This OA is being issued under the applicable �� regulations governing the use of construction materials. The
docui i I ientation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be
used i Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This i OA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have.this
produ ll,,t or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
mann r, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspe d the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it i determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requ'" ments of the applicable building code.
This I�roduct is approved as described herein, and has been designed to comply with the Florida Building Code
inclu ng the High Velocity Hurricane Zone of the Florida Building Code.
DES' RIPTTON: Ultra HT Wind & Water Seal` High Temperature
LAB LING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
state ent: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
KE WAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in thell4pplicable building code negatively affecting the performance of this product.
TER ATION of this NOA will occur after the expiration date or if there has been a revision or change in the
mater als, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sa es, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of thi' NOA shall be cause for termination and removal of NOA.
ISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its
INSlCTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall a available for inspection at the job site at the request of the Building Official.
This � OA consists of pages 1 through 3.
The s bmitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 13-112M6
Expiration Date: 03/27/19
Approval Date: 03/27/14
Pagel of 3
0
1G COMPONENT APPROVAL
Roofing
;gOry: Underlayment
SBS
This acceptance is for Ultra HT Wind and Water Seal? High Temperature roof underlayment as described in this
Notic of Acceptance, for use with approved prepared roof assemblies.
TRAIE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
Ultra T Wind and Water 36" x 67' rolls ASTM D 1970 45-mils thick (nominally), self adhering,
Sealf' gh Temperature membrane composed of a white, non -slip cross -
laminated polymer film, laminated to a
rubberized asphalt adhesive with a split release
liner.
TC(
ACTURING LOCATION:shocton, OH
EvInIENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI C M ilnstruction Materials Technologies, FM-039-02-01 ASTM D 1970 08/15/13
Inc.
APP OVED ASSEMBLIES:
Deck�IType 1: Wood, non -insulated
Deckloescription: New construction or reroof minimum 19/32" or greater plywood or wood plank.
Syste';' E(1): Anchor sheet mechanically fastened deck, membrane adhered.
I •
Base heet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626 with a minimum 4" head lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" -o.c. at the laps and
jtwo staggered rows 12" o.c. the field of the roll.
Mem I rane: One or more plies of Ultra HT Wind & Water Seal` High Temperature underlayment with a
minimum 3" side lap and 6" end lap. Place the first course of membrane parallel to the eave,
rolling the membrane to obtain maximum contact. Remove the release membrane as the
i
membrane is applied.
Surf ing: Approved for mechanically. fastened metal roofing, asphaltic shingles, wood shakes and shingles,
quarry slate roof assemblies.
NOA No.: 13-1125.06
MuaMi nape CC NW Expiration Date: 03/27/19
Approval Date: 03/27/14
Page 2 of 3
I •
I
i
1. Fire Classification is not part of this acceptance.
2, his acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
pplicable building code. Ultra HT Wind & Water Seal? High Temperature underlayment shall be installed in
trict compliance with applicable Building Code.
3. Ultra HT Wind & Water Seal` High Temperature underlayment may be used in mechanically fastened metal
oofing, asphaltic shingles, wood shakes and shingles, quarry slate roof assemblies. Ultra HT Wind & Water
eal High Temperature underlayment shall not be used as roof tile underlayment.
4. �Jltra HT Wind & Water Seal` High Temperature underlayment shall be applied to a smooth, clean, and dry
surface with deck free of irregularities.
5. iltra HT Wind & Water Seal'` High Temperature underlayment shall not be applied over an existing roof
membrane as a recover system.
6. Ultra HTVind & Water Seal=" High Temperature underlayment shall not be left exposed as a temporary roof for
longer than 30 days of application.
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
pecific prepared roofing products.
S. Ultra HT Wind & Water Seal? High Temperatureunderlayment may be used with any approved roof covering
Notice of Acceptance listing Ultra HT Wind & Water Seaff High Temperature underlayment as a component
part of an assembly in the Notice of Acceptance. If it is not listed, a request may be made to the Authoritylaving Jurisdiction (AHD) or the Miami -Dade County Product Control Department for approval provided that
ppropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
esting results.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions. For ridge applications, center the membrane and roll from
1 e center outward in both directions.
10. oll or broom the entire membrane surface so as to have 100°lo contact with the surface, giving special attention
o overlap areas.
11. i lash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
otice of Acceptance and applicable Building Code.
12. Ml
protrusions or drains shall be -initially taped with a 6' piece of underlayment. The flashing tape shall be
ressed in place and formed around the protrusions to ensure a tight fit. A second layer of Ultra HT Wind &
Water Seal` High Temperature underlayment shall be applied over the underlayment.
13. Ik1l products listed herein shall have a quality assurance audit in accordance with the'Florida Building Code and
ule 61G20-3 of the.Florida Administrative Code.
14. membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control
A7�proved or the Miami -Dade County Product Control Seal as shown below.
END OF THIS ACCEPTANCE
NOA No.: 13-1125.06
Expiration Date: 03/27/19
Approval Date: 03/27/14