HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGBuilding Code Online Page 1 of 4
SCAN 4.
,} k -
r
BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge Slats & Facts Publications I FBC Staff BCTS Site Map I Links I Search
9a
1i6� pt ;: Product Approval
p
�e' USER: Public User
r
�� Product Approval Menu > Product or Application Search > Application List > Application Detail
fn
GL I FL # FL17022-R7
-- - i Application Type Revision 15
Code Version 2017 20 I OO(
Application Status Approved j
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
08/18/2017v. date reapply 08/21/17
iLL't
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Richard McKuhen
flvalidation@yahoo.com
RECEIVED
AUG 2 7 20i8
ST. Lucie County, Permitting
Richard McKuhen
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
i L
E
rr- -
c
C' �'
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
C_l Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E,
Eel Validation Checklist - Hardcopy Received
Certificate of Independence
FL17022 R7 COI FL 17022.1 5 V CRIMP ssrodf
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
s://floridabuilding:org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rM... 2/15/2018
Building Code Online
Page 2 of 4
Product Approval Method Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
Summary of Products
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (R6)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 Ii FL 17022.1 5 V CRIMP ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E, 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.Ddf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes .
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (R6)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 iI FL 17022.2 5 V CRIMP 0.032 ALUM ssr.Ddf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other. Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
assembly in compliance with the installation method listed in
ALUM ssr.ndf
this report and applicable code sections of FBC. Refer to
Created by Independent Third Party: Yes
manufacturer's installation Instructions.
17022.3
3 - "1.5" Mechanical Seam" (R5)
1.5" rib height, 16" wide, 24 gauge steel, standing seam
roof panel mechanically attached to 15/32" plywood or wood
deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 TI FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24ga ssr.DdF
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
the Installation method listed in this report and applicable
seam 24ga ssr.Ddf
code sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 it FL 17022A MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssr.Ddf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.Ddf
the Installation method listed in this report and.applicable
code sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
Instructions.
17022.5 15 - "1 in. Nail Strip" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood
deck with fasteners.
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.Ddf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.5 1.0 NAILSTRTP ssr.Ddf
Created by Independent Third Party: Yes
/floridabuilding.org/pr/pr_app_dtl, aspx?param=wGEVXQwtDgv2aBQpHpQQe6rM... 2/15/2018
Building Code Online
Page 3 of 4
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
Instructions.
17022.6 16 - % In. Nail Strip" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC.'Refer to manufacturer's installation
instructions.
1" rib height, 16" wide, 0.032" -aluminum, standing seam
roof panel mechanically attached to attached to 15/32"
plywood or Wood Deck with fasteners,
Installation Instructions
FL17022 R7 11 FL 17022.6 1.0 NAiL STRIP 0.032
ALUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.6 1.0 NAiL STRIP 0.032
ALUM ssr.odf
Created by Independent Third Party: Yes
17022.7
7 - "1.5 in, Nail Strip" (RS)
1.5" rib height, 19" wide, 26 gauge steel, standing seam
roof panel mechanically attached to 15/32" plywood or wood
deck with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 iT FL 17022.7 1.5 Nail Strip 26GA ssr.ndF
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.ndf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.8
8 - "EMAX Rib" (115)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 177022.8 EMAX Rib ssr,Ddf
limitations of use. Install the assembly in compliance with
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.9 9 - " PBR MAX" (115) 26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022,9 PBR RiB ssr.odf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf
limitations of use. Install the assembly in compliance with Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
flack Next
Contact Us :: 2601 81a1r Stone Road. Tallahassee Fl, 32399 Phone: 850-487-1024
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
rM `-1-Wilr iCred -s-v
Credit Card
Safe
Aloridabuilding.org/car/pr app dtl.aspx?param=wGEVXQwtDgv2aBQpHDQQe6rM... 2/15/2018
� J
Building Code Online
Page 4 of 4
app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rM... 2/15/201 S
,tau bw roma unve
Palm City, FL 34990
j772)872-8034
Co ' pliant with Florida Building Code 2017 (61" ed.)
Cor pliant with Florida Product Approval Rule # 61G20-3
Cor, pliant: Keystone Certifications
Pro uct: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Cor'osion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/1 " min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
req ! irements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
per trate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to r eet requirements)
Un I",erlayment: To be compliant with FBC Sec. Chart 1507.1.1
Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Inst
If Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DES
N PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
428 PSF
RON
I SPACING
16" o.c.
16" o.c.
8" O.C.
6" o.c.
FAS
'IENER SPACING (ALONG Panel width)
12" o.c.
12" o.c.
12" o.c.
12" O.C.
FAS
IENER SIZE
1 #9
#10
#10
1 #20
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580-06 & 1897-041 Test Report IIES93.01-450-18 05/02/14
Test _ Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQ iVALENCY--UL 1897-04 is equivalent to test standard UL 1897-1� *Design pressure margin of safety 2:1
fitr►rt
Lock Bowden, P.E. does not have, not will acquire a financial in�� �'',������in a �c �,q m, f�+facturin or distributing products
q�'3`0r1 ��, gPZ!� g g
uncle' this evaluation.
Lock Bowden, P.E. is not owned, operated, or controlled by any colnparNprnbfia fat or distributing products under this
repo , . f
''r.. • r.GS i T� � �4�
�,/ 7
�n a
Limitatior
1. Unde
2. Minir
3. Prod
i 4. Engii
5. Fire I
6. Supr
Struc
7. This
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel -Details
iyment to be compliance with current Florida Building Code (FBC)2017 6th ed.
m slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
is are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
Bring analysis for "project specific, approval by local authorities w/jurisdiction is allowed by other registered engineers.
ssification is not part of this acceptance. Shear diaphragm values are outside this report.
t framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
ral Loading.
Sort does not imply warranty, installation, recommended product use outside of this report.
Fasteners-
#9 x 1-1/2"MIn. -roar par7ableA"for Row
Spacing and Design Pressures
Hex Washer Head Wood Screws
Deek:
-16/32' or greater Plywood, or
-Wood plank
14-
1�'
XF
OPTIONAL STRIATIONS
Nominal 12"
O.C.
Panel Profile
Nominal 12"
O.C.
5-V Crimp Roof Panel
Fasten
9 X 1-1/2" Min. or #10 x 1-1/2" Min. per
—fable "A" Hex Washer Head Screw
Panel Spaced 12" o.c. across the Panel 1Mdth
Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
-Wood plank
F� orida Building Code Online Page 1 of 2
C� 9iJ .U�4x�
5
r BCIS.Home I Log In I User Registration Hot Topics I Submit Surcharge Slats & Facts
Publications FBC Staff I SCIS Site Map I Links I Search
ProductApproval
USER: Public User\rC
SCANNED
Product Approval Meru > Product or AonliCation Sepreh > Apnlicalinn List > Application Detail
��
By
Lucie COM-ly
FL # FL17322-114
Application Type Revision
Code Version 2017
I ��
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Atlas Roofing Corporati
2000 RiverEdge Parkw ..
Suite 800 LE,
Atlanta, GA 30328
(770)946-4571
mcollins@atlasroofing.com
Meldrin Collins
mcollins@atlasrooflng.com
Roofing
Underlayments
RECEIVED
AUG 2 7 2018
ST. Lucie County, Permitting
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Zachary R. Priest
the Evaluation Report
Florida License
PE-74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
Locke Bowden P.E.
Ili Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL17322 R4 COi ATL14001.4A 2017 FBC Eval Report Atlas
Underiavments final.ndf
Standard
ASTM D 1970
ASTM D 226
ASTM D 2626
ASTM D 4869
ASTM D 6380
TAS 103
TAS 110
UL 1897
Year
2015
2009
2004
2016
2003
1995
2000
2012
://floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsRyNwiNWDrY8P... 3/20/2018
Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/30/2017
Date Validated 10/03/2017
Date Pending FBC Approval 10/04/2017
Date Approved 12/12/2017
Summary of Products
Page 2 of 2
FL #
Model, Number or Name
Description
17322.1
Atlas Underlayments
For use in steep slope roofing
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL17322 R4 TT ATL14001.4A 2017 FBC Eva[ Renort Atlas
Underlavments final.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
Created by Independent Third Party: Yes
Evaluation Reports
FL17322 R4 AE ATL14001.4A 2017 FBC Eval Report Atlas
Underlavments final.pdf
Created by Independent Third Party: Yes
17322.2
Fabral All Purpose High -Temp
ASTM D 1970, SBS modified, self -adhering underlayment
Underlayment
with fiberglass mat reinforcement and a poly-fabrlc surface.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL17322 R4 ii ATLI4o01.4B 2017 FBC Eva[ Renort Atlas
Fabral Underlayment final.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Other: See evaluation report for limits of use.
Created by Independent Third Party: Yes
Evaluation Reports
FL17322 R4 AE ATL14001.4B 2017 FBC Eva] Report Atlas
Fabral Underlayment final.od(
Created by Independent Third Party: Yes
pack Noat
Contact Us :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: 650.487-1824
The State or Florida Is an WEED employer. Coovdaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility -Statema :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mall to this entity. instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.407.1395. *Pursuant to
section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S, must provide the Department with an email address it
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. if you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine It you are a licensee under
Chapter 455, F,S., please click hnrg-.
Product Approval Accepts:
0 o a eCf- a
Credit Card
Safe
/floridabuilding.org/pr/pr app_dtl.aspx?param--wGEVXQwtDgsRyNwiNWDrY8P... 3/20/2018