HomeMy WebLinkAboutPROJECT SUMMARYProject Summary Date: Job: : -- En fire House By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772 466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM_ •ect Information For: WYNN DEDVELOPMENT, FT. PIERCE, FL Notes: Design • • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 24753 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load_ Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318, Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool" (none) Area (ft2) 1446 IZ% Equipment latent load 5521 Btuh Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating.input Sensible cooling 24360. Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 . °F Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160. cfm . Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ely ne, copy wrightsoft` 2017-Apr-11 09:29:38 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick CialcMDoCUments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N wrightsoftRight-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email; QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 E)qosed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) . Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 L- G` 13Ar4ocs 4A5-2om 0.143 0.770 , n n 4:00 21.56 . 2.55 19.31 503 38 465 0 1862 815 1184 730 72 0 72 "' 0 288 0 : 183 . " 0 13A-4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 11 1A-clom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 W 13AAocs 0.143 se 4.00 2.55 34 34 136 86 0 - 0 .0 0 t-G 13AAocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 1Aclom 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 13AAocs 0:143 w 4.00 2.55 310 237 949 603 104 72 288, 183 1A-clam 1.270 w 35.56, 55.21 32 2 1140. 1770 32 2 1140 • 1770 4A5-2om : .0. 70 w 21.56 19.31 41 " 41 880 .. 788 0 .0 0 0 • P 12C-0sw 0.091 2.55 1.28 192 192 489 246 0 0 0 0 C , . . ;16A:30md 0.032 - 0,90; 2.32 1446 . 1446 1295 3354 _ 297 ., 297 .. " 266 689 F . 22A-tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal (lines 6 to.13) 17848 17520 5053 4925 Less wdemal load 0 0 0 0 14 Less.transfer Redistribution Subtotal 0 0 17848 0 0 17520 0 0 5053 0 0 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load Air required (cfm) 23503 1160 26056 1160 -T 1 6328 28 7325 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A- -Fp- wrightsoft- 2017-Apr-11 09:29:38 AEUk Right -Suite® Universal 2017 17.0.14 RSUD8101 Page 1 ...ulck CaicslDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wriglhtsoft° Right-M Woeksheet Job: Entire House Date' ey: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS !AOL.COM 1 Room name WIC KITCHEN 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 ft2 172.0 ft2 Ty Constriction U-value Or HTM Area . (ft2) Load . Area (ft2) Load number (Btuh/ft22F). (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A4acs>,: 0143 :r` 4.00 2.55 0 0 , 0 r= 0 0 10 4A52om, 0.7-/0.7h 21.56 19.31 0 0. _ 0'. 0. 0 0 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 1 11130 0.390 a 10.92 11.31. 0 0 0 0 0 0 0 0 W ,- 13A4ocs 0.143; se • 4.00 2i55 0 0 0. 10 0 0 : ' 0 0 VIl 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 -G 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-4ocs 0.143 : w• 4.00 2.55 0 .0 0 .0 0 0 A 0 lA-clom 1.270 - w 35.55 " 55:21 0 0 0. 0 0- 0 0. 0 AA5.26iii 0.770 w 21.56 19.31 0. 0 0 0 6. 0. 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C ., ; ..16A=30m& .. 0 1032 - - :0:90 2.32 ' 54 :.. 54 48, , 125 :.. .172 . -': 172 ' .::. 154 .. ',. .399 F 22A-tpI 0,989 - 27.69 0.00 lz 54 0 0 0 172 0 0 0 12 a) Infiltration 0 0 0 b) Room ventilation 0 0 1. 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less ekemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49%1 100 1126 Total room load 1 64 174 418 3437 Air required (cfm) 3 8 21 153 .Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A� wrigl itst t. Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ...uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 2 -rp- wr 9 RihW@ ghtsoftgWorksheet 6°b Entire House Date: By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 2 Exposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heaticool 8.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft2 1.0 x 203.5 ft 203.5 ft2 Ty Construction LI-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2-"F) (Btuhlft2) or perimeter (ft) (Btuh), or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool 6 yJ �Gw 13A.4ocs 4A5 tom 13A-4ocs 6.143. 0.770 0.143 n = n a A00 21.56 4.00 - Z55 19.31 2.55 40 0 0 40 6 0 160 0 0. '102 .0 0 128 ` 0 80 928 " : 0. 56 513 0 225 326 0 143 VI/ 11 {L-(p' 1A-clom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 24 0 2, 0 848 0 2082 0 W t-G 13A4ocs 13A4ocs IA-clom 0.143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 34 32 0 -34 32 0 136 128 0 86 81 0 VE13A4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1.270 -, w 35:56 . 55.21 0 0 0. 0 0 0 0 0 P C:; 4A5.2om 12C-0sw 16A30md .0.770 0.091 0.032 w .- - 21i56 2.55 :0.90 19.31 1.28 2.32 0 0 45 0 0 . 45 0 0 40; .0 0 104, 6 0 - . 204 0 0 204 0 0 ` 182 6 0 - 472 F 22A tpl 0.989 - 27.69 0,00 45 5 138 0 204 34 946 0 6 c)AED excursion _16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 1 230 0 Subtotal (lines 6 to 13) 425 214 3571 3498 14 15 Less external load Less transfer Redistribution . Subtotal Duct loads 32% 49% 0 0. 0 425 135 0 0 0 214 104 32% 49% 0 0 0 3571 1131 0 0 0 3498 1704 Total room load Air required (cfm) 560 28 318 14 4702 232 5203 232 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wcigl7tsOft" Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:age 3 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 3 + wrightsoft Right-M Worksheet Job: Entire House Date: sy: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft. heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 Ty . Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-'F) (Btu 2) or perimeter (ft) (Btuh), or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 13A flocs' 0143 W 4 00 2:55 0 0 0 0 255 ; 217 869 552 _4A5-tom ; 0.770 n . 21:56 ; :.19.31 0 - 0 0 0 , 38 - 0 815 ,.. 730 W 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 iL---0G 1Aclom 11DO 1.270 0.390 e' a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 W : , V+/ "LG 13A�4ocs - 13A-4ocs 0.143 0.143 'se s 4.00 4.00 . 2.55 2.55 0 48 0 48 0 192 0 122 0 0 0 0 •.0: 0 0 0 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ocs 0.143 w 4.00 2.55 0 0 0 :0 206 165 661 420 1A�1om. 1.270 - w • 35.56 . 65.21 0 -0 0 : - 0 0 : 0 0 0 P 4A5-2om 12C-0sw 0.770 0.091 w - 21.56 2.55 19.31 1.28. 0 56 0 56 0 143 0. 72 41 0 41 0 880 0 788 0 C F ::16A 30.md..: 22AtpI 0c032 0.989 - : 0.90 27.69 . .232 0.00 : '.. 42 42 42 6 . - 38 166 . 97 0 :. - 526 526 :526 47 ;471 1302 7220 0 6 c)AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration b) Room ventilation 104 0 28 0 997 0 273 0 13 Intemal gains: Occupants @ 230 Appliances/other 0 0 0 2 460 0 Subtotal (lines 6 to 13) 643 298 5994 5112 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 32% 496% 0 0 0 643 204, 0 0 0 298 145 32% 49% 0 0 0 5994 1899 0 0 0 5112 2490 Total room load Air required (cfm) 846 421 443 20 7892 390 7602 338 Calculations approved byACCA to meet all requirements of. Manual J Sth Ed. C - wrightsoft- Right -Suite@ Universal 2017 17.0.14 RSUD8101 2017-Apr-11 09:29:38 .4'C�A Page 4 :uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N - wrightsoft' Right-J® Worksheet Eh re House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: By: 1 Room name FOYER M. BATH 2 Exposed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool. 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 50.0 ft 50.0 ftz 7.0 x 8.0 ft 56.0 ftz Ty Construction U-value Or HTM Area (ft Load Area (ft-) Load number ( � ) Btuh/ft °F (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool 6 G 13A-4ocs 0 143 -n' 4.00 - 2:55 : 8 . 8 32 20 0. '0 . ."o ' • 0 4AS-2om. ° : 13A-4ocs .0.776 0.143 ri a 21.56 4.00 -, 19.31 2.55 0 48 0 27 0 108 0 69 0 0 0. 0 0. 0 0 0 W 11 L--_Gp 1A-clom 11D0 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 w t13A4ocs .13A-4ocs 1Aclom 0.143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 64 7 0 57 7 0 228 247 0 145 241 -C 13A4ocs AA-clonn 0.143 1.270 w w 4.00 35.56 2.55 55.21 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 0. 0 4A5-2om - 12C-0sw ;16A-30md- 22A tpl 0.770 0.091 . 0.032 0.989 w - - 21.56 2.55 OM.2.32 27.69 1931 1.28 0.00 0 72 .50 50 0 72 50 7 0 183 45 194 0 92 _ 116 0 0 0 .56 56 0 0 .56 8 0, 0 50, 222 0 0 130 0 P C.. F 4. 6 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration b) Room ventilation 121 0 33 0 138 0 38 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 913 529 885 516 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 32% 49% 0 0, 0 913 289 0 0 0 529 258 32% 49% 0 0 885 280 0 0 516 251 Total room load Air required (cfm) 1202 59351581 787 1166 768 34 Calculations approved by_ACCA to meet all requirements of Manual J 8th Ed 1- +�_ wrightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 AC�A Page 5 ...ulck CaIcslDacuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N