EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
'26 GA. 5V-CRIMP PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORA PRODUCT APPROVAL
FL 14645.4-R3
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (918) 493-3568
SCANNED
By
Sf. Lucie CORN
This report consists of
Evaluation Report (3 Pages including cover) ItI1eieeaee
Installation Details (1 Page) �0%%-'SoCKAL�9
� ss
Load Span Table (1 Page) �`o•�QP.��G
4 E N gF•�?'y,� ooB
ro�
b No 62240 a
Report No. C2182-4 ®, STATE OF .
. p . 0.
Date: 9.9.17 <st�`s • o R
ALE
e
`t C>(-7
ff
FL 14645.4-R3
C2182-4
9.9.17
Page 2 of 3
Manufacturer:
Metal Sales Manufacturing Corporation
Product Name:
5V-Crimp
Panel Description:
24" wide coverage with (5) 1 /2" high ribs
Materials:
Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description:
Min. 7/16" thick OSB or min. 15/32" thick plywood or min. 3/4" thick
wood plank (min SG of 0.42) for new and existing constructions.
Designed by others and installed as per FBC 2017.
Deck Attachment:
8d.x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum)
in the plywood field, and edges. Designed as per FBC 2017.
Underlayment:
Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Slope:
1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
:Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2) 172.5 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall :be of sufficient length to penetrate through the deck a minimum
of 318" and installed as per Metal Sales current installation procedure.
At panel ends @'6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance. with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in LL 1897-12.
Code Compliance: The product described .herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
directory or ASTM E108%UL790 report from an accredited laboratory
foftatings of this product.
Supporting Documents: UL580 & 1897 Test Reports
PRI Construction Materials Technologies
MSMC=017-02-01, Reporting Date 9/20/13
FL 14645.4-R3
C2182-4
9.9.17
Page 3 of 3
computed using rational analysis prepared by a Florida, Professional j
Engineer or based on Metal Sales load span table. This evaluation 1
report is not applicable in High Velocity Hurricane Zone. Fire !
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
PANEL OVERLAP
5V-CRIMP
SEE DETAIL 2 SEE DETAIL 1
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
FASTENER AT PANEL FIAT
REQUIRED FOR PANEL
ENDS ONLY.
MINIMUM ATTACHMENT:
8d x 2.5" LONG RING SHANK NAIL
UNDERLAYMENT SHALL BE INSTALLED OR #8 x 2" LONG WOOD SCREWS
AS PER MANUFACTURER'SINSTALLATION SPACED ® 6" O.C. IN THE FIELD
GUIDELINES & AT EDGES
MIN. 2X- WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" O,C,
TYPICAL PANEL INSTALLATION X—SECTION
5V-CRIMP
MIN 26 GA.
PANEL FASTENER PER UPLIFT
LOAD TABLE
d
0 0
u N
CD co
=No
zs ii
2 M J 00
y x o
V) (nJ
a
to
a
VOSB
I=FNERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.019"). EFFECTIVE COVERING
IF
'L
=
°
" b
om
^<
UNDERLAYMENT 7/16" THICK (MIN.) OR
�
q THICK (MIN.)
DETAIL I PLYWOOD 15/32
WIDTH OF PANEL = 24".
3. THE ROOF PANELS SHALL BE IN OVER SHEATHING &STRUCTURE AS
Q
I
z
SPECIFIED. ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
n
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
-
N
m
m
9-16 OR �10-14 WOODSCREWS
'AT
ITH SELF. SEALING WASHER'AT
ARE GREATER THAN THE. DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
OCCURS BETWEEN THE MINIMUM
&
z
R
MAXIMUM' SPACING OF 36"
BUILDING CODE. IF A DIFFERENCE
REQUIREMENTS OF IE CODE SHALL
�TOHWI
S
6. RAFTERS/JOISTS/TRUSSES MOST BE DESIGNED TO,WITHSTAND WIND LOADSAS
MIN 2RIMGA
REQUIRED FOR EACH APPLICATION AND ARE THE OF OTHERS.
UNDERLAYMENT \--OSB 7/16" THICK (MIN.) OR sneET i
DETAIL 2 PLYWOOD 15/32THICK (MIN.) OF
METAL SALES MANUFACTURING CORPORATION
5V-Crimp. Uplift -Loads
(Min. 26 ga.)
Description
Fastener Spacing
along panel length
()
Allowable Uplift
Load
(psfl
Coverage width: 24"
Panel Fasteners
99-16 or #10-14 hex head
wood screws with sealed
washer
6
172.5
g
_ 120,0
15
72.0
18
60.0
21
51.4
24
45.0
27
40.0
-- 30
36.00___..
32.7
33
36
30.0
Notes:
L The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 14645.4 and Metal Sales current installation procedure.
3. Three or more spans condition.
1216 N Lansing Ave., Suite C
Tulsa, Ok 74106.
918 492 5992
'gtiaaseleteee��ee�
SO.CKgL� °'ae
.N s,
�4LQ2��•�'�GENSF••O'9 fss
• No 62240
ell � • n •. � 4
�� :• STATE OF 44/
'dAN
0
fi!
Bala Sockalingam, Ph.D., P.E.
FL 62240