HomeMy WebLinkAboutEVALUATION( APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
Deck
Application
Type
Description
Page
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
1B-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
1B-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
1C
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
11
1D
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-13
1E
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
1F-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
1F-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
19-21
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22-24
213
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
32-40
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47
56
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
48
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
51)
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
49
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
49
6A
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
50-52
613
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
52
6C
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
53
6D
Gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
53
7A
Various
Recover
A 1
Bonded Insulation, Bonded Roof Cover
54-58
713
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
58 '
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. d
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: SCA NAIED
D Wood: Minimum 0.75-Inch penetration. By
D Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. tljcVe C®
D Structural concrete: Minimum 1-inch embedment Into pilot hole in accordance with fastener manufacturer's published installation instructions. u�$v
3. Unless otherwise noted, insulation may be any one layer or combination of polylsocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover.
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58
15. Unless otherwise noted, refer to the following references for bonded base, olv or cao sheet aoolications.
TABLE 1: POLYGLASS ROOF COVERS
Reference
Layer
Material
Application
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II
Hot Asphalt at 20-40
PI
One or more plies Polyglass PI IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
(Base and Ply sheets, Asphalt-
Ibs/square
Note:
Asphalt -applied sheets or Insulation shall not be a piled to oly fllm surfaced membranes.
Applied)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II, Polyglass HT Base 650
PG350 at 1.5-2.0
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshleld
SBS-CAI
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
Polyplus 35 at 1.5-2.0
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex
SBS-AA
56 Type ll, Polyglass HT Base 650
Hot Asphalt at 20-40
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-G,
(SBS, Asphalt -Applied)
Ibs/square
Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly flim surfaced membranes.
Base Ply or Ply
One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, ElastoflexS6, Elastoflex S6 Type II, Polyglass HT Base
SBS-TA
650
Torch -Applied
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
(SBS, Torch -Applied)
Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
Cap Ply
Elastoflex SA P, Elastoflex 5A P FR, Polyreflect
SBS-SA
Self -Adhering
Note:
Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein,
(SBS, Self -Adhering)
Elastobase (poly/sand) or Elastobase ( of /poi ).
APP-CAI
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
gal] square
APP TA , Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
Torch -Applied
Polyflex, Polyflex G, PolyflexG FR, Pol bond, Pol bond G, Polyfresko G, Polyfresko G FR
(APP,Torch-Applied) Cap Ply
t
i
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
D PG200 Non Fibered Roof Coating;
D PG300 Flbered Roof Coating;
D PG600 Nan-Flbered Aluminum Roof Coating;
D PG650 Flbered Aluminum Roof Coating;
D PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
D PG70005 (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only);
D PG800 Asphalt Emulsion Roof Coating;
D Polyplus 60 Premium Nan-Fibered Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating;
D Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 25;
➢ Polybrlte 70Q$ (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15.Oj (for granule -surfaced APP or SBS only);
D Polybrlte 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report P9290.02.08-R20 for FL1654-1122
Certificate of Authorization N9503 67' EDITION (2017) FBC NON-HVH2 EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 3 of 58
TABLE 1F-2: WOOD DECKS- NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
Base Sheet
Roof Cover
(Note 15)
MDP
No,
Deck (Note 1)
(Psf)
Type Fasten Attach
Base Ply Cap
SELF -ADHERING BASE PLY:
W-136
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast 914
12-Inch o.c. In 4-Inch lap and 12-Inch o.c. in two
SBS-SA
SBS-SA, APP-SA, SBS-
52.5"
inch plywood
P Yw
(poly -film to
(p Y P)
orTrufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
() q Y P gg
TA APP-TA
W-137
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-inch o.c. In 4-Inch lap and 12-Inch o.c. in two
Polyflex SA Base
APP-TA
-52.5*
Inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
W-138
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
12-Inch o.c. in 4-inch lap and 12-inch o.c. in two
SBS-SA
SBS-SA, APP-SA, SBS-
60.0`
Inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
TA, APP-TA
W-139
Min. 19/32-
Elastobase, Elastobase P
OM G Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c. in 4-Inch lap and 12-inch o.c, in two
Polyflex SA Base
APP-TA
-60.0'
Inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
TABLE 1G: WOOD DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER
System
Deck (Note 1)
Primer
Roof Cover (Note 15)
MDP (psf)
Joint Treatment
Base Ply
Ply
Cap Ply
No.
W-141
Min. 15/32-
Inch plywood
(Optional) PG100
None
Polyflex SA Base
(Optional) APP-TA
APP-TA
-90.0
W-142
Min. 15/32-
PG100
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS
97 5
Inch plywood
TA, APP-TA
TA, APP-TA
Min. 15/32-
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
Inch plywood
(Optional) PG100
(Optional)
place to create continuous bond.
Elastoflex SA V FR Base
TA, APP-TA
TA, APP-TA
97.5
W-144
Min. 15/32-
WB-3000
None
SBS-SA
(Optional)
SBS-SA, APP-SA, SBS-
-105.0
Inch plywood
TA, APP-TA
W-145
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-135.0
Inch plywood
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
W-146
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled Into
Polyflex SA Base
(Optional) APP-TA
APP-TA
-135.0
inch plywood
place to create continuous bond.
Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report P9290.02.08-R20 for FL1654-1122
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 21 of 58