Lode Online ,— Page 4 of 5 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.SPSF Other: -108.5 psf @ 12" o.c, fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.PSF Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @ 16" o.c. fastener pattern. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651, R3 II FL11651 12_93Metal Roof Panel Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 12 R3 265vCrimp 15- 32Plywood HVHZ-siyngd_pdf Created by Independent Third Party: Yes Installation Instructions FL11651 R3 II FL11691 13 R3 Metal Ro�gf Panel_Detail- signed_pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 RS AE_FL116S1 13 R3 265vCrimp 15- 32P(y_wood NonHVHZ_signed.pdf Created by Independent Third Parry: Yes 11651.14 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.SPSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions ' FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail - signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 14 R3 265vCrimp ix4 IS - 32Plvwood NonHVHZ=signed pdf Created by Independent Third Party: Yes 11651.15 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161.OPSF Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener • spacing. Install per manufacturers details. For use In HVHZ Zones. Installation Instructions FL11651 R3 II FL11651 15 R3 Metal Roof Panel Detail - signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 ]5 R3 26GuIfLok 16 15= 32PIy_wopd HVHZ signeA_ df Created by Independent Third Party: Yes 11651.16 26 Ga. Gulf Lok Min 26 Ga. Gulf_ Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.SPSF Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL31651 R3 II FL11651 16 113 Metal Roof Panel Detail - sfqned.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 16 R3 26GulfLok 16 15- 32PIywood NonHVHZ-sianed_df Created by Independent Third Party: Yes 11651.17 26 Ga. GuIfPBR Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood Limits of use Installation Instructions Approved for use In HVHZ: No FLIJ§ R3 I FL11651 :L7 R3_Metgl Roof Panel Detati- Approved for use outside HVHZ: Yes g1gned.pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other: -59.25 psf @ 24" o.c. fastener pattern. -154.75 psf Evaluation Reports @ 12" o.c. fastener pattern. Install per manufacturer details. FL11651 R3 AE FL11651 17 _R3 26Gui_fPBR 15, Not for use in HVHZ 32PI wy ood NonHVHZ-si, nq ed.pdf Created by Independent Third Party: Yes 11651.18 26 Ga. GuIfPBR Min 26 Ga. GuIfPBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 II FLII651 18 R3 Metal Roof —Panel for use outside HVHZ: Yes sianed.pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf Evaluation Reports @ 12" fastener spacing. Install per manufacturer's details. FL11651 R3 AE FL11651 18 R3 26GuIfPBR lx4 15- For use In HVHZ Zones 32PI_y-wood HVHZ;signed.pdf Created by Independent Third Party: Yes http://�7- floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs"c5K%2fTr... 4/16/2018 F1'rida Building Code Online Page 5 of 5 11651.19 126 Ga. GuIfPBR Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf @ 12" o.c. fastener spacing. Install per manufacturer's details. For use in HVHZ Zones. Min 26 Ga. GulfPBR over 15/32" Plywood Installation Instructions FL11651 113 II_FL11651 19 R3 Metal Roof Panel Detail- s�ned.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 19 R3 26GulfPBR 15- 32Pywood HVHZ_sianed_pdf- Created by Independent Third Party: Yes 11651.20 26 Ga. GulfPBR Min 26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 11311 FL11651 20 R3 Metal Roof Panel Detail - Approved for use outside HVHZ: Yes signed,pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes Other: -94.25 psf @ 24" o.c, fastener spacing.-151.75 psf Evaluation Reports @ 12" fastener spacing. Install per manufacturer's details. 1`1_11651 R3 AE FL11651_20_R3 26GuifPBR lx4_15- Not for use in HVHZ Zones 32Plywood NOnHVHZ-signed,pdf Created by Independent Third Party: Yes Go to Page 0 idi Page 1 / 2 Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here . Product Approval Accepts: aFa cLf t Credit Card Safe http:�/www.floridabuilding.org/pr/pr_app_dtl . aspx?p gram=wGE VXQwtDq sQFc5K%2f'I'r... 4/ 16/2018