HomeMy WebLinkAboutPRODUCT APPROVAL - ROOFINGP
BCIS Home - Log In User Registration Hot Topics ,l. Submit Surcharge j Stats & Facts I Publications ? FBC Staff 1 BCIS Site Map Links Search
S'
i Product Approval
r, USER: Public User
Pro u_ dpproval M.^nu > Product or Applicatiar: S::arch > application. Usz > Application Detail vCApN�l�l
FL # FL17443
43 l�
Application Type Revision
Code Version 2017 V
Application Status Approved
Comments
Archived
Product Manufacturer J A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE, FL 34982
(772)466-4040
kylewhite228@aol.com
Authorized Signature Kyle Taylor
kylewhite228@aol.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/23/2023
Validated By Zachary R. Priest, P.E.
.,o Validation Checklist - Hardcopy Received
Certificate of Independence FL17443 RI COI FL 17443 J A Taylor 2017 Code Eval Report with Details
RSSS,p_L
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL580 2006
Equivalence of Product Standards
Certified By Am lu W IN F
. '6
Sections from the Code _ L �'�
i
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL #
17443.1
Method 1 Option D
01124/2018
02/14/2018
02/17/2018
04/10/2018
Model, Number or Name ; Description
5 V Crimp 1 26GA 1/2" rib height over 15/32" APA plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-129.25
Other:-129.25 @ 6" o.c. -69.25 @16" D.C. margin of safety
2.1 with 24" max. coverage install per manufacturers detail.
Not for use in HVHZ.
17443.2 1 VICTORIAN CRIMP SHINGLE
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-105
Other:-105PSF margin of safety 2:1. Install per
manufacturer's details and in compliance with FBC 2017 6th
ed, Not for use in HVHZ.
Installation Instructions
FL17443 RI II FL 17443 3 A Taylor 2017 Code Eval Report
with Qetails RSSS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 RI 8E FLI7443 3 A Taylor 2017 Code Evan Re opt
vith Details RSSS.pdf
Created by Independent Third Party: Yes
26GA 1/2" RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER
CDX/APA 15/32" PLYWOOD
Installation Instructions
FL17443 RI II FL 17443 3 A Tay or 2017 Code Eval Reps
with Details RSSS.p.0
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FLIZ443 RI AE FL 17443 3 A Taylor 2017 Code Eval Repor
with Details RSSS.pdf
Created by Independent Third Party: Yes
® M
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Qpy�,ght_2007.2013 State of Florida.:: E Wacv Statement :: AccessibilltyStatement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a publiarecords request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please dick here..
Product Approval Accepts:
® Ek M
Credit Card
Safe
302 Milton
Fort Pierce, FL 34962
--- _ _ _ _ (772) 466-4040
Comp1 ilant with Florida Building Code 2017 (611 ed.)
Comp, oant with Florida Product Approval Rule # 61G20-3
Comp rant Quality Assurance Program: PRI CONSTRUCTION MATERIALS TECHNOLOGY
FBC 5 dons: 1504.3.2,1507
5V Crimp thru fastened W rib at each panel edge and 1 fastener in the center of the panel, 24" net coverage, 26GA ASTM,
A79i, G-50, AZSS, .018, SOksi min. over min. iS/32" thick CDX plywood deck. Corrosion Resistant fastener #9-15 HWH with
seal ing washers, metal to wood connections with fastener length to penetrate 5/16" thru substrate. Fasten along the crown
oft a rib in the center of panel and along the lap. First. fastener to be within 3" of panel edges. Min. SDx2" annular ring shank
nail spaced 6" O.C. reroofing, with less than 19/32" plywood (min. iS/32"), this attachment is to be used in addition to.
ex i Ing attachment. Deck slope 2:12 or greater and shall be compliant with FBC 2017 6T" ed'. Underlayment: See FBC 2017 61"
ed.,', Sec.1507 Table 1507.1.1
**Design Pressure:
Spacing:
-69.25 PSF
16" O.C.
-129.25 PSF
6" O.C.
266'i� ASTM A792, G-SO, AZ55, .018, SOksi Victorian Crimp Shingle over 15/32" CDX/APA:Plywood attached to roof trusses.
Corrosion Resistant Fastener #10 x I" Zinc plated, MTW Pancake Head, installed at 2 per panel into lock seam. Panels applied
with) S2 exposure, adjacent shingles inserted into lock seam of previous shingle. Deck slope 2:12 or greater and shall be
com liant with FBC 2617 67" ed. Underlayment: See FBC 2017 6T" ed., Sec.1507 Table 1507.1.1
"Design Pressure:
-10S PSF
J **DESIGN PRESSURE INCLUDES A SAFETY MARGIN OF 2:1
Reference Data:
TEST RE 7ORTS
Hurrica a Test Laboratory (TST 1527) #0224-0501-06 TAS 125 (UL 580-941)
PRI Con,;truction Materials Technologies (TST-5878) NFAE-023-02-01 UL 580.06/UL 1897-042
1. UL 58 -94 test standards are equivalent to UL 580-06 test standards.
2. UL 18 7-04 test standards are equivalent to UL 1897-12 test standards.
LimitatioPS:
1. ,Jnderlayment to be compliance with current Florida Building Code (FBC)2017 6T" ed.. see Chart 1507.1.1
2. ,Winimum slope to be compliant with Florida Building Code 2017 6« ed., and per with Manufacturer's installation reference.
3. roducts are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered
S. , ire classification is not part of this acceptance. Shear diaphragm values are. outside this report.
6. upport framing in compliance w/FBC2017 6m ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Certifi to of independence:
Locke Bo den, P.E. does not have, not will acquire a financial interest in any company manufacturin��{t�i�� i 'ting products
under th s evaluation. >>� Bow trrrr,
Locke So►den, P.E. is not owned, operated, or controlled by any company, manufacturer, or ` ij i orq) J* r this
report. �F
1
5 V Crimp
Fastener- #9-15 corrosion resistant w/sealing washers
24"coverage
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2017 Florida Building Code, Section 1507
Perimeter fastening: 6"o.c.
Main Field fastening 1 2"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel
MINIMUM 2 FASTENERS Fastener.-#10x 1"
AT LOCK SEAM Zinc Plated MTW
Pancake Head
) CUT 112 SHINGLE
ZEATE STAGGERED
ERN
DRIAN CRIMP
GLES
)
)
CRIMP SHINGLE
LOCK SEAM
t
) w
t �
O
t a
t w
c
9"EXPOSURE