Loading...
HomeMy WebLinkAboutSEAWALL PLANS AND PHOTOS�,> T 00 MN. SETBAC EQ. -71 iONT IDES f > RECEIVED =G1R SIDES i "RI ' ( t AG. UG ' ®�'� faTECH. County, rmitting e ST. Lucie n! o o w M a rn W Ale ^ i o m "-3 r m + ai �V . ail "Id r:r,iaz9 3S. _L C) .. .. (D - CC 0 G cn CD N CD Cj)CD i ...- - 0 CD s 0 q. Ci. fk T p �� V C ' P� yeuuePst � F 4 tlfmu n am r CD w �-- 0 CD Ul oc). 3'= Sli}ai Ul � I s 6e ! x � ,•' "D yam p®� P COD ! o C" Wall �0�% -¢ Q C� • i� ros s rr,�' I + ? � I °s its, r.0or v .y r Permit Number 4 r 56-0366445.001,002-EE b b A o p Southeast District y c ya Line NOTES: 1. King (vertical) pilings: min. 4, max. 5 2. Batter (angled) pilings: min. 3, max. 5 3. Concrete 5000 psi 4. King Wor batter pilings to be field located. 5. Pilings to be final hammer driven to a min. capacity of 5 tons each 6. Existing seawall and components to remain. Waterbody: t . Pro osed `• . •Y Artificial canal off King Pilings _ max. 10'± OC xisting Seawall of the Indian River (location may to Remain Width: varies 100'# vary in field) •:y'; Pro osed concrete 3 '± Walterick Residence cap 28"x14", 10701 S. Ocean Dr., Lot 835 Concrete panels 8"x12'x10'. ".. L 835 Jensen Beach, FL 34957 A rox. MHW/MLW �t'• typ.Proposed Batter Pilings Property Line max. 10'± OC (Angled 4:1± @ panel midpoint) (location may vary in field) Proposed Walterick Residence Proposed Plan View Sea Wall A $a°d ®/�/ a a . FortP ° Roa �f4�7 b,?' ;spy Wilco Construction, Inc. Date: 6/6/18 (772)460-6928; FAX(772)460-6929 NOTE: 1. Concrete to have a min. Compressive Strength of 5000 psi @ 28 days. 2. Install new concrete seawall directly in front of existing seawall, within 18" face to face. 3. Pilings final hammer driven to a min. of 5 tons each 4. Pilings to be 12"x12" prestressed concrete up to 20' length. 5. Plat width is 35't 6. King &/or Batter pilings may be field located, as needed. r-Liftina Hooks #5 Bar He and The work specified herein has been designed and all work shall be in accordance with the 2017 Florida Building Code (6th Ed.). All codes reference herein are per the latest adopted edition. 5 PCs 14"x28"+/- Concrete #3 Ties #5 —BarCap Cont. @2' O.0 New Concrete Panel 28„+/- (8" thick x 10' wide x 12' long) 4"+/ King Pile 12"x12" ri t prestressed t . (Vertical at panel seams, max. 10' OC Backfill Between _ r Existing Wall & New Wall ,'• Panels i f Min. 3'+/- mbe for P neI y �. `•i <18" (face Walterick Residence to face) 10701 S. Ocean Dr., Lot 835 35'+/- New Jensen Beach, FL 34957 Concrete Cap/Wall oB ENi-j�0 �tb .f. 28�+/- 4 c 4, At Permit Number y 4 r 56-0366445-001,002-EE King pile @ panel seam t p (vertical) p Southeast District y d ~ Y� to col 8tvae' Cross Property (Lot 835) Section after Pile (angled 4:1+/- anel)(max. 10' OC) raNw CANAL BOTTOM 50% min. penetration for pilings 12"x12" Concrete Pilings 2' OC ater pile @ panel midpoint (angled 4:1+/-) pile @ panel seam (vertical) Expanded iew King Pile min. 3" oncrete coverage ver rebar Pc 8rf /_ #5 rebar 3 rebar ties `' 14" = @2' OC 5 dowel with std. hook epoxy- 12"x12" King .' set min. embedme Conc. Pill 6" 2 pc, per pile Expanded m . T. Batter Pile c crate overage verrebar pcs. 8" f /—r5 rebar 3 rebar lies 14" @2' OC .••' 5 dowel with std. r; * hook epoxy- 12"x12" Batter set min. embedme Conc. Pill "• `' 6" 2 pc, pe/pile Rq�661;'�.ab, (772)460-6928; Fax (772)460-6929 Rnie4lh4 rE�9 + a e 'i e �4�a`l n Road! . a, e 2 Fort Piees947 .,•5'��' Via,. Scale: Dim