HomeMy WebLinkAboutPRODUCT APPROVAL2160 SW PdMa Drive
Palm City, FL 34990
Florida Product Approval # 17022.5 1" Nalilstrip
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
m Compliant
Keystone Certifications
Compliant: I I I I
RECEIVED
AUG 2, 81017
Prod L Ct: I" Nallstrip 26GA,Steel Roof 'Panel FBC Sec. 1507.4.2
11 I I I Permitting me,
Yield strength: 50 ks! min Attached to min. 15/32" St 'tDepa plywood or Lucie Depart
me,
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1„
Corrosion Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1: #10 x V (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottof,,.n. 0 support.
Adhesive/Se.alant Bostik 915"1 Chem -Chalk one component, polyurethane adhesive with
3/iVcontinuous; bead` application along base of male rib vertical flange at each panel
t
seam.;ST. LUCIE COUNTY BUMPING DIVISION
Underlaymentjo be compliant with FBC Sec 1S07.1.1 'REVIEWED FOR COMI�r 14
Rr VTF\MED BY
DATE My, lb
Slope: Shall be in compliance with FBC Sec. 1507. PLANS -ANd PERMIT ST bt KEPT ON 30B
SITE OR NO INSPECTION(S) WILL BE MADE
' eta"
InstallI I S.- ,Table
METHOD 1_
'!METHOD
DESIGN
OSF Main field
f 97.25 PS F
w.-'86
_?"ter,
FASTENER SPACING
W 0 It.
SEAM ADHESIVE
Not required
3 1 6IV continuous bead
----------
(see details
M
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580 66 & UL 1897-04 TEST REPORT D8133.01-450-18
06/30/15 Specimen #1 & #2
,q!�O� A_Aj��7_
EQUIVALENCY ��_qQtp.Ti�sQt ar U -1?�;
5.54 rgmargjn,.Qf afety,2.,.jj
Certific ate of independence:
Locke Bc den, PX. does,not have, not will acquire a,financial 1 0 4 . I' V �com
, `0�any manufacturing or distributing products
'VON ti 49
under thi's evaluation.,
S
&
Locke BJwden, P.E. is not owned, operated, or cointroll 41 h.0.0uri6r, or distributing products under this
.2
repo i
seal
STATEOF
_dMo
FIL©
1. Underiayment to be compliance with current Florida Building Code (FBC)2017 6"' ed..
2. Mini num slope to be compliant with Florida Building Code 2017 6"' ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Eng leering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Firei classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Sup ort framing in compliance w/FBC 2017 Uh ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
Panel Profile
16" ox.
3/4"
J-
Deck:
-15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3/16" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1" Min. per Table "A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
or greater Plywood, or
- Wood plank
P=fcnor
Isometric View
rv1 mcu HJu
Apply 3/16" Bead Bostik 915TM Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table "A")