HomeMy WebLinkAboutMOBILE HOME FOUNDATION PLANS2 - V2 - I - VS' ry 2 X e P.T. W/ IOd LUG-26 GALY. W4-I0d
I GALY. OR S.S GALY. OR S.S. NALS NASA TO HEADER 14404 -
; BOLT (6) o b' O.C. STAGGERED GALV, OR 8A. HAILS TO JOISTS Z O
IL m
-4-MR-SFUCE ON
ARE NEXT TO PILING ALL 2 PLY NON_ U N
USE (S) 16d GALY. OR CONTNIIOIA EEAMS
S.S. NALS NAILED TO W/ 2 ROWS 104 GALY. _3 Q
PILNG (3) Ibd NAILS OR S.& NAILS. e°
TOE NAILED TO BEAM O.G. ?
LLO OF LUS-26 z a
6x6 P.T-PILNG_.t-
U N
J
X B P.T. FLOOR z
JOISTS . Y O.C. F
c
F
I I/2" DEGIGING
--�2-2 X S P.T. RIMBOARD NAILED
2 X B P.T. JOISTS
w/2 ROWS IOd. FASTEN TO EACH
PILING w/ 2-1/2" OR 1-1/8" THROUGH BOLT
4 X 4 P.T. PILING
Gorvnd
a•°a.'
D
e•S°•" IS.. Concrete Cylinder
Centered on 4 x 4 poet
�. ° �e
s°°, • ° embeded 3611 Into so[[
� °
•i D
NOTE:
Flood Vents Required
In skirting o 45 O.G. min.
eeeeeeeeev0000
�eeee c� LEE S
No 6661/7, 7���
v
(L8V �'
• STk •�
s C) A.
4 0 R `Q P N
oS "1111 O fV A„ s's�eee�
James Lee Smith /1.E.
11/21. HAND AIL
IN
NOTE: ALL HANDRAILS CONFORM
TO FBG.SEG.1001.5.3
36" x 3611 landing at
(2)X2X8 "
- PLATFORM
DOUBLE TOP
e 32" O.G. t ENDS
\ `
BTRNSGFR TO �ry-1
KICKER PLATE ill
�Ms.
I115RRZIII /
RAOR
III���TTT
/Ib' DIAM. X 3 V4' TAPCONS a 24' O.G. 'ATFNDS-
2 X -..- KER
TREAD
TREAD
MAXIMUM: 11.5"
MINIMUM: 10"
RISER
MAXIMUM: 1.5"
MINIMUM: 6.15"
MAXIMUM TOTAL VARIATION
BETWEEN ALL RISERS: 3/5"
THE FOLLOWING MUST BE TRUE:
(2) RISERS a (1) TREAD - 24 - 25"
Railin26 to be designed to resist
a pef, load any
S
at nplF
STAIR DETAIL
point
point and In any direction and S
aN ditratedrection
�TYPIGAL
N.T.S.
for in -fill component and 40 pef, for
stair live load
M
❑❑O
o❑
o0 00
FIR,
❑L7
❑[i ❑
o❑�
❑o
E0
On
❑o
o❑
o❑
Elmo00
0❑
❑o
MCI
MCI
00 00
❑off
moo❑
I V 11
. I'�1!�P.�I'�
I I I I I II
�'; w �I�� �I�►Wl�pl'
III 1
wl'�'�I� �I'�'� �PaP�'�1'�� �'���'� � �►'� ��
- o z
z =—� :� - 3 Q— —p U
boo
duo g 3•
Uzr>
Qis�A
�uj •� c�v0
7iI-i!! (o
Q NW ° Q
I� N
; a
W
l_ROU�
wtD
Z
L1UaNO
U
3-4 L 7-0
awp -
=W63
V
=U Tmr;m o
CL�QLI
FWK
�ua.pa=3i
0MAW.I1�i�0-1
7 LLQ
,U,�, aLL a12Q Qw
Z�0
�Qu-Q
'YpZ wOQO
125—ZEUOIX
L L
Q nn�
(L
o� a
O E
U 0
Q) cil
J
0 i
U-
m m
O
Ili
a Q)
d) is t
V
us
Q)
O
wJ
F—
MM
381-0ii
MM
t- — — — — — — —
— —
— — — — — — — — — — — — — — — — — — —
— —
— — — — — — —
O
■ ❑
❑ ■
-----------------------------
❑ ❑ ❑ ❑ I
■ ❑
❑ ■
❑■
■❑10101
10101❑■
■❑ II
Ll
Grose Bracing
I
I
I
I
I
I
I
I
O
O
I
I
I
I
I.
_ _ _ _
r Longitudinal Bracing
I
I
I
I
_ _ _ _ _ _ _ _ I
I
I
1
I
_ _ — _ I
p
I ❑■
El
❑❑ ❑❑ I
❑■
■❑ II
■❑
■❑
10101 10101■❑
El .I
L— — — — — —
— — — — — — — — — — — — — — —
— — — — — — -j
I 1 II
-8
I II
(o -O
I II
6 -8
i II
3 -4
I II
6 -8
I II
-O
I II
-8
I II
1-4
I II
1-4
I II I 11 11
1-4 1-4 1-4
I iil
1-4
40'-0"
James Lee
r— — — — — — — — — — —
I I I I I I
I I I I I
I I I I I I
I I I I I
I�I rebar
I I I I I I plfver "v'
I I I I I (2) 112" x 11
Anchor
I _
I I I
I I I I I
I I I I I I
l I I I
I I I I I I
l
I I I I I I
I I I I I
I I I I I I
L— — — — — — — — — — — J
— - r— « i ypicai i3race i connection l,etail
ithr/ D.E. -
. J
Indlcatee filled cell
w/ (1) 05 rebar
epoxied 5" Into footing
1 extended 12" above
Footing w/grout filling
to top of pier
❑ ❑ Indicate- 1 xx 16 c1'1U
Pier (dry stack)
Indicates Oliver Bracing
Complies. w/F5C for
160 M.P.H, vult E
124 M.P.H. vasd
MM_MM
100,44 uu
MN .. An
'P
�� 81 I 00 I
Q
�
I
I
II I I
I I I I
`i
I
■❑ ■o
o■ o■
I I I I
m
I I I I
I I I I
I I I I
I I I I
❑❑ I I ❑❑ I
Y
I I I I
I I I I
Q
Y
❑❑ I I ❑❑ I
oo I
I I I I
I I I I
I I I I
I i --- r------------- 1------ - I
■� o■ I I
o■ No: l
II I I II
ON I I Mojl
=
I ■o I I o■ I I--------------
d)
}� � UN
Z
_1
zOa
N0.
p�
p o
pa9�
U Z r
U 1 0
uu a
Tu LL F n 0
O-
TO
ZOUZ
t
w`�°za
�pu0'O
1111
i
Z y yQ
Wiil?�A
o
u �1L3N�-N
p Q 3— 1= Y L1 1L LL to e
QQlu+ =U a W n1U
'•.'i =W- LL3Ul
YLLO�ay QD
m ..........
NS''•. °'� N�g� u0QI�rz Uli
No 36 7 �aLL ��aZo��7a
4
•n
STA
/u F 0
d • ` O 11=
14
`/S/oNAt- G`�i0�® u r
�dIs
®l818111®4��®
u a
>
12'-0" m _j O J N � -i �
r �
Q] ¢
■❑ I I ❑■ I �uIn M oi-
N s�
M-2