Loading...
HomeMy WebLinkAboutEVALUATION( APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 1B-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 11 1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12-13 1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-15 1F-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 16-18 1F-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 19-21 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22-24 213 Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25-28 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 29-31 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 32-40 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 40 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 43 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-46 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47 56 CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 49 51) CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 49 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 50-52 613 Gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 53 6D Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53 7A Various Recover A 1 Bonded Insulation, Bonded Roof Cover 54-58 713 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 58 ' The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. d 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: SCA NAIED D Wood: Minimum 0.75-Inch penetration. By D Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. tljcVe C® D Structural concrete: Minimum 1-inch embedment Into pilot hole in accordance with fastener manufacturer's published installation instructions. u�$v 3. Unless otherwise noted, insulation may be any one layer or combination of polylsocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R20 for FL1654-R22 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58 15. Unless otherwise noted, refer to the following references for bonded base, olv or cao sheet aoolications. TABLE 1: POLYGLASS ROOF COVERS Reference Layer Material Application BP -AA Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II Hot Asphalt at 20-40 PI One or more plies Polyglass PI IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI (Base and Ply sheets, Asphalt- Ibs/square Note: Asphalt -applied sheets or Insulation shall not be a piled to oly fllm surfaced membranes. Applied) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II, Polyglass HT Base 650 PG350 at 1.5-2.0 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshleld SBS-CAI gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II SBS-CA2 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield Polyplus 35 at 1.5-2.0 gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex SBS-AA 56 Type ll, Polyglass HT Base 650 Hot Asphalt at 20-40 Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-G, (SBS, Asphalt -Applied) Ibs/square Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Note: Asphalt -applied sheets or insulation shall not be applied to poly flim surfaced membranes. Base Ply or Ply One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, ElastoflexS6, Elastoflex S6 Type II, Polyglass HT Base SBS-TA 650 Torch -Applied Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, (SBS, Torch -Applied) Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed) Base Ply One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Cap Ply Elastoflex SA P, Elastoflex 5A P FR, Polyreflect SBS-SA Self -Adhering Note: Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, (SBS, Self -Adhering) Elastobase (poly/sand) or Elastobase ( of /poi ). APP-CAI Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal] square APP TA , Base Ply or Ply One or more plies Polyglass APP Base, Polyflex, Polybond Torch -Applied Polyflex, Polyflex G, PolyflexG FR, Pol bond, Pol bond G, Polyfresko G, Polyfresko G FR (APP,Torch-Applied) Cap Ply t i 16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. D PG200 Non Fibered Roof Coating; D PG300 Flbered Roof Coating; D PG600 Nan-Flbered Aluminum Roof Coating; D PG650 Flbered Aluminum Roof Coating; D PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; D PG70005 (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only); D PG800 Asphalt Emulsion Roof Coating; D Polyplus 60 Premium Nan-Fibered Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating; D Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 25; ➢ Polybrlte 70Q$ (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15.Oj (for granule -surfaced APP or SBS only); D Polybrlte 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report P9290.02.08-R20 for FL1654-1122 Certificate of Authorization N9503 67' EDITION (2017) FBC NON-HVH2 EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 3 of 58 TABLE 1F-2: WOOD DECKS- NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No, Deck (Note 1) (Psf) Type Fasten Attach Base Ply Cap SELF -ADHERING BASE PLY: W-136 Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast 914 12-Inch o.c. In 4-Inch lap and 12-Inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- 52.5" inch plywood P Yw (poly -film to (p Y P) orTrufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows () q Y P gg TA APP-TA W-137 Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. In 4-Inch lap and 12-Inch o.c. in two Polyflex SA Base APP-TA -52.5* Inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows W-138 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-Inch o.c. in 4-inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- 60.0` Inch plywood (poly -film top) (2), equally spaced, staggered center rows TA, APP-TA W-139 Min. 19/32- Elastobase, Elastobase P OM G Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-Inch lap and 12-inch o.c, in two Polyflex SA Base APP-TA -60.0' Inch plywood (poly -film top) (2), equally spaced, staggered center rows TABLE 1G: WOOD DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Joint Treatment Base Ply Ply Cap Ply No. W-141 Min. 15/32- Inch plywood (Optional) PG100 None Polyflex SA Base (Optional) APP-TA APP-TA -90.0 W-142 Min. 15/32- PG100 None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS 97 5 Inch plywood TA, APP-TA TA, APP-TA Min. 15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- Inch plywood (Optional) PG100 (Optional) place to create continuous bond. Elastoflex SA V FR Base TA, APP-TA TA, APP-TA 97.5 W-144 Min. 15/32- WB-3000 None SBS-SA (Optional) SBS-SA, APP-SA, SBS- -105.0 Inch plywood TA, APP-TA W-145 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- -135.0 Inch plywood place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA W-146 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled Into Polyflex SA Base (Optional) APP-TA APP-TA -135.0 inch plywood place to create continuous bond. Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report P9290.02.08-R20 for FL1654-1122 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 21 of 58